Krohn Copper and Nickel Plating Solutions & Anodes Set 2 Quarts & 2 Anodes
NICKEL SOLUTION AND ANODE
BRIGHT NICKEL ELECTROPLATING SOLUTION imparts a bright nickel electroplate when used in accordance with the fallowing instructions. The recommended plating bath temperature is 70 F to 75 F. Nickel plate articles using 2 volts or 10 to 20 amps per square foot. Articles to be plated must be cleaned before plating. Extra care is necessary to insure the removal of all polishing rouge, oil, grease, finger prints, etc. For best results, the pieces to be plated should be cleaned . This solution imparts a bright mirror-like finish and can be used as an underplate for rhodium, gold, and silver electroplating. Also includes one Nickel anode thatprovide the electical flow into the plating solution that draws the metal electroms from the solution to the piece you want to be plated. It is 24-gauge, 99.95%-pure nickel anode. Dimensions 1" x 6".This solution is non-hazardous to ship.

COPPER SOLUTION AND ANODE
KROHN ACID COPPER ELECTROPLATING SOLUTION is a non-cyanide electrolyte.
Articles to be plated must be cleaned before plating. Extra care is necessary to insure the removal of all polishing rouge, oil, grease, finger prints, etc. For best results, the pieces to be plated should be cleaned at 5-6 volts in a KROHN TIVACLEAN solution (8 Oz per Gallon of water heated to 160 - 180 F) Fallowed by a water rinse. Also includes Pure Copper anode that provide the electical flow into the plating solution that draws the metal electroms from the solution to the piece you want to be plated. Dimensions 1" x 6".
Copper plate articles in a room temperature bath using 3 to 9 volts & agitate bath if possible for best results.
Rinse the plated articles thoroughly in water and dry.
Use a PURE COPPER ANODE
*: All this products are made in USA


PRODUCT SPECIFICATIONS
.- Copper Solution
Size: 1 Qt / 0.946 lt
Copper plate articles in a room temperature bath using 3 to 9 volts & agitate bath
if possible for best results.
.- PURE COPPER ANODE .
Dimensions: 6" x 1"
Thickness: 24 ga

.- Nickel Solution
Size: 1 Qt / 0.946 lt
The recommended plating bath temperature is 70 F to 75 F. Nickel plate articles using 2 volts or 10 to 20 amps per square foot.
.- PURE NICKEL ANODE .
Dimensions: 6" x 1"
Thickness: 24 ga
Payment
Shipping
Returns
About Us

We accept PayPal. We do accept PayPal E-Checks.
We reserved the right to hold your order until payment cleared or confirmed.


​​​​​​​


 

We take great care packaging every item to ensure safe shipment to you. Once your order has been processed and we have received cleared payment, your item will be dispatched as soon as possible genarally (1-2 Business days). We ship trough USPS and UPS.


We do ship worldwide!.

Original sales receipt must accompany returns.

We accept returns for exchange or refund 30 calendar days after delivery of the product. At our sole discretion after 30 calendar days, we will offer an exchange or store credit only.


Items must be in "new, unaltered and unused condition". Definition of new, unaltered and unused condition is:

• -Without showing signs of wear or damage in any way
• -Within 30 calendar days of the delivery date (after 30 days no returns are allowed)
• -Must not be a special order or a custom order
• -Unless noted that it cannot be returned or has a different return policy time period other than that 30 days noted in that item's particular item description.


If an item is received damaged or is incorrectly shipped by us please contact us immediately sending a message. Items that are defective and shipped from us or items that you did not order but received from us will qualify for store credit or a cash refund.


Refunds are contingent upon inspection of item(s) once we receive it.


There is a 15% restocking fee for returned items that are not being exchanged and are not damaged. Again you MUST contact us within 30 days if you intend to return ANY item back to our store.


Items returned to us AFTER 30 days and WITHOUT contacting us will NOT be refunded.

Customer is responsible for all shipping costs if seller is not at fault.


Please contact us for more information on returning an item, please send a message and we will issue a Return authorization number (RA#). Thank you.

We are a family company prided ourselves on combining quality products with an exceptionally high level of service and principles. Our company is based in the sunny city of Doral, Florida, very close to Miami,Fl and their beautiful beaches.


In Waymil, LLC, We are proud to be an authorized dealer of many prestigious trademarks sfor the Jeweler's, Watchmakers, Gemologists, Manufacturers, Repairers, Students, beaders, Hobbyists and relatives industries.


Every item is carefully packaged using the latest technology to ensure safe shipment to you. Enjoy your visit!

NOTE: Visit WAYMIL E-bay Store to see Listings of other products, along with a variety of Hand Tools and much the best and large selection of metal working tools, beading supplies, and Jeweler's tools at excellent prices!!

Krohn Copper and Nickel Plating Solutions & Anodes Set 2 Quarts & 2 Anodes
NICKEL SOLUTION AND ANODE
BRIGHT NICKEL ELECTROPLATING SOLUTION imparts a bright nickel electroplate when used in accordance with the fallowing instructions. The recommended plating bath temperature is 70 F to 75 F. Nickel plate articles using 2 volts or 10 to 20 amps per square foot. Articles to be plated must be cleaned before plating. Extra care is necessary to insure the removal of all polishing rouge, oil, grease, finger prints, etc. For best results, the pieces to be plated should be cleaned . This solution imparts a bright mirror-like finish and can be used as an underplate for rhodium, gold, and silver electroplating. Also includes one Nickel anode thatprovide the electical flow into the plating solution that draws the metal electroms from the solution to the piece you want to be plated. It is 24-gauge, 99.95%-pure nickel anode. Dimensions 1" x 6".This solution is non-hazardous to ship.

COPPER SOLUTION AND ANODE
KROHN ACID COPPER ELECTROPLATING SOLUTION is a non-cyanide electrolyte.
Articles to be plated must be cleaned before plating. Extra care is necessary to insure the removal of all polishing rouge, oil, grease, finger prints, etc. For best results, the pieces to be plated should be cleaned at 5-6 volts in a KROHN TIVACLEAN solution (8 Oz per Gallon of water heated to 160 - 180 F) Fallowed by a water rinse. Also includes Pure Copper anode that provide the electical flow into the plating solution that draws the metal electroms from the solution to the piece you want to be plated. Dimensions 1" x 6".
Copper plate articles in a room temperature bath using 3 to 9 volts & agitate bath if possible for best results.
Rinse the plated articles thoroughly in water and dry.
Use a PURE COPPER ANODE
*: All this products are made in USA


PRODUCT SPECIFICATIONS
.- Copper Solution
Size: 1 Qt / 0.946 lt
Copper plate articles in a room temperature bath using 3 to 9 volts & agitate bath
if possible for best results.
.- PURE COPPER ANODE .
Dimensions: 6" x 1"
Thickness: 24 ga

.- Nickel Solution
Size: 1 Qt / 0.946 lt
The recommended plating bath temperature is 70 F to 75 F. Nickel plate articles using 2 volts or 10 to 20 amps per square foot.
.- PURE NICKEL ANODE .
Dimensions: 6" x 1"
Thickness: 24 ga

We accept PayPal. We do accept PayPal E-Checks.
We reserved the right to hold your order until payment cleared or confirmed.


​​​​​​​


 

We take great care packaging every item to ensure safe shipment to you. Once your order has been processed and we have received cleared payment, your item will be dispatched as soon as possible genarally (1-2 Business days). We ship trough USPS and UPS.


We do ship worldwide!.

Original sales receipt must accompany returns.

We accept returns for exchange or refund 30 calendar days after delivery of the product. At our sole discretion after 30 calendar days, we will offer an exchange or store credit only.


Items must be in "new, unaltered and unused condition". Definition of new, unaltered and unused condition is:

• -Without showing signs of wear or damage in any way
• -Within 30 calendar days of the delivery date (after 30 days no returns are allowed)
• -Must not be a special order or a custom order
• -Unless noted that it cannot be returned or has a different return policy time period other than that 30 days noted in that item's particular item description.


If an item is received damaged or is incorrectly shipped by us please contact us immediately sending a message. Items that are defective and shipped from us or items that you did not order but received from us will qualify for store credit or a cash refund.


Refunds are contingent upon inspection of item(s) once we receive it.


There is a 15% restocking fee for returned items that are not being exchanged and are not damaged. Again you MUST contact us within 30 days if you intend to return ANY item back to our store.


Items returned to us AFTER 30 days and WITHOUT contacting us will NOT be refunded.

Customer is responsible for all shipping costs if seller is not at fault.


Please contact us for more information on returning an item, please send a message and we will issue a Return authorization number (RA#). Thank you.

We are a family company prided ourselves on combining quality products with an exceptionally high level of service and principles. Our company is based in the sunny city of Doral, Florida, very close to Miami,Fl and their beautiful beaches.


In Waymil, LLC, We are proud to be an authorized dealer of many prestigious trademarks sfor the Jeweler's, Watchmakers, Gemologists, Manufacturers, Repairers, Students, beaders, Hobbyists and relatives industries.


Every item is carefully packaged using the latest technology to ensure safe shipment to you. Enjoy your visit!

NOTE: Visit WAYMIL E-bay Store to see Listings of other products, along with a variety of Hand Tools and much the best and large selection of metal working tools, beading supplies, and Jeweler's tools at excellent prices!!