This is kit of IP controller and card with 8 SPDT relays. It is for home automation, hobby and commercial projects. It allows you controlling electrical devices via LAN/WAN (Internet). Just connect the device into your local network and control it from another computer or android smartphone over the LAN or Internet. This IP relay board can be controlled from: Configuration utility - DAEnetIP2 Manager, web browser, command line, android smartphone application or Denkovi Relay Manager Software. We can provide also software examples for developers. Now with free Android and iOS mobile App!
Features
The auction includes
Application Examples
DAEnetIP2 Ports
|
Port JP3 (P3) |
Port JP4 (P5) - the relay board is connected here |
Port JP5 (P6) |
Port JP6 (System Port) |
||||||||
PIN # |
Bit |
FUNC |
DIR |
Bit |
FUNC |
DIR |
Bit |
FUNC |
DIR |
Bit |
FUNC |
DIR |
1 |
1 |
Free |
I/O |
1 |
Free |
I/O |
1 |
Free |
Ain |
- |
3.3V |
PWR |
2 |
2 |
Free |
I/O |
2 |
Free |
I/O |
2 |
Free |
Ain |
- |
3.3V |
PWR |
3 |
3 |
Free |
I/O |
3 |
Free |
I/O |
3 |
Free |
Ain |
- |
Reserved |
- |
4 |
4 |
Free |
I/O |
4 |
Free |
I/O |
4 |
Free |
Ain |
- |
Ping LED |
Out |
5 |
5 |
Free |
I/O |
5 |
Free |
I/O |
5 |
Free |
Ain |
- |
Reserved |
- |
6 |
6 |
Free |
I/O |
6 |
Free |
I/O |
6 |
Free |
Ain |
- |
Target RST |
Out |
7 |
7 |
Free |
I/O |
7 |
Free |
I/O |
7 |
Free |
Ain |
- |
Switch (RST) |
Out |
8 |
8 |
Free |
I/O |
8 |
Free |
I/O |
8 |
Free |
Ain |
- |
Switch (SCL) |
Out |
9 |
- |
GND |
PWR |
- |
3.3V |
PWR |
- |
Vref(+3.3V) |
PWR |
- |
Switch(SDA) |
In/Out |
10 |
- |
GND |
PWR |
- |
GND |
PWR |
- |
GND |
PWR |
- |
GND |
PWR |
Legend:
"Free"– the pin is free and defined for the user. | "XXXXXX" - the pin is reserved | "In" - the pin is input | "I/O" – digital input or output depending the settings | "Out" - the pin is output | "Ain"– analog input |
Note that the relay board is connected to JP4(P5) digital outputs port.
All the DAEnetIP2 I/O ports do not have any protection against overvoltage or reversed polarity.
For inputs, if the input voltage exceed 3.3V, the controller may be damaged. If you have questions how to use the I/O ports please contact with us or take a look into the manual.
Installation
Here are the steps (instructions) how to power on and connect the device directly to your computer (see this image). For router LAN connection (see this image)or Internet connection, please see in the user manual:
1.Connect the DAEnetIP2 controller with your computer via UTP crossover cable. (note that the device does not support AUTO MDIX). |
|
2.The flat ribbon cable connector must be fitted into to DAEnetIP2 IDC in this way |
|
3.Connect each "In" labeled wire into the referred screw terminal of the relay board. For example "In 1" wire goes into Relay 1 In screw terminal, "In 2" wire goes into Relay 2 screw terminal and so on. |
|
4.Connect the GND wire of the flat ribbon cable into the GND screw terminal of the relay board. |
|
5.Connect supply jack to DAEnetIP2. You will have to find suitable power supply adaptor. DAEnetIP2 minimal supply voltage is 7.5 VDC. The maximal voltage is 25 VDC. It is recommended the supply voltage to be 12 VDC but 24 VDC also will work. DAEnetIP2 doesn't have any protection against inverted supply voltage, so be careful. The middle pin of the power terminal is + Vcc (Center positive tip polarity) |
|
6.Connect the power wires to the relay board as it is shown on the image right to the text. It is possible to supply the DAEnetIP2 controller and relay board either with single either with 2 separate power supply sources. |
|
7.Now you can power on the whole kit (for example plug the supply adaptor into the electricity network) |
|
8.In case of success you have to see this when you power on the kit (the link led (top) is blinking and the bottom led by default shows the power on and it is constantly on) |
|
9.Check if the relay board power led is on constantly |
|
10. The kit in working condition | |
11.Open your LAN card network settings and save them, because next step is to change them. |
|
12.Your initial computer IP should be in the device network range. So it is recommend to be 172.16.100.1. Mask 255.255.0.0. Gateway 172.16.100.1. Change them. There is lot of info in the net how to do it (for example a good link is this one) |
|
13.Open web browser and type 172.16.100.2 – default username/password are “admin”/”admin” |
|
14.Now you can access all the parameters via your web browser or software on your computer. |
Default Settings
The controller has default settings, in case the access is lost. There are several steps for loading the default settings:
Default settings |
||
Parameter |
Value |
|
DHCP | Disabled | |
IP | 172.16.100.2 | |
Mask | 255.255.255.0 | |
Gateway | 172.16.100.1 | |
VLAN ID | 1 | |
VLAN mode | Disabled | |
Access MAC 1,2 | 000000000000 | |
SNMP access to IP | Enabled | |
SNMP listen UDP port | 161 | |
SNMP Read-only string | 000000000000 | |
SNMP RW string | private | |
SNMP/Web Access network IP | 172.16.100.1 | |
SNMP/Web Access network Mask | 0.0.0.0 (disabled) | |
Ping Timeout | 6 | |
Restart on incoming ping timeout | Disabled | |
Restart on remote IP timeout | Disabled | |
Remote monitor IP | 172.16.100.1 | |
I/O ports settings | P3,P5 - Outputs | |
Pull-Up/Pull-Down | All “pull-down” | |
Reset I/O ports on restart | Disabled | |
TFTP update | Enabled | |
TFTP Server IP | 172.16.100.1 | |
Broadcast Frames | Parse | |
Web Server | Enabled | |
Web Server TCP port | 80 | |
SNMP traps target host | 172.16.100.1 | |
SNMP traps community |
|
|
|
0/1023 (disabled) | |
Analog Events – Low, High, Acc | None | |
Web user/password | admin/admin |
DRM Software
Denkovi Relay Manager (DRM) is multiplatform software for easy controlling all kinds of Denkovi relay boards (USB,SNMP,TCP/IP)
CAUTION! Using of Denkovi Relay Manager (DRM) Software with devices which are not manufactured by Denkovi Assembly Electronics LTD is not allowed!
The item is supported by DRM Software. DRM Software will hep you to save money for expensive software and time in programming. It allows you to switch ON/OFF your devices at particular date and time, turn ON/OFF the relays with pulses or control them via specific sequence. If you have ordered at least one of our relay boards from this list you may turn your PC in powerful automation tool.
Mobile Apps
DAE-iModules iOS mobile App - 100% FREE
DAE-aModules Android mobile App - 100% FREE
Some useful information about DAE-iModules/DAE-aModules and DAEnetIP2:
DAEnetIP2 Manager
DAEnetIP2 Manager is configuration utility for Denkovi DAEnetIP2 controller
For download please use this link: download
Control via web browser
In order to access your DAEnetIP2 controller from browser, your web browser have to supports javascript. Just write the IP address of the controller in the address bar and you will see the page, which is integrated in the controller (it has small built in server). The default username/password are admin/admin.
I/O Ports control/monitor
Traps/P5 control. DAEnetIP2 can send traps if some analog input changes its level bellow/above some threshold (Low/High).
The same logic can be used for setting one of the digital outputs port - JP5 according analog input port JP6.
HTTP API Commands
DAEnetIP2 i/o lines can be controlled/accessed via HTTP API commands and basic access authentication is required to do that.
The digital outputs (P3 and P5) can be controlled by sending this HTTP command:
http://admin:admin[ at ]device.ip.address/iochange.cgi?ref=re-io&01=00&02=FF
admin:admin are the username:password
device.ip.address is the DAEnetIP2 IP address (by default it is 172.16.100.2)
01=00 is the state of P3 DO
02=FFis the state of P5 DO
For example:
http://admin:admin[ at ]172.16.100.2/iochange.cgi?ref=re-io&01=00&02=FF
The i/o states (P3, P5, P6) can be retreived by sending this HTTP command:
http://admin:admin[ at ]device.ip.address/ioreg.js
it will be received javascript file with several variables and one of them is:
var IO=new Array (0xFF, 0xFF, 0x80, 0x00AB, 0x0049, 0x0118, 0x014A, 0x012F, 0x003E, 0x0029, 0x01DD)
Bytes 0 and 1 are the digital I/O states (in hex format)
Bytes 3...10 are the Analog inputs values (in hex format)
For example:
http://admin:admin[ at ]172.16.100.2/ioreg.js
Command Line
Net-snmp is free command line utility for windows which allows you to execute snmp commands from command line, BAT files, BASH scripts or any other software that can execute external .exe file or commands from command line. The instructions file how to install net-snmp and example commands can be downloaded from here.
Software examples
For developers - we can provide examples and support for various platforms:
Java Example
labVIEW example
VB.NET Express example
Useful Links
Software Examples
Images
Please read before buy!