READ CAREFULLY ALL LISTING BEFORE BUYING!!!!!


This listing is for a Brand New, Model QDZH35G, 12V / 24V DC (Air Cooling) Compressor, R134a refrigerant, 55 - 95w, Refrigerator Fridge Freezer Marine Boat or for Solar Off Grid.

Direct low cost replacement for Danfoss BD35 DC compressors

***you may receive variation like on second picture, same compressor except for tubes that ares bended upward***


Suitable for water dispenser, small refrigerator, small freezer, wine cellar and other small cooling appliances used for car, ship and camping.

Electronic controller INCLUDED with purchase of compressor (like on picture)

Electronic controller AVAILABLE as spare parts in my store Click Here!


Perfect for AC to 12-24DC fridge conversion on R134A , this gas is inert and non-flammable so this is first choice for Boats and mobiles applications

Choose right compressor size and gas, Send me a message if you need help with that!

EXAMPLE: Don't fill R134A into a fridge designed for R600A, you will lose 50% of the cooling efficiency due to capillary tube size!


FULL SPECIFICATIONS AND INSTALLATION REFERENCE AVAILABLE HERE - MIRROR1 - MIRROR2


Model NO.: QDZH35G

Refrigeration Temperature Scope: -18℃~10℃

Shape: Cabinet Type (Open Outward)

Power Supply Type: DC

Type: Compressor Car Refrigerator

Voltage: 12V / 24V

Certification: CE

1) QDZH35G, DC series, use R134A refrigerant;

2) Voltage application 12V and 24V;

3) Cooling type: ST or FAN;

4) Application: Low Back Pressure, Middle Back Pressure;

5) Max cooling capacity 100W

6) power consumption in watt is 17 to 78w depends on rpm setting and back-pressure inside system


Model

Displacement (cm3)

Rotate Speed       (rpm)

Capacity  (W) 

COP

EER

Oil charge

Cooling Type

Power Supply

Certificate

-23.3ºC (ASHRAE)

W

Kcal/h

Btu/h

W/W

Btu/W.h

ml

QDZH35G

3.5

2000

60.0

51.9

204.6

1.08

3.68

160

FC

12/24V

(DC)

CE

2500

73.0

63.1

248.9

1.07

3.65

3000

86.0

74.4

293.2

1.06

3.62

3500

100.0

86.5

341.0

1.05

3.58



WIRING:

wiring diagram



Installation(Fig.1)
Connect the terminal plug from the electronic unit to the compressor terminal. Mount the electronic unit
on the compressor by snapping the cover over the screw head(1).

Power supply(Fig.1)
The electronic unit must always be connected directly to the battery poles (2). Connect the plus to + and
the minus to -, otherwise the electronic unit
will not work. The electronic unit is protected against reverse battery connection.For protection of the
installation, a fuse (3) must be mounted in the + cable as close to the battery as possible. 15A fuse for
12V and 7.5A fuse for 24V circuits are recommended.If a main switch (4) is used, it should be rated to a
current of min. 20A. The wire dimensions in Table. 2 must be observed. Avoid extra junctions in the
power supply system to prevent voltage drop from affecting the battery protection setting.

Battery protection(Fig.1)
The compressor is stopped and re-started again according to the decided voltage limits measured on the
+ and - terminals of the
electronic unit. The standard settings for 12V and 24V power supply systems
appear from Table. 3. Other settings (Table. 1) are optional if a connection which includes a resistor (9)
is established between terminals C and P.

Thermostat(Fig.1)
The thermostat (7) is connected between the terminals C and T. Without any resistor in the control circuit,
the compressor with electronic unit
will run with a fixed speed of 2,000rpm when the thermostat is
switched on. Other fixed compressor speeds in the range between 2,000 and 3,500 rpm can be obtained
when a resistor (8) is installed to adjust the voltage (v) of the control circuit. Resistor values for various
motor speeds appear from Table. 4.

Fan(optional,Fig.1)
A fan (5) can be connected between the terminals + and F. Connect the plus to + and the minus to F.
Since the output voltage between the terminals + and F is always regulated to 12V,a 12V fan must be
used for both 12V and 24V power supply systems.The fan output can supply a continuous current of
0.5A avg . A higher current draw is allowed for 2 seconds during start.

LED(optional,Fig.1)
A 10mA light emitting diode(LED)(6) can be connected between the terminals + and D. In case the
electronic unit records an operational error, the diode will flash a number of times. The number of flashes
depends on what kind of operational error was recorded. Each flash will last 1/5 second. After the actual
number of flashes there will be a delay with no flashes, so that the sequence for each error recording is
repeated every 3 minutes


---------------------------------------------------------------------------------------------