Multifunctional Cycle Control Time Relay Module
Timer Trigger Delay Count Switch Board MOS Tube Control 10A 12V
Description:
Multifunctional time relay module, 5V~30V wide voltage power supply, MOS tube control output, no contact, little interference. Control capability up to 10A. There are as many as 31 working modes to meet various testing and automatic control applications, and the delay time is adjustable from 0.01 seconds to 999 minutes. The trigger port can be triggered by a voltage signal, or it can be triggered by a button.
Parameters:
Power Supply Voltage: DC 5V~30V
Trigger Terminal Voltage: DC 3.3V~30V (It can also be triggered by a button)
Max Control Voltage: 10A
Module Size: 63x42x14mm (L*W*H)
Instructions For Use:
Press and hold the S1 key for 0.5 seconds, the display will show P-xx, and press the S2 and S3 key to change the working mode.
After selecting the working mode, short press the S1 key to enter the A time setting, and the display shows Axxx. At this time, press the S2 key or S3 key to modify the A time parameter. Short press the S2 and S3 keys to increase or decrease by 1, Long Press the S2 and S3 key to increase or decrease by 10 quickly, press S4 key to set the position of the decimal point.
After setting A time, press S1 key again to enter B time setting, the display shows Bxxx, At this time, press S2 key or S3 key to modify the B time parameter, short press S2 and S3 key to increase or decrease by 1, Long Press the S2 and S3 key to increase or decrease by 10 quickly, press S4 key to set the position of the decimal point.
After setting B time, press S1 key again to enter C time setting, the display shows Cxxx, At this time, press S2 key or S3 key to modify the C time parameter, short press S2 and S3 key to increase or decrease by 1, Long Press the S2 and S3 key to increase or decrease by 10 quickly, press S4 key to set the position of the decimal point.
After setting the C time, press the S1 key again to enter the D parameter setting. The D parameter is to set the cycle times parameter, the range is 1~999 times. After setting the D parameter, press the S1 key for the last time to exit the setting state and save all parameters.
The Meaning Of The Decimal Point Position:
Ax.xx The decimal point is in the hundreds place, and the time range is 0.01~9.99 seconds
Axx.x The decimal point is in the tens place, and the time range is 0.1~99.9 seconds
Axxx. The decimal point is in the ones place, and the time range is 1~999 seconds
Axxx No decimal point, time range is 1~999 minutes
Turn Off The Display: In the non-setting state, press the S4 key to turn off the display, and press it again to turn on the display.
Operating Mode:
P-01: The relay is disconnected after power-on or triggered, and the relay is operated after a delay of time A .
P-02: The relay is operated after power-on or triggered, and the relay is disconnected after a delay of time A .
P-03: In inching mode, there is a signal to operate, no signal to disconnect.
P-04: In self-locking mode, the state of the relay is flipped once after each trigger.
P-05: After triggering, the relay will operate and stop after a delay of time A. During the delay period, it cannot be triggered repeatedly.
P-06: After triggering, the relay will operate and stop after a delay of time A. Repeated triggering during the delay period will restart the timer.
P-07: After triggering, the relay will operate and stop after a delay of time A. Repeat triggering during the delay period, and the time will accumulate.
P-08: After triggering, the relay will operate and stop after a delay of time A. During the delay period it can be stopped immediately by trigger again .
P-09: After triggering, the relay is operated, when the signal disappears, the delay will stops after delay time A, and the trigger restarts during the delay period.
P-10: Operate time A when power on, and then the disconnected time is time B, and the cycle is infinite.
P-11: When there is a continuous signal, the operate time is time A, and then the disconnected time is time B, and the loop is infinite, and the signal disappears and stops immediately.
P-12: Trigger once to operate A time, disconnect B time, infinite loop, trigger again to stop.
P-13: The relay will operate when power-on, the relay disconnects after triggering, and the relay operated after a delay of A time.
P-14: When there is a continuous signal, the relay will operate after the time A is exceeded, and the signal disappears and the relay is disconnected.
P-15: When there is a continuous signal, the relay is disconnected, and the relay is operated after the signal disappears for more than A time.
P-16: After the continuous signal exceeds the A time, the relay operates, and the relay disconnects after the signal disappears for more than the A time.
P_17: After a continuous signal exceeds the A time, the relay will operate. After the signal disappears, the relay is disconnected after the continuous signal exceeds the A time again.
P_18: Triggered, the relay operate after the time A is exceeded, and it is triggered again, and the relay is disconnected after the time A is exceeded.
P_19: There is a continuous signal that the relay will operate A time and then stops, and then if the signal disappears, the relay will operate A time and stops.
P_20: If there is a pulse signal (rising edge or falling edge), the relay stops, but there is no pulse signal, and the relay will operate after a delay of A time (continuous high level or continuous low level is considered to be no pulse).
P_21: After power-on, the relay will operate after a delay of time A, and stops after operate B time.
P_22: After triggering, the relay will operate after delay A time, and stops after operate B time.
P_23: When there is a continuous signal and the time exceeds A, the relay operate and it will stop when operate time exceeds time B.
P_24: After triggering, the relay will operate A time and then stops, and then counts the B time after the stop, and cannot be triggered again within the A+B time.
P_25: After triggering, the relay will operate A time and then stops, counts the B time, and then operate A time, then stops, and cannot be triggered repeatedly during this period.
P_26: Counting mode, triggered by a rising edge signal, each time a rising edge signal is detected, the value is +1, the maximum count is 9999, and the maximum frequency is 20Hz. Short press the S1 key to clear it.
P_27: Counting mode, triggered by a falling edge signal, each time a falling edge signal is detected, the value is +1, the maximum count is 9999, and the maximum frequency is 20Hz. Short press the S1 key to clear it.
P_28: Counting mode, triggered by rising edge signal, value +1, maximum count 9999, maximum frequency 20Hz, when the count value is equal to the D parameter, the relay is operated, the program stops, and it can be reset by short pressing the S1 key at any time.
P_29: Counting mode, triggered by rising edge signal, value +1, maximum count 9999, maximum frequency 20Hz, When the count value is equal to the D parameter, the program resets automatically after the relay operate the A time. Short press the S1 key at any time to reset.
P_30: After triggering, delay time A to operate (falling edge signal trigger), operate time B to turn off, count once, stop when the number of counts reaches parameter D, if there is a trigger (rising edge signal) during the time delay of A, it will reset.
P_31: After the power is turned on, it counts down for time C and then automatically triggers. After triggering, it will be operated after delaying time A, and disconnected after operating B time. It will count once, and when the number of counts reaches parameter D, it will start a new big cycle.
Packing List:
1pcs x Multifunctional Cycle Control Time Relay Module