2pcs REV-17 (РЭВ-17) USSR Coaxial Antenna Relay 75 Ohm NOS NIB
Up for sale lot of 2pcs REV-17 NEW Relay in original box.
The electromagnetic untight high-frequency coaxial relay of a direct current with one switching contact.
The relay is intended for switching of high-frequency signals with a frequency up to 1 GHz, during the work in coaxial paths.
FEATURES
Electric capacity between the opened contacts no more than 0.2 pf, attenuation at a frequency of 500 MHz not less than 30 dB.
The mass of the relay are no more than 140 g
TU RF4.562.009 specifications.
Technical parameters and operational characteristics
SUPPLY VOLTAGE:
Executions
|
Working
tension,
In
|
Operation current
at 298K (+25 °C), In,
no more
|
Resistance
windings at 298K (+25 °C), Ohm
|
RF4.562.009-00,-01
|
27+9-5
|
15.2
|
210+ 10-21
|
SWITCHING MODES:
Switching
ranges
|
Coordinated
loading, Ohm
|
Frequency
the switched MHz signal
|
Frequency
switching,
Hz, no more
|
Number
switching
cycles, no more
|
tension,
mkv
|
power, W
|
REV16
(-00)
|
REV17
(-01)
|
at norms.
distempers.
|
including
at
373K (+100 °C)
|
50
|
-
|
50
|
75
|
1000
|
5
|
105
|
5·104
|
-
|
30
|
50
|
75
|
500
|
1
|
105
|
5·104
|
-
|
50
|
50
|
75
|
500
|
1
|
105
|
5·104
|
RESISTANCE of CONTACTS: ≤0.5 Ohm
REACTION TIME: 30 ms max.
TINKLING SOUND TIME AT OPERATION: 3 ms max.
OTPUSKANIYA'S TIME: 30 ms max.
TINKLING SOUND TIME AT OTPUSKANIYA: 15 ms max.
KSVN 1.25 of max. (REV17), 1.43 max. (REV16).
ISOLATION RESISTANCE:
500 megohms - in norms. klimatich. conditions;
50 megohms - at the maximum temperature;
10 megohms - at the increased humidity.
ELECTRIC DURABILITY OF ISOLATION:
500 V ef. - at norms. klimatich. conditions;
220 V ef. - at the lowered atm. pressure;
300 V ef. - at the increased humidity.
VIBROSTABILITY: from 0.5 to 5 Hz with an amplitude up to 3 mm;
over 5 to 30 Hz with an amplitude up to 1.5 mm;
over 30 to 50 Hz with an amplitude up to 1 mm;
over 50 to 2000 Hz with acceleration to 75 m / с2 (7.5g);
over 50 to 2000 Hz with acceleration to 100 m / с2 (10g).
AMBIENT TEMPERATURE: from 213K (-60 °C), to 373K (+100 °C).
RELATIVE HUMIDITY: to 98% at 308K (+35 °C)
ATMOSPHERIC PRESSURE: from 666 Pas (5 mm of mercury.) to 203000 Pas (1520 mm of mercury.).