AC input voltage range |
90~264VAC / 1.0A |
AC inrush current (max.) |
Cold start, 65A at 230VAC |
Overload protection Range |
105%~150% rated output power |
Overload protection Type |
Hiccup mode, auto-recovery |
Over voltage protection |
105%~135% rated output voltage |
Setup, rise, hold up time |
1000ms, 30ms, 50ms at 230VAC input |
Withstand voltage |
I/P-O/P:3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC |
Working temperature |
-30~+60°C
|
Safety standards |
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved |
EMC standards |
EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, CNS13438, GB9254, FCC part15 class B |
Length of output cable |
100cm of UL1185, 16AWG for 5~15V; 180cm of UL1185, 18AWG for 18~48V |
Dimension (LxWxH) |
125x 50x 31.5 mm |
Standard DC plug |
P1J: 2.1ID x 5.5OD x11mmL, tuning fork type |