10 HP 3-Phase 230V 60 gal. Stationary Electric Rotary Screw Air Compressor with Refrigerated Dryer
 
Technical details
Air Dryer Included: Yes
With Tank: 60 Gal. ASME Tank
Hp-Air Compressor: 10 HP
Phase - Electrical: 3
Input Voltage: 230V 60Hz,
Free Air CFM @ Max. Pressure: 39-35
(F)NPT Outlet: NPT 3/4"
Max. Pressure: 100-125 psi
Full Load Amps: 24A
dBA @ 3 Feet: 80
Motor RPM: 3600
Duty: Continuous
 
Overall Length: 42"
Overall Depth: 28"
Overall Height: 35"
Packing Weight: 600 lbs
Application:
 
It can widely used for production, pharmaceutical, textile, auto repair, aviation, metallurgical and other industrial fields.
Air Brushing,Blow Cleaning,Bolting/Wrenching,Brad Nailing/Stapling,Cutting,Drilling,Finish Nailing,Framing Nailing,
Grinding,HVLP Painting,Hobby Nailing,Hobby Painting,Inflation,Roof Nailing,Sanding,Spraying,Surface Prep
 
.....................................................................................
 
60 Gallon Vertical Air Tank ASME Coded
 
Max Pressure : 200 PSI / 1.4 MPA
Tank Material:Carbon Steel
Connection NPT:1/4”NPT
Air Tank Size:60 Gallon Vertical Air Tank
Dimensions:33*28*53 inch
 
 .....................................................................................
 
Refrigerated Air Dryer
Air Capacity: 35CFM
Working Operating pressure: 0.7-1.0MPa
Cooling: By Air
Inlet temperature:<45℃
Ambient temperature: < 40℃
Pressure dew point: 3-10℃
Power supply:110V/60Hz
Refrigerant type: R134a
Power consumption: 0.585 KW
Refrigerant amount: 0.4 kg
Manufaoturer date: 190227
Serial number: 18026
 
Dimension:27.5*23.6*15.7 inch
Weight: 114 lbs
 
Regular maintenance interval schedule
Every 50 hours or weekly
--- Check oil level.
--- Check intake filter, if necessary clean it.
--- Drain condensation water from oil tank.
Every 500 hours
--- Check and adjust belt tension if necessary (belt driven only)
Every 2000 hours
--- Replace lubricants (for mineral lubricants oil)
--- Replace oil filter.
--- Replace intake filter
Every 4000 hours
--- Replace lubricants (for synthetic lubricants oil)
--- Replace oil separator
--- Clean cooler for dirt
 
Attention: Attention: 
1、 Replace filter element and lubricant after first 500 hours of operation.
2、 Use incorrect lubricant oil and spare parts will cause compressor damage, only use original manufacture oil and parts.
3、 The service life of compressor depends on the environment conditions such as dust, vent etc.
 
 
 

 

DataCaciques

 


On May 24, 2023 at 03:39:06 PDT, seller added the following information:
DataCaciques


On Dec 18, 2023 at 18:32:02 PST, seller added the following information:

DataCaciques