PZEM-028  Parameter
1.Voltage

Measurement range: 40~400V

Display format:<100V display such as:80.0V

≥100V display such as:220V

Accuracy: ±1%

  1. Current

Measurement range: 0~100A

Display format: <10A display such as:1.00A

<100A display such as:10.0A

≥100A display such as:100A

Starting measurement:0.02A

Accuracy: ±1%

  1. Power

Measurement range: 0~22kW

Display format:<10W display such as:5.0W

<100W display such as:50.0W

<1000W display such as:500W

<10000W display such as:5.00kW

≥100V display such as:22.0kW

Starting measurement:2.2W

Accuracy: ±1%

  1. Power factor

Measurement range: 0~1

Display format: such as:1.00PF

 

Note: error adjustment must be carried out under pure resistance (PF=1.00) load environment, otherwise the active power error after adjustment will be too large!
 

PZEM-026 Parameter
Display instruction

1.Voltage

Measurement range: 40~400V

Display format:<100V display such as:80.0V

≥100V display such as:220V

Accuracy: ±1%

2.Ampere

Measurement range: 0~100A

Display format: <10A display such as:1.00A

<100A display such as:10.0A

≥100A display such as:100A

Starting measurement:0.02A

Accuracy: ±1%

 

Other Function

  1. Backlight control

The backlight can be turned on or off by short press the key

2. Error adjustment

The product is calibrated 100% before delivery, the user can adjust error manually. the method is as follows

Step 1: long press the key (about 3 seconds) until the screen digit flashes, then release the key;

Step 2: Digital flicker means entering error adjustment state, and the digit cycle flickers in sequence: voltage high digit→voltage middle digit→voltage low digit→voltage decimal point→ampere high digit→ampere middle digit→ampere low digit→ampere decimal point. The flicker represents the present adjustable digit, short press the key to adjust the value (Digital 0-9 cycle, decimal point shift);

Step 3: long press the key (about 3 seconds) after the adjustment, the screen display PASS and return to the normal display interface, means the adjustment is successful.


 