laser therapy Apparatus

"Face-therapist M" APPOINTMENT OF STAFF

1.1 The device is intended for use as a laser source

the visible and infrared range of the spectrum with the aim of carrying out a wide range of procedures

medical rehabilitation, physiotherapy, balneology.

 The device provides:

- Speed ​​adjustment and power control of visible light;

- Speed ​​adjustment and power control infrared DC

radiation;

- Installation and monitoring procedures of time;

- Modulation of the radiation;

- Control of radiation dose.

2. SPECIFICATIONS

2.1 The length of the visible light wave "B" - 405-700 nm.

2.2 Wavelength "SP" infrared radiation DC - 701-1050 nm.

2.3 Power output "B" radiation - (5,10,15,20,25,30,35,40,45,50) mVt20%.

2.4 Output Power "FE" radiation - (10,20,30,40,50,60,70,80,90,100) mVt20%.

2.5 "IP" Output power laser radiation pilot not more than 1% mVt20.

2.6 Modulation of the "B" and "SP" radiation - Gts10 0.1-99.9%.

2.7 Radiation Time - 1s ... 99 min 59 sec.

2.8 Radiation Dose - Dzh20 0.01-99.99%.

2.9 Divergence of the radiation beam at the remote end of the handle - no more

0,5rad20%.

2.10 The unit operates on AC 50 Hz ± 1%, and a voltage

220 V ± 10%.

2.11 The power consumed by the device - no more than 10 watts.

2.12 The optical density of laser protective glasses - at least 3 Bel.

2.13 unit weight of not more than 1.5 kg, the unit weight (gross) - less than 2.5 kg.

2.14 Dimensions:

- An electronic unit, mm - 245 × 140 × 75;

- External handle, mm - 180 × 32 × 32;

- Cord length external handle not less than -1500 mm;

- The cord length is not less - 2000 mm.

5. DESIGN AND OPERATION OF THE MACHINE

5.1 Composition of the machine (Annex 3):

- An electronic unit (8);

- External handle (5);

The electronic unit comprises:

- Housing;

- Indicating subunit A1 (3);

- A2 subunit keyboard (4);

- A3 control subunit;

- A4 subunit supply.

5.2 Purpose of controls, display and control:

5.2.1 On the front panel:

 Buttons:

POWER - Δ increase,  decrease in laser power;

TIME - Δ increase,  temporary decrease in the value of the radiation parameters;

FREQUENCY - Δ increase,  decrease the value of the laser radiation modulation;

START - the inclusion of the radiation on the typed parameters;

STOP / CLEAR - in the primary pressing - off radiation in the secondary

pressed - Reset settings dialed.

 photodiode "CONTROL" (6) - Control of the radiated power;

 enable LED control light.

5.2.2 On the front side panel:

 Connector for external lever (2);

 Fuse F1A 250V

 Putting cord 220V 50Hz 10W (1).

5.2.3 On the side of the right pane:

 NETWORK switch (7) - switch unit ( "1"), off

unit ( "0").

5.3 Principle of operation

The operating principle of the device is based on the generation of laser radiation

"VRIP" semiconductor lasers and laser modules outrigger arms "BPB"

its output through optical connectors for periphery instrument for the purpose of

delivery of laser radiation to the site of the procedure.

Set operating modes and parameters of laser radiation by the buttons

SA1-SA9 A2 keyboard unit, which are displayed on the display unit and the display A1

served on the block A3 management, providing the parameters of the laser control

radiation. A4 a power supply for supplying stabilized voltages to

blocks, boards, and elements of the apparatus. You can control power

radiation using a photodiode "CONTROL".

After setting the required parameters of the radiation power and duration,

modulation and pressing the START button, a signal is generated resolution laser.

The radiation is switched off after a set duration. Turning off the machine

CHAIN, set the switch on the side of the unit in position

"0" 7. GETTING STARTED

7.1 Install the unit at a distance of no more than 1.0 m from the wall outlet.

7.2 Set the NETWORK switch to "0".

7.3 Connect the power cord to a wall outlet of 220 V.

7.4 Connect outrigger handle "BPB" or "VRIP" to the front connector

panel.

Attention! When you turn off the reclosing device is made

not less than 3 seconds.

8. OPERATION

8.1 When you turn on the power using the switch on the front panel NETWORK

the device in position "1" on the display shows: "Head №121003», the year ( "12" -2012g.) and

quarter ( "1") of release, "003" serial number; visible light wavelength spectrum

"405-700nm" with "BPB" remote turn on the handle or the length of infrared waves

DC "701-1050nm" light when the remote handle "VRIP"

(Start menu) (Appendix 4). When you press any button except the POWER button Δ

 or the display shows: TIME "00:00"; DOSE "00.00"; Part of the "00.0" (general

menu) (Appendix 4).

The initial menu is set after turning off the machine and its re

inclusion.

8.2 Setting the parameters "B" or "SP" radiation.

When the remote handle "BPB" set parameters "B" of the radiation.

When the remote handle "VRIP" set parameters "FE" radiation.

8.2.1 Installing the power of "B" emission (Annex 4):

Turn the handle outrigger "BPB"

a) briefly press the POWER button, and the displayed reading

POWER ▀% - 5 mW (typed) - 000 mW (controlled);

b) briefly press the POWER button Δ, while steps

increasing evidence of power "in the" laser, is shown on the display:

▀% -05mVt, ▀ ▀% -10mVt,

▀ ▀% -15mVt, ▀ ▀ ▀% -20mVt,

▀ ▀ ▀% -25mVt, ▀ ▀ ▀ ▀% -30mVt,

▀ ▀ ▀ ▀% -35mVt, ▀ ▀ ▀ ▀ ▀% -40mVt,

▀ ▀ ▀ ▀ ▀% -45mVt, ▀ ▀ ▀ ▀ ▀ ▀% -50mVt;

c) briefly press the POWER button , while steps

reduced laser power readings;

d) Press the START button and insert the end of the handle in the external photodiode jack

"CONTROL" and monitor the amount of power;

d) Press the STOP button.

8.2.2 Installing the power "FE" radiation:

Turn the handle outrigger "VRIP"

a) briefly press the POWER button, and the displayed reading

POWER ▀% - 10 mW (typed) - 000 mW (controlled);

b) briefly press the POWER button Δ, while steps

Increases Power "SP" laser readings displayed on the display:

b) briefly press the POWER button Δ, while steps

increasing the laser power readings, the display shows:

▀% -10mVt, ▀ ▀% -20mVt,

▀ ▀% -30mVt, ▀ ▀ ▀% -40mVt,

▀ ▀ ▀% -50mVt, ▀ ▀ ▀ ▀% -60mVt,

▀ ▀ ▀ ▀% -70mVt, ▀ ▀ ▀ ▀ ▀% -80mVt,

▀ ▀ ▀ ▀ ▀% -90mVt, ▀ ▀ ▀ ▀ ▀ ▀% -100mVt;

c) briefly press the POWER button , while steps

reduced laser power readings;

d) Press the START button and insert the end of the handle in the external photodiode jack

"CONTROL" and monitor the amount of power;

d) Press the STOP button.

8.2.3 Installing the modulation of the radiation:

If you press any button on the display shows: TIME "00:00"; DOSE

"0.00"; Part of the "0.0" (the general menu)

a) the indicator is displayed part of the "0.0";

b) a short press FREQUENCY Δ, thus increasing

reading tenths of Hz modulation;

c) briefly press the CLOCK button , thus decreasing readings

tenths of Hz;

d) Press and hold FREQUENCY Δ, with increasing evidence

units and tens Hz modulation;

d) Press and hold the CLOCK button , thus decreasing readings

units and tens Hz modulation.

8.2.4 Installation of the radiation duration:

a) the indicator is displayed TIME "00:00";

b) a short press TIME Δ, with increasing evidence

units and tens of seconds;

c) briefly press the TIME button , thus decreasing readings

units and tens of seconds;

d) Press and hold TIME Δ, with increasing evidence

units and tens of minutes;

d) Press and hold the TIME button , thus decreasing readings

units and tens of minutes;

e) Press the START button and carry out the procedure in accordance with the recruited

parameters.

8.3 The end of the procedure is carried out after a preset time or

pressing the STOP button.

8.4 Resetting the dose, frequency by pressing the STOP / RESET button

in the STOP state. Resetting TIME by pressing the STOP / RESET button

in the STOP state after pressing TIME TIME or delta Δ.

8.5 The display is controlled by the radiation dose D = x Rnabrannaya Tprotsedury

(J = W × s).

8.6 Set the NETWORK unit to the "0" position.


Attention! While working with the laser radiation is prohibited to work without

goggles! Avoid direct eye exposure radiation.

OBEREZHNO! KLAS 3R, apparently

TA invisible laser VIPROMІNENNYA,

KOLI VІDKRITE NOT Divit At beam

 Attention! Emergency Power Off is performed by

to "0" NETWORK switch on the side panel of the electronic unit.

Attention! When you turn off the reclosing device is made

not less than 3 seconds.

Attention! Storage box packaged produce in accordance with the

deposited handling marks.

 

The items will be shipped on second - third day after payment by registered priority airmail.

Delivery typically takes 10 to 14 days (about a week for Europe).

If you want to use other methods of shipment email to me.

ALL international buyers are Welcome!
 
The  shipping is flat for all world:

 

FREE SHIPPING  WORLDWIDE 

 

WE WILL COMBINE MULTIPLE WINS TO SAVE ON  SHIPPING
Guarantee of qualitative packing

30 days guarantee:

 We guarantee you complete satisfaction with all my products.

If you receive an item you did not order or if an item you ordered is received damaged or defective.
 We will refund you the price you paid for it or replace it with identical one.  We accept returns in U.S.A.
Item for returning must have the original tags and packing, otherwise it won't be accepted.

 

Thanks and good luck!