ICU Patient Monitor 6 parameter Vital Sign ECG NIBP SPO2 Pr ,Promotion
                

Introduction 
Introduction
The monitor has abundant monitoring functions and is used for  monitoring of adult, pediatric and neonate. User may select different parameter  configurations according to different requirements. It displays real-time data  and waveform by 8'' TFT color LCD, and up to 8-channel waveform and all  monitoring parameters can be displayed simultaneously. 48mm thermal printer is  optional. In addition, it can be connected to the central monitoring system via  wired/wireless network so as to form a network monitoring system.
This  device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual-  channel TEMP, etc. It integrates parameter measurement module, display and  recorder in one device to form a compact and portable equipment. At the same  time, its built-in replaceable battery provides convenience for patient  moving.

Functions
Standard  parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECG   Heart  rate(HR)
      ECG waveform
      Arrhythmia and ST-segment  analysis
2)RESP   Respiration rate(RR)
      Respiration  waveform
3)SpO2   Oxygen saturation(SpO2)
      Plethysmogram(PLETH)  waveform
      Pulse rate(PR)
      Bar graph
4)NIBP   Systolic  pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP   T1, T2,  TD
It has abundant functions, such as audible and visual alarm, trend data  storage and output, NIBP measurement, alarm event marking and drug concentration  calculation, etc.

Features
1)8'' TFT color LCD,  multi-language interface(Simplified Chinese, Traditional Chinese, English,  French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian,  Kazakhstan, Polish, Czech).
2)Fanless design, quiet, energy-saving and clean,  which reduces the possibility of cross-infection.
3)All-round monitor for  adult, pediatric and neonate.
4)With standard interface, OxyCRG, trend chard,  big character interface and view bed, convenient to observe.
5)Waveform,  parameter color and location can be set optionally.
6)Operation mode: keys  and buttons.
7)Display up to 8-channel waveform on one screen.
8)Display  7-lead ECG waveform on one screen, and with ECG step function.
9)Adopt  digital SpO2 technology, anti-motion and anti-ambient light interference, and  measurement can be performed under the circumstance of weak filling.
10)HRV  analysis function.
11)NIBP measurement mode: Manual/AUTO/STAT, storage for  4800-group NIBP data.
12)Review for 71 alarm events of all parameters and 60  arrhythmia alarm events.
13)Drug concentration calculation and titration  table functions.
14)Print trend table data with one-key.
15)Connect to  Central Monitoring System by WiFi or wired mode.
16)AC/DC, built-in  rechargeable lithium battery achieve uninterrupted monitoring.
17)Anti-high  frequency surgical unit, defibrillation-proof(special leads are  necessary).

Performance
▲ECG
Lead mode: 3-lead or  5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead,  2-channel
3-lead, 1-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,  40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and  alarm range: 15~350bpm
Accuracy: ±1% or ±1bpm, whichever is greater
Alarm  accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement  and alarm range: -2.0mV~+2.0mV
Accuracy: -0.8mV~+0.8mV  ±0.04mv or ±10%,  whichever is greater
Other range: unspecified
Arrhythmia analysis:  ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY,  BRADY, MISSED BEATS, PNP, PNC
Pacemaker: yes
RESPIRATION
Method:  R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range:  0~150rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy:  ±3 rpm
Apnea alarm: 10~40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25  mm/s
▲NIBP
Method: Oscillometry
Mode: Manual/AUTO/STAT
Measurement  interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960  minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm  range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3  mmHg
Measurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal  standard deviation: 8mmHg
Over-pressure protection:
Adult mode: 297±3  mmHg
 Pediatric mode: 240±3 mmHg
 Neonatal mode: 147±3  mmHg
▲SpO2
Measurement and alarm range: 0 ~ 100%
Resolution:  1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%: unspecified
PR
Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2  bpm or ±2%, whichever is greater
TEMP
Channel: dual-channel
Measurement  and alarm range: 0 ~ 50℃
Resolution: 0.1 ℃
Accuracy: ±0.1  ℃
▲EtCO2
Method: Sidestream or Mainstream
Measurement range for CO2: 0  ~ 150mmHg
Resolution for CO2:
 0.1 mm Hg: 0 ~ 69 mm Hg
 0.25 mm Hg: 70  ~ 150 mm Hg
Accuracy for CO2:
 0 ~ 40 mm Hg: ±2 mm Hg
 41 ~ 70 mm Hg:  ±5%
 71 ~ 100 mm Hg: ±8%
 101 ~ 150 mm Hg: ±10%
AwRR range: 2~150  rpm
AwRR accuracy: ±1 rpm
Apnea alarm: yes
IBP
Channel:  dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measurement and  alarm range: -10~300 mm Hg
Resolution: 1 mmHg
Accuracy: ±2% or 1mm Hg,  whichever is greater
Power supply:100-240V~, 50/60Hz
Safety  classification: Class I, type CF defibrillation-proof applied  part

Accessories
Adult  fingertip SpO2 probe (5-pin)
Adult NIBP cuff
NIBP extension tube
ECG  lead cable
ECG electrode
Temperature probe
Power cord
User Manual

Physical  characteristic
Dimension: 235 mm(L) × 141 mm(W) × 222  mm(H)
Weight: 2.5 Kg


Buy safe products

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.

The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved

International Buyer--Please note:

Import duties,Taxes are not included in the item price.These charges are buyers' responsibility


We are the manufacturer of medical equipment for 17 years, the following are our main products:

ECG /  ECG holter   EEG / EEG Holter      B-ultrasound

Patient Monitor      Fetal doppler             Fetal Monitor 

Spo2 Monitor          Stethoscope              Medical Image....

Agent in the world!

We are look for partners in the world now!

Do you want  to become our agent in you conutry?

Join US!

Skype:xuebox3

contec.med.mary at hotmail.com

               
           
       
       
   

Only English User Manual,Please contact us if you need other language version.thank youibay365