Model:CMS5100 vital signs patient monitor
Manufacture:CONTEC Medical Systems      

CMS5100 Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately measured.

Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family.

Features

■Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.

■Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.

Built-in rechargeable Li-polymer battery for uninterrupted monitoring.

■Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.

■With user-friendly interface.

■Display with 2.8'' (320×240) color TFT LCD and red and yellow highlight LED.

■Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.

■Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data.

■Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.

Performance

NIBP monitoring

■Measurement method: Oscillometry

■Measurement mode: manual/auto/continuous.

■Auto measurement interval: adjustable from 1 to 90 minutes.

■Resolution: 1mmHg.

■Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.

■Self-check function.

■Overpressure protection: double protection for software and hardware.

Range

Adult:

 Systolic pressure: 40mmHg~270mmHg

 Mean pressure: 20mmHg~235mmHg

 Diastolic Pressure: 10mmHg~215mmHg

Pediatric:

 Systolic pressure: 40mmHg~200mmHg

 Mean pressure: 20mmHg~165mmHg

 Diastolic Pressure: 10mmHg~150mmHg

Neonatal:

 Systolic pressure: 40mmHg~135mmHg

 Mean pressure: 20mmHg~110mmHg

 Diastolic Pressure: 10mmHg~100mmHg

Upper and lower limit of alarm

Adult:

 Systolic pressure: 40mmHg~270mmHg

 Mean pressure: 20mmHg~235mmHg

 Diastolic Pressure: 10mmHg~215mmHg

Pediatric:

 Systolic pressure: 40mmHg~200mmHg

 Mean pressure: 20mmHg~165mmHg

 Diastolic Pressure: 10mmHg~150mmHg

Neonatal:

 Systolic pressure: 40mmHg~135mmHg

 Mean pressure: 20mmHg~110mmHg

 Diastolic Pressure: 10mmHg~100mmHg

SpO2 monitoring

Continuous real-time measuring.

Adopt digital SpO2 technology, which has strong anti-interference capability.

Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.

Standard finger-clip probe for adult , binding probe for neonatal is optional.

SpO2 Measuring

Range: 35%~100% (Resolution: 1%)

Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.

Pulse Rate Measuring

Range: 30bpm~250bpm(Resolution: 1bpm)

Accuracy: ±2bpm or ±2%, whichever is greater.

Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown

correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.

Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

Accessories

A power cord

A power adapter

A SpO2 probe

An adult NIBP cuff

An extending tube for blood pressure

Physical characteristic

Dimension for product: 190(L)×162(W)×240(H)mm

Weight: 1.6kg

Dimension for packaging: 402(L)×228(W)×320(H)mm

Buy safe products

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.

The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved

Shipping:

1). We will ship within 1 business day after your payement ;ship from China warehouse by China Post 2-4 weeks Arrival.

2).We don't add taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties). Please find out as much as you can about your import taxes in your own country before bidding the item. You need to pay for the import duties in case that occurred for certain goods, or you may kindly give us some suggestions about that, we promise to do our best to help you!

About Warranty:

We guarantee new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective.

Return Policy:

If you receive a defective item which you want to return, please contact us within 5 days from the day you receive the item. 

All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.

We will refund the money to you when we get the return items. Or replace item for you free of charge.    


       
   

Only English User manual,Please contact us if you need other language version.ibay365