DC24V 2 Channels Wireless RF Remote Control Switch Relay Alarm FOB Key Remote
 
 
 
QTY: 1pcs 2 Channel receiver contrller and 1 pcs 2button handsender . (This remote doesnot have a battery inside )
 
 
 
 
Receiver :

 

Technical indicators:

 
Working voltage: DC24V;
Operating frequency: 433.92MHz;
Receiver sensitivity:-95dB;
Encoding: Receiver Recording;
Momentary / Latch / Toggle selectable (defult is Momentary , Latch Mode need 2 buttons handsender );
Output mode : Relay switch or DC24V power switch  (Relay switch is defult ) ;
Receiver size: 62 * 35 * 22 mm;
Max load : 500W;  
2 Channel;
 
Advantage :
1:  Receiver Mother board have a learning key , if the remote is lost , must buy EV1527 or PT2262 remotes to re-learn;

Output:

 

Work mode (programmable )
singnal Inter-locking (Latch)
singnal Self-locking (Toggle)
singnal Non-locking (Momentary is defult )
 

 

 

Momentary------------Press the Transmitter button A, the receiver relay A is ON, release button A; the receiver relay A is OFF, the same as B/C/D ,Every channel is Independent ;

 

Toggle---------------Press transmitter button A for 1 time , the receiver relay A is ON, press button A again, the receiver relay A is OFF, the same as B/C/D. Every channel is Independent ;

 

Latched------------------

Press transmitter button A, the receiver relay A is ON, the relay B/C/D is OFF.

Press transmitter button B, the receiver relay B is ON, the relay A/C/D is OFF.

Press transmitter button C, the receiver relay C is ON, the relay A/B/D is OFF

Press transmitter button D, the receiver relay D is ON, the relay A/B/C is OFF.

 
User guide instruction : 
1:Clear the deposit information
      Keep pressing learnig key on receiver controller board , LED turn on after 2 seconds , then turn off after 4 seconds , it means clearing successfully .  ( our remote is already programmed before dispatch , please don't clearing ).

 

 

 
2:  Relay working mode selecting :
1: keep pressing learning key on the receiver controller , 
LED turn on after 2 second , then turn off after 4 second, then the receiver controller enter programming state , but not release the finger , still keep pressing the learning button ,
LED blink once after 2 second , release the finger on learing key , it is Momentary mode ,
or still keep pressing learing key , 
LED blink twice after 2 second , release the finger on learing key , it is Toggle mode ,
or still keep pressing learing key ,   
LED blink 3 times after 2 second , release the finger on learing key , it is Latch mode ,
 
 
3: Learning the remote to the receiver controller:

  A: Keep pressing learnig key on receiver controller board , LED turn on after 2 seconds , release the finger on learning key , press " A" buttons on the remote  work state LED blink 3 times , it means "A" buttons was memoried by Channel 1 .

      B: repeat step A to memoried "B" button by Channel 2 .
 
 
 Relay mode :
Normally close (NC ) ;
Normally open (NO ) ;
  • Normally-open (NO) contacts connect the circuit when the relay is activated; the circuit is disconnected when the relay is inactive. It is also called a Form A contact or "make" contact. NO contacts may also be distinguished as "early-make" or NOEM, which means that the contacts close before the button or switch is fully engaged.
  • Normally-closed (NC) contacts disconnect the circuit when the relay is activated; the circuit is connected when the relay is inactive. It is also called a Form B contact or "break" contact. NC contacts may also be distinguished as "late-break" or NCLB, which means that the contacts stay closed until the button or switch is fully disengaged.
Connection to 2 channel light :
 
 
Control DC24V motor forward backward rotation: 
 
in the backside of receiver controller , Connect B and C to DC24V circuit , then COM1 and COM2 will output positive DC24V .

 

 
 
Transmitter :

 

 

Features / Specifications :

1. 2 buttons;
2. High stability, SMT chip, frequency stabilization SAW, ultra-high-frequency transistor;
3: Large power;

 

Technical Data :
Transmitter Module No.: TB423;
Power supply : 12V 23A battery (not included ) , please buy battery from here : https://www.ebay.com/sch/i.html?_from=R40&_trksid=p2047675.m570.l1313.TR3.TRC2.A0.H0.X12V+23A+battery.TRS0&_nkw=12V+23A+battery&_sacat=0 .
 
Operating current: 28-33mA;
Oscillation mode: SAW resonator;
Modulation mode:ASK/OOK;
Operating frequency:433.92MHZ ;
Encoding format: EV1527 encode IC ;
Transmit power : 200mW ;