Product Description

Temperature and Humidity Control Module Digital Dual Output Automatic High Precision Constant Temperature Humidity Control Board


Specifications:

Product model: XY-DTH1

Temperature measurement range: -20°C~60°C

Humidity range: 00%~100%RH

Control accuracy0.1C 0.1%RH

Detection probeintegrated sensorOutput type: relay output

Output capaity: maximum 10A

Product weight144g


Product functions are mainly classified into two categories: temperature function and humidity function;

The temperature function is as follows:

1.  Automatic recognition of working mode:

The system automatically recognizes the working mode according to the start temperature/stop temperature;

Starting temperature>stop temperature, cooling mode ‘C’;  starting temperature;

2.  Cooling mode:

When the detection temperature ≥ the starting temperature, the relay is turned on, the red indicator light is on, and the refrigeration equipment starts to work;

When the detected temperature is less than or equal to the stop temperature, the relay is closed, the red indicator light is off, and the refrigeration equipment stops working;

3.  Heating mode:

When the detection temperature is less than the start temperature, the relay is turned on, the red indicator light is on, and the heating device starts to work;

When the detected temperature is greater than or equal to the stop temperature, the relay is closed, the red indicator light is off, and the heating device stops working;

4.  Temperature correction function OFE (-10.0 ~ 10.0℃):

The system works for a long time, and there may be deviations.  Through this function, the actual temperature=measured temperature+calibration value;


How to set the start/stop temperature:

1.  In the running interface, press and hold the ‘TM+’ key for more than 3 seconds to enter the startup temperature setting interface.  The test can be used to modify the parameters through the TM+ TM- keys.  After the parameter modification is completed, wait 6 seconds to automatically exit and save;

2.  In the running interface, press and hold the ‘TM-’ key for more than 3 seconds to enter the stop temperature setting interface.  The test can be used to modify the parameters through the TM + TM- keys.  After the parameters are modified, wait for 6 seconds to automatically exit and save;


Humidity functions are as follows:

1.  Automatic recognition of working mode:

The system automatically recognizes the working mode according to the start humidity/stop temperature;

Start humidity> stop humidity, dehumidification mode ‘d’;  start humidity 

2.  Dehumidification mode:

When detecting humidity ≥ start humidity, the relay is turned on, the green indicator light is on, and the dehumidification equipment starts to work;

When the detected humidity is less than or equal to the stop humidity, the relay is closed, the green indicator light is off, and the dehumidification equipment stops working;

3.  Humidification mode:

When the detected humidity is less than the start humidity, the relay is turned on, the green indicator light is on, and the humidifying device starts to work;

When detecting humidity ≥ stop humidity, the relay is turned off, the green indicator light is off, and the humidifying device stops working

4.  Humidity correction function RH (-10.0 ~ 10.0℃):

The system works for a long time, and there may be deviations.  Through this function, the actual humidity = measured humidity + calibration value;


How to set start/stop humidity:

1.  In the running interface, press and hold the ‘RH+’ key for more than 3 seconds to enter the start humidity setting interface.  The test can be used to modify the parameters through the RH+ RH- key.  After the parameters are modified, wait for 6 seconds to automatically exit and save;

2.  In the running interface, press and hold the ‘RH-’ key for more than 3 seconds to enter the stop humidity setting interface.  The test can be used to modify the parameters through the RH+ RH- key.  After the parameters are modified, wait for 6 seconds to automatically exit and save;

Operation interface description:

Working mode display.  After the start temperature/humidity, stop temperature/humidity and other parameters are set, the current mode ("H/C", "E/d") will be displayed in front of the temperature/humidity;

When any relay is turned on, the upper left corner of the interface displays "OUT".  If the temperature relay is turned on, the temperature operating mode "H/C" flashes to indicate a reminder;  if the humidity relay is turned on, the humidity operating mode "E" flashes /d", as a reminder;


Other functions:

1.  Remote reading/setting of parameters:

You can set parameters such as start temperature/humidity, stop temperature/humidity, and temperature/humidity correction through UART;

2.  Real-time reporting of temperature/humidity:

If the temperature/humidity report function is turned on, the product will detect the temperature/humidity and relay status at 1s intervals and transmit it to the terminal via UART, which is convenient for data collection;

3. Relay enable (open by default):

If the relay enable is turned off, the relay remains off;


How to modify the temperature/humidity correction value:

1. In the running interface, double-click the ‘TM+’ key to enter the correction value setting interface; the lower line displays the correction value type, and the upper line displays the specific value; (OFE: temperature correction value RH: humidity correction value)

2. At this time, short press the ‘TM-’ key to switch the parameter to be modified, and use the RH+ RH- key to modify the specific value; long-press and short-press are supported;

3. After the parameter modification is completed, double-click the ‘TM+’ key to exit the correction value setting interface and save the data;


How to turn on/off the relay enable switch:

In the running interface, short press the'TM-' key to turn on or off the temperature relay enable (on: turn on OFF: turn off). After returning to the running interface, if the temperature relay is off, the temperature symbol'℃' will flash, Reminder.

In the running interface, short press the'RH-' key to turn on or off the humidity relay enable (on: open OFF: close). After returning to the running interface, if the humidity relay is in the off state, the humidity symbol'%' will flash, Reminder.


Note: 

1.Due to the light and screen difference, the item's color may be slightly different from the pictures.

2.Please allow 1-3cm differences due to manual measurement.


Package Included:

1x Temperature and Humidity Control Module



About Us
Welcome to our store!
 
We are a professional worldwide wholesale company, with our own factory located in China.
 
We supply many products including video game, health & beauty, phone accessories, computers accessories, camera & camcorder,car accessories, Clothing accessories, games, toys & hobbies, jewelry, antique & craftwork. High product quality,reasonable prices, excellent customer service and a reliable credit standing is our tenet.
Payment
We accept PayPal only.
 
Payment must be received in 7 business days of auction closing.
 
Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
 
Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
Shipping
  • Will ship within 10 business days of receiving cleared payment.
  • The shipping time details, please read the shipping and delivery together with the price.
  • We ship to your PayPal address. Please make sure your PayPal address is correct before you pay.
  • Considering the cost of business and easy shipping, usually the item is packed in retail packaging.

CountryShipping Time

Working Days + Saturday 
+ Sunday

5-78-1516-2021-2526-30>31
United StatesRate(item arrived)5.1%50.1%29.6%10.5%4.7%Refund
United KingdomRate(item arrived)9.9%63.2%19.1%3.4%4.4%Refund
AustraliaRate(item arrived)21.4%50.0%14.3%7.2%7.1%Refund
FranceRate(item arrived)10.5%28.6%43.8%10.1%7.0%Refund
GermanyRate(item arrived)11.1%22.2%30.3%20.9%15.5%Refund
CanadaRate(item arrived)0.0%47.1%31.4%17.6%3.9%Refund
SpainRate(item arrived)3.7%24.1%48.2%13.8%10.2%Refund
Terms
If this item is defective upon receipt, customer has up to 14 days from date of receipt for exchange of a new one.But buyers should be pay for the shipping charge for returning.
 
We care about our valued customers, and are always willing to work things out. If you have any problems, please e-mail us immediately.
Contact Us
If you have any questions, please feel free to send eBay message to us, our service specialists 24 Hours a Day, 7 Days a Week (maybe there is some delay in weekends).
 
Our aim is to provide Top Level Customer Service, normally so we will try our best to solve any problem.
 
Please DON'T leave negative or neutral feedback if you haven't received item in 30 days, because we have mentioned the shipping time repeatedly.