This complete fire door kit is perfect for HMO’s, Office, Public spaces where you need a fire door that can be operated using a pull handle one side and push plate the other. This also includes a double cylinder and keys. Which allows you to lock the door from either side using a key. This kit is ideal for corridors, passageways or office doors that can be locked. These kits have been purpose designed for either use on timber or steel doors. All products have been tested and are in accordance with fire ratings of at least up to 60 minutes for a timber doors and steel doors. 


Timber Fire Rated kit


1no - Door Closure - Briton 131 door closure, regular duty, Size 2-4, silver

1no - Pull Handle - D-Style Pull handle, 20mm Diameter x 300mm Centres, grade 304 Satin Stainless Steel.

1no - Push Plate - Push plate, 330mm x 76mm x 1.2mm, Satin stainless steel, Grade 430, radius corners, Linished edges, c/w fixings, drilled & countersunk 6 times.

3no - Hinges - Ball Bearing Hinge, Grade 13, Plain, Grade 304,102mm x 76mm 3mm, Non-Branded, Wood screws.

1no - Hinges Pads Pack - 101 x 30mm hinge pad to suit 102 x 76mm hinge, pack of 6no.

1no - Fire Exit Disc - FIRE DOOR KEEP SHUT SIGN, 76mm x 1.2mm thick, Blue & Natural, Drilled & Countersunk, bagged with 2 screws.

1no - Mini Teardrop Seal 7.5m coil- Mini silicone teardrop seal, 4.5mm thick x 10mm wide x 7.5 metre coil, self-adhesive backing.

1no – Mortice Dead Lock Case, 20mm Radius Forends, 60mm back set

1no – Lockcase Pads - Intumescent lock pack, 4-part to suit DIN standard lock case with 60mm backset.

1no – Cylinder – Euro Double cylinder, 70mm cylinder with keys

1no – Pair Escutcheon - Euro escutcheon, 53 x 4mm, stainless steel inner.


Timber Fire Ratings


Door closer tested to BS EN 1634-1:2000 2 hours on timber doors.Certifire approved No CF 5512 CE and ARCA marked to EN 1154-1996

Pull handles – On Timber doors are tested to EN 1634-1 for up to 120 minutes 

Push Plates – Push plates can be screwed fixed. Can be used without affecting the fire rating of a door.

Fire exit sign – Fire Exit Signs can be screwed fixed without affecting the fire rating of a door.

Hinges – Suitable for use on Timber fire doors up to 60 minutes, tested to EN1634-1

Hinge Pads – Use FS4004 type intumescent can be fitted to insulated timber  to provide up to 60 minutes integrity tested in accordance with BS EN 1634-1:2000

Mini teardrop – Can be included on insulated timber doors without detracting from their achieved fire performance to BS 476:22:1987. Suitable for use on timber doors up to 60 minutes. Also tested to BS EN1634-1 and 1634-3 for smoke and fire testing.

Lockcase – Manufactured in accordance with DIN 18251 and CE marked. Tested to BS EN 1364-1:2000. Timber insulated doors for up to 60 minutes

Lockcase Intumescent – Use FS4004 type intumescent can be fitted to insulated timber door sets to provide up to 60 minutes integrity tested in accordance with BS EN 1634-1:2000

Escutcheons – Assessed for integrity use on insulated timber doorsets for up to 60 minutes in accordance with BS EN 1634-1:2000

Cylinder – fire tested to 60 minutes, FD30/60


Steel Fire Rated Kit


1no - Door Closure - Briton 131 door closure, regular duty, Size 2-4, silver

1no - Pull Handle - D-Style Pull handle, 19mm Diameter x 300mm Centres, grade 304 Satin Stainless Steel.

1no - Push Plate - Push plate, 330mm x 76mm x 1.2mm, Satin stainless steel, Grade 430, radius corners, Linished edges, c/w fixings, drilled & countersunk 6 times.

3no - Hinges - Ball Bearing Hinge, Grade 13, Plain, Grade 304,102mm x 76mm 3mm, Non-Branded, Machine screws.

1no - Fire Exit Disc - FIRE DOOR KEEP SHUT SIGN, 76mm x 1.2mm thick, Blue & Natural, Self-adhesive backing.

1no - Mini Teardrop Seal 7.5m coil- Mini silicone teardrop seal, 4.5mm thick x 10mm wide x 7.5 metre coil, self-adhesive backing.

1no – Mortice Dead Lock Case, 20mm square Forends, 60mm back set

1no – Cylinder – Euro Double cylinder, 70mm cylinder with keys

1no – Pair Escutcheon - Euro escutcheon, 53 x 4mm, stainless steel inner


Steel fire ratings


131-SES – Door closer tested to BS EN 1634-1:2000, 4 hours on steel doors. Certifire approved No CF 5512 CE and ARCA marked to EN 1154-1996

Pull handles – On steel doors the pull handle are tested to BS EN 1634-1:2014 for up to 240 minutes

Push Plates – Push plates can be screwed. Can be used without affecting the fire rating of a door

Fire exit sign – can be adhesive-fixed, without affecting the fire rating of a door

Hinges – Suitable for use on Steel fire doors up to 240 minutes, tested to EN1634-1

Mini teardrop – Can be included on uninsulated steel doors without detracting from their achieved fire performance to BS 476:22:1987. Suitable for use on steel doors up to 240 minutes. Also tested to BS EN1634-1 and 1634-3 for smoke and fire testing

Lockcase – Manufactured in accordance with DIN 18251 and CE marked. Tested to BS EN 1364-1:2000. Timber insulated steel doors for up to 240 minutes

Escutcheons – Assessed for integrity use on uninsulated steel doorsets for up to 240 minutes in accordance with BS EN 1634-1:2000

Cylinder – Fire tested to 240 minutes