The load is powered at the range of 4-25.0V (the input polarity cannot be reversed, otherwise the product is permanently damaged and cannot be repaired), the LED will be flashing to remind current setting value, waiting for output. Press ON/OFF button, open output to start work.1. Adjust output current value. Turning the rotary control clockwise increases the value and anticlockwise decreases the value. According to the needs of the situation, the potentiometer can realize coarse adjustment or fine adjustment. The fine adjustment can be accurate to 0.01A.2, Adjust LED display statusPress “SET” to adjust the LED display status, default display output current value. Press “SET” button to display *.**A、**.*P、**.*V followed by recycling.3. Open or close load outputPress “ON/OFF” button, you can open or close load output4, Set load default boot status (open or close status, Factory default close status)
Press and hold “ON/OFF” button to set load default boot status freely. Press and hold “ON/OFF” button, if the LED will display “--ON”, as picture 4, the load will open output when power on next time; If the LED display”-OFF”, as picture 5 show, the LED will display current value flashing at last shutdown when power on next time, then press “ON/OFF” button to open output.
5, Set the load output recovery mode after protection removed.
Press and hold “SET” button, to set output recovery mode after protection removed. Press and hold “SET” button, if the LED will display “--ON”, as picture 4, and the protection was removed, the load will recover to work; If the LED display”-OFF”, as picture 5 show, and the protection was removed, the LED still show protection status, then press “ON/OFF ‘button, the display will display present setting current flashing, then press “ON/OFF‘ button again, the load recover to work.
NOTE: Please check the output current of power bank carefully. The current of the general power bank is generally small, so adjust smaller current when the load was used.
Application
Assist to measure Micro USB cable good or not
Assist to measure Type-C cable good or not
Assist to measure output current capacity of charger good or not
The usage of large batch ageing test at the charger factory
Package included:
1x Electronic Load Resistor USB Interface Discharge Battery Test 25W Tester
USB Load Resistor
Brand new and high quality.
It's normal when welding resistance may occur heated white smoke or odor phenomenon.
New products can freely be switched with a switch, very convenient and easy to use.
USB load resistance, is mainly to do discharge test, if the charger or mobile power supply output current is 2A, load meter power is 5V * 2A = 10W, if the output current is 1A, then the power load is 5V * 1A = 5W.
Switch and usb interface design.
Color: Green.
Rated Power: 5W-10W.
Technology: Ceramic Composition.
Resistance: 1A-2A.
Type: Fixed Resistor.
Size: 7.3cm x 1.8cm x 1.0cm.
More about item
usb mobile power load resistor power resistor aging resistance measuring current discharge resistor
Discharge resistors will become hot, the temperature at 80 ~ 85 ℃, please note that anti-scald.
You can easily test mobile power charging treasure, cell phone charger, USB power supply output current is standard, as long as the USB port to the resistance above the line. And can move the power and USB power adapter to do the aging test.
Package Included:
1 x USB Load Power Resistors Mobile Power Aging Resistance 1A 2A Module