This is Wi-Fi Wireless 8 channel SPDT relay kit (board) for remote management and control with Virtual Serial Port, TCP/IP, Web, HTTP API, Telnet and serial commands access. It has 8 SPDT Relays, 8 digital inputs (0-3.3V), 8 analog inputs (0-2.048V) and one UART port. Inputs can be adjusted to control relays (standalone work). Also inputs of one controller can control outputs of another over the LAN/WAN (box-to-box mode). It can send E-mails on inputs change as well. Suitable for remote control, home automation, data acquisition, sensor processing, alarm systems, PLC applications.Now with free Android and iOS mobile App!
Features
The auction includes
Application Examples
Instructions
Bellow is given shortcut for instructions how to connect the KIT or only DAEnetIP3 - WX for first time to Wi-Fi router. In the user's manual are shown the rest connection types.
Please pay attention that:
We recommend to use this 12VDC Power Supply Adaptor (SYS1357-2412) that may be found also in our store. Please contact with us if you have questions. We sell the adaptor with one of the AC plugs for: USA, UK, EU, AUS.
Note the Power adapter is not included in the auction, we just recommend to use it with the dvice!
It is sold separately. You may find it in our store!
Schematics
I/O Ports
The I/O controller has many modes for its inputs/outputs and all of them can be configurated by the user. The controller allows for example analog/digital inputs to control digital outputs, digital outputs to be switched based on 2 events per day (using build in Real Time Clock), generating pulses, timers and so on. You can refer to the user manual for more info.
16 Digital Outputs (Port A)
DAEnetIP3 has 16 digital outputs working in 19 different modes. However the relay bord has only 8 relay outputs. So to set the relays you need to change PortA.0 - PortA.7. Relay1 is connected to PortA.0, Relay8 to PortA.7. On the PCB this is marked as PortA_1. When the output level is 0, the relay is OFF. When it is 1, the relays is ON.
8 Digital Inputs (Port B)
DAEnetIP3 has 8 digital inputs. They work with +3.3V logic (Low level is 0V, high level is 3.3V). They work in 3 different modes. When the controller digital inputs pins are not connected the pins are in high level (there is connected pull up resistor 10K to each digital input). The input may be tracked only, may control some PortA digital output (this means the relay board also) by rising/falling edge or it may control even output from another DAEnetIP3 controller (Box-To-Box).
8 Analog Inputs (Port C)
DAEnetIP3 has 8 analog inputs with 2.048 VDC reference voltage source and 10 bit resolution. The inputs can be only monitored, can control some PortA digital output (this means the relay board also) by crossing threshold or it can control even output from another DAEnetIP3 controller (Box-To-Box). The inputs can also be calibrated softwarely according your hardware application so they can be retreived directly in desirable units (C,V,m...).This is so called linearization.
Mobile Apps
DAE-iModules iOS mobile App - 100% FREE
DAE-aModules Android mobile App - 100% FREE
Some useful information about DAE-iModules/DAE-aModules and DAEnetIP3:
Control via DRM Software
Denkovi Relay Manager (DRM) is multiplatform software for easy controlling all kinds of Denkovi relay boards (USB,SNMP,TCP/IP)
CAUTION! Using of Denkovi Relay Manager (DRM) Software with devices which are not manufactured by Denkovi Assembly Electronics LTD is not allowed!
The item is supported by DRM Software. DRM Software will hep you to save money for expensive software and time in programming. It allows you to switch ON/OFF your devices at particular date and time, turn ON/OFF the relays with pulses or control them via specific sequence. If you have ordered at least one of our relay boards from this list you may turn your PC in powerful automation tool.
How to access the ip controller
DAEnetIP3 Manager
Virtual Serial Port (Virtual Com Port)
DAEnetIP3 and all devices that are based on it may be accessed/controlled via Virtual Serial Port. In other words the the device in this auction may be accessed via COM Port RS232 commands from your computer because it will apear as COM Port:
Example commands and responses that are sent/received via the DAEnetIP3 VSP (COM Port). The serial address of DAEnetIP3 is 00.
All the commands are described in the user manual DAEnetIP3_UM.pdf
Web browser
DAEnetIP3 has built-in web server for configuration. All the parameters can be accessed via web browsers like Mozilla, IE and Opera. The pages for I/O ports are refreshed automatically. In this way it is possible to track all the I/O states in real time without manually refreshing the page. The web browser must support JavaScript.
The page below the text shows the page for the analog inputs. Their states are automaticaly refreshed each 2-3 seconds. The user doesn't have to click refresh button each time but just tracks the I/O changing values almost in real time (Ajax).
TCP/IP commands
DAEnetIP3 controller has possibility for access via TCP/IP socket. The user may connect with custom software to port (default is 1010) that is defined for socket based TCP/IP communication.
The protocol is not based on some standart, but it is developed especially for the DAEnetIP3 controller. The full description of the protocol may be found in the user manual. It is fully ASCII (strings).
The reason for creating such communiation way is that TCP/IP sockets are widely used in all programing languages.In this way you may create software for DAEnetIP3 without learning difficult and heavy protocols.
The controller supports RC4 encryption/decription for the TCP/IP socket comunication. This is security measure that gives you basic protection.
Another security option is IP address protection, that allows only one IP to access the DAEnetIP3 via Web, Socket and Telnet.
Example commands:
Set Digital Output 1 in Low state
Send: 00AS0=0;
Receive: 00AS0=0;
Get Analog input 1 value
Send: 00CV0=?;
Receive: 00CV0=512;
HTTP API commands
Bellow are shown example commands. Please note that there is HTTP API password (by default it is admin) to prevent unauthorized access.
Example commands:
send: http://your.ip.address/command.html?P=admin&ASG=?& (get the whole PortA status of DAEnetIP3)
receive: <!DOCTYPE html><html><body>ASG=0F0F;</body></html>
send:http://your.ip.address/command.html?P=admin&ASG=?&BVG=?&CV0=?& (send several commands at a time)
receive: <!DOCTYPE html><html><body>ASG=FFFF;BVG=0F;CV0=12;</body></html>
Telnet
DAEnetIP3 can be easily accessed via Telnet. Simple password protection mechanizm is provided. Note that Telnet is not secure protocol, so it is recommend using only in secure networks.
On the figure right to the text is shown how DAEnetIP3 controller with IP address 192.168.1.50 is accessed via Telnet with Windows XP.
Ofcourse these commands are only small part. The full list may be found in the documentation.
Serial Port
Each DAEnetIP3 controller may be accessed via UART serial communication. The protocol is given in the documentation. This is provided in case you need RS485 network for example accessed only with one IP address. Each controller has serial address, that is given in each packet sent to the server bridge from user software.
The figure right to the text shows how 3 DAEnetIP3 controllers are connected in serial network using UART <-> RS485 convertors (not included in the auction). The serial network may be accessed over LAN or WAN with user TCP/IP socket based software.
Useful Links
Please note that TFTP firmware upgrade is not anymore supported. From our experience we don't recommend to use it because it is unsafe and can damage your DAEnetIP3 controller. If you would like to upgrade your DAEnetIP3 device with the last firmware version, please contact with us and we will send you instructions.