Features

Universal AC input / Full range
Fully isolated plastic case
Protections: Short circuit / Over voltage
Constant current design (C.C. mode)
IP30 design
Class 2 power unit / Pass LPS
Isolation class II, no F.G.
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications
2 years warranty

General Specification

AC input voltage range 90~264VAC ; 127~370VDC
AC inrush current Cold start, 70A at 230VAC
Overload Range >105% rated output current
Protection Type Hiccup up mode, auto-recovery
Over voltage protection 110%~145% rated output voltage
Withstand voltage I/P-O/P: 3kVAC
Working temperature -30~+70°C (refer to output derating curve)
Vibration 10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes
Safety standards UL8750 approved; Design refer to IEC61347-1, IEC61347-2-13
EMC standards EN55015, EN61000-3-2 class A , EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
Connection Input UL rated, 18AWGx2C (15cm)
Connection Output UL rated, 20AWGx2C (15cm)
Dimension (LxWxH)(mm) 77x 40x 29