V5 anti-roll 3D Touch Probe edge finder CNC probe compatible with mach3 and grbl
V5 metal version 4MM handle (including needle +2 meter noodle) (tungsten steel handle)
The DIYO three-coordinate probe can realize the functions of fast positioning, edge finding, center finding, shape measurement and so on by connecting the CNC to the knife edge, which greatly solves the trouble of positioning the workpiece during the second clamping during the machining process.
Working voltage: 5-24V wide voltage
Indicator light: green light when power on, red light after trigger
The shell is made of fine frosted black oxidized aluminum alloy, flat anti-roll design, and the stylus handle is machined in stainless steel. It is suitable for grbl control board and Mach3 and other control boards/boxes.
An installed stylus is included with the probe
(Ordinary tungsten steel ball stylus)
Fine-tune the concentricity to within 0.05 before shipment, and measure and adjust it after you get it.
Notice:
Be sure to use AAA or above ER11 collet chuck, otherwise the concentricity of the probe cannot be guaranteed.
(Even if the ordinary collet chuck is installed with our probe to adjust the concentricity, remove the probe and install it again, the concentricity will be deviated)
 
Calculation method of probe yaw
Deflection refers to the difference in projection between the center point of the stylus and the actual trigger center point in the measurement direction. (Generally speaking, if you find the center of the circle, you don’t need to calculate the deflection value. If it is used for edge finding, you need to The measured value plus or minus the stylus deflection value.)
1. Place a gauge or rectangular workpiece on the table
2. Use the probe to measure the value of each surface in × direction 3. Deflection value = (×2-x1-workpiece length-ball head diameter)/2
1.
Need to turn on the spindle speed?
Never, never, never.
Don't laugh, there are such users.
 
2.
How to distinguish the three wires?
The red wire is VCC, the black wire is GND, and the white wire is IO.
 
3.
Why is the concentricity different every time the probe is installed?
Because your ER chuck spring clip cannot guarantee 100% uprightness. Every time the probe is installed, even if the concentricity is adjusted to 1 wire, there will still be deviations when the probe is removed and installed again. So your chuck is best to buy AAA and above accuracy (concentricity <=0.005), because many chucks in China have false standards, it is recommended to use a high-precision gauge or tungsten steel rod to check the table after installing the chuck. Look at concentricity. It’s best to place the dial indicator at a distance of 50mm from the chuck, which is roughly the distance between the ball head of our probe and the root of the handle.
 
4.
Why am I obviously an AAA chuck, and the concentricity is still poor?
That's because you bought a virtual label chuck.
Under normal circumstances, if the spindle jumps by 0.01, the AAA chuck clamps the milling cutter and the table tool holder, the error may not exceed 0.02, and the error may not exceed 0.03 at most. There will be a slight angular deviation between the center axis of the collet chuck and the center axis of the spindle, which will be magnified by the length of your tool holder. Usually you use a calibration meter to measure the root of a milling cutter, and you can't see a big error, but because the stylus of the probe is about 50mm away from the tool holder, the error will be further magnified. So, be sure to choose genuine high-precision chucks
Packing:1PCS
Warranty period: 120 days


On Nov-15-21 at 19:36:07 PST, seller added the following information:

DataCaciques