12V 10A ADJUSTABLE THERMOSTAT TEMPERATURE CONTROLLER SWITCH -50 TO +110 DEG C RANGE

• For temperature-based control of equipment in 12V environments eg. auto, camper, RV, MH, boat, marine, laboratory, industrial, etc.

FEATURE SUMMARY:

• -50 to +110 deg C operating range, for control of heating, boiling, cooling, refrigeration, freezing, fans, etc.

• Switched-relay operation – switch (terminals 'K0' & 'K1') is 'closed' at the temperature you 'Set', switch 'opens' again 2 deg C below 'Set' temperature, switch a load of up to 10A

• Simple three-button temperature configuration (from left to right: 'Set', 'Up', 'Down') press 'Set' to configure

• Probe temperature continually indicated during operation

• 'Set' temperature stored in memory, maintained if/when power is removed

• Simple screw-terminal access to switch contacts ('K0', K'1') and board power ('+12V', 'GND')

• Suitable for use with water tanks, refrigerators (eg. DIY/modified), chillers, boilers, steamers, industrial and other temperature-controlled systems.

• Resistance Thermometer Probe on 32cm cable

SPECIFICATIONS:

Temperature control range: -50 to +110 deg C
Resolution: 0.1 deg C in range -9.9 C to 99.9 C, 1 deg C outside range
Measurement Accuracy: 0.1 deg C
Control accuracy: 0.1 deg C
Hysteresis accuracy: 0.1 deg C
Refresh rate: 0.5 second
High temperature protection: 0 to 110 deg C
Board Supply Voltage: 12V DC
Measuring inputs: NTC (10K 0.5%) waterproof resistance thermometer (thermistor)
Switching relay: 12V 10A
Environmental requirements: -10 TO 60 DEG C, Humidity 20% - 85%
Dimensions: 50 x 40 x 15mm 
Board weight: 16g
Package weight: 23g

PACKAGE CONTENTS:

1 x 12V control board with LED display and three-button control
1 x resistance thermometer probe on 32cm cable
1 x instruction/spec sheet

APPLICATION NOTE

The factory default for this device is Cooling (C) mode. if you look at the chart on the back of the instruction/spec sheet, it describes – among its other features – how to configure the device for cooling or heating. For heating applications, press and hold the 'SET' button for five seconds to enter config mode, use +/- to select 'P0', press 'SET again briefly, then use +/- to switch from Cooling (C) to Heating (H) mode. Other features – such as temperature alarm and starting delay – are also described in the instruction/spec sheet.

Thanks for looking!