Feature:

1. Track and Manage Your Health: Helps you track and manage your health. All in one machine for blood pressure and blood glucose measurement. Easy to read with a large digital display, you can get fast results. Perfect for seniors and those with poor eyesight.
2. Blood Glucose Meter: Blood glucose measurement with compatible test strips for quantitative detection of glucose concentration in capillary whole blood (excluding newborns).
3. Convenient Memory Mode: Stores 352 sets of test results with date and time. You only need to press the memory key (M key) to enter memory mode and view blood pressure and blood sugar test records. If you want to leave memory mode, you can directly press the power button or wait for 3 minutes, the machine will shut down.
4. Chronological Display and Auto Replacement: Easy access to memory mode to review blood pressure and blood glucose test records. Memory function displays results in chronological order, with the most recent records appearing first. Automatic replacement of oldest records when memory exceeds 352 sets. Clear all memory values by holding down the memory button for 3 seconds while the device is powered off.
5. Accurate: Each blood pressure cuff wrist ensures accurate measurements professionally. ABS materials provide strength and durability of the blood pressure monitor.


Specification:

Item Type: Blood Pressure Monitor
Material: ABS, Nylon
Weight: Approx. 314g / 11.1oz
Battery (Not Included): 2 AAA Alkaline Batteries
Model: TD 3213A
Product Size: Approx. 90x73mm / 3.5x2.9in (Excluding Cuff)
Memory Capacity: Stores 198 Measurements With Date And Time
Power Saving Mode: Automatically Turns Off After 3 Minutes Of Inactivity
Blood Glucose Sample Size: 0.5μL
Operating Environment: 10-40 Degrees Celsius, Relative Humidity Below 85%
Machine Storage Environment: -20 to 60 Degrees Celsius, Relative Humidity Below 95%
Blood Glucose Measurement Range: 1.1-33.3 mmol/L or 20-600 mg/dL
Accuracy of Blood Glucose Measurement: Coefficient of Variation (CV) <5%
Accuracy of Blood Glucose Measurement:
For Blood Glucose Values <4.2 mmol/L (75 mg/dL), Error within ±0.83 mmol/L (15 mg/dL);
For Blood Glucose Values≧4.2 mmol/L (75 mg/dL), Error within ±20%
High Blood Pressure Warning: Flashing Corresponding Values When Systolic Pressure ≥140mmHg or Diastolic Pressure ≥90mmHg to Indicate High Blood Pressure
Blood Pressure Measurement Range: 0 to 300 mmHg
Accuracy of Blood Pressure Measurement: ±3 mmHg or ±2% of the Reading
Heart Rate Measurement Range: 40-199 Beats Per Minute
Accuracy of Heart Rate Measurement: ±4% of the Reading
Key Functions:
1. Memory Key: Use To Access Memory Mode
2. Power Key: Use To Start Blood Pressure Measurement, And Power On Off The Device
3. Setting Key: Use To Enter The Setting Mode, Set Time, Date, And Language On/Off
4. Screen: Displays Measurement Results Or Error Messages
5. Strip Insertion: Slot For Inserting The Test Strip
Screen Display Explanation:
1. Temperature Unit
2. Measurement Result Display Area
3. Pulse Display Area
4. Unit Of Pulse Measurement
5. Irregular Heartbeat Indicator
6. Low Battery Indicator
7. Date and Time Display Area
8. Blood Drop Symbol
9. Test Strip Symbol
10. On Off Symbol For Voice Function
11. Systolic Pressure High Pressure
12. Unit Of Blood Pressure Measurement
13. Unit Of Blood Glucose Measurement
14. Blood Glucose Level
15. Diastolic Pressure Low Pressure
16. Memory Mode Indicator
Machine Settings: The Device Allows Settings For Date (Year, Month, Day), Time (Hour, Minute), And Voice Function (If Available). The Setting And Memory Keys Are Used For Setting. The Steps And Screen Sequence For Setting Are As Follows:
1. Press And Hold The Setting Key For At Least Three Seconds To Enter The Setting Mode.
2. The Last Two Digits Of The Current Year Will Appear And Flash.
3. Adjust The Number Using The Memory Key And Press The Setting Key To Move To The Next Step.
4. The Flashing Month Date Will Appear. Adjust The Number Using The Memory Key And Press The Setting Key To Move To The Next Step.
5. The Flashing Hour Minute Will Appear. Adjust The Number Using The Memory Key And Press The Setting Key To Move To The Next Step.
6. The Volume Setting Will Appear. Use The Memory Key To Select The On Off For The Voice Function, And Press The Setting Key To Turn Off The Device Automatically.
Blood Pressure Measurement:
1. Relax And Sit Quietly For At Least 15 Minutes Before Measurement. Wrap The Wrist Cuff Around Your Wrist.
2. Adjust The Distance Between The Upper Of The Device And The Palm To Approximately 0.6 To 1.3 Cm (About The Width Of One Finger).
3. Tighten The Wrist Cuff And Fasten It Securely, Ensuring It Is Not Too Tight.
4. After Wearing The Wrist Cuff, Place Your Wrist In Front Of Your Chest, Making Sure It Is At The Same Level As Your Heart. Keep Your Wrist Straight And Your Arm Relaxed. Then Press The Power Button To Start The Measurement.
5. All LCD Screen Indicators Will Light Up, And The Device Will Perform A Self Check. After The Check Is Complete, The Device Will Automatically Apply Pressure.
6. When The Appropriate Pressure Point Is Reached, The Wrist Cuff Will Slowly Deflate To Perform The Measurement. During The Measurement, The Device Will Flash A Heart Symbol.
7. After The Measurement Is Complete, The Device Will Display The Systolic Pressure (High Pressure), Diastolic Pressure (Low Pressure), And Pulse Rate. If The Systolic Pressure Is ≥140mmhg Or The Diastolic Pressure Is ≥90mmhg, The Corresponding Numbers Will Blink To Indicate High Blood Pressure.


Package List:

1 Bottle x Test Strip (25PCS)
1 x Blood Pressure Blood Glucose Meter with Cuff
1 x User Manual
1 x Storage Bag


Note:

1. Shipments without lancing device and lancets. During the blood drawing process, you can use a household embroidery needle that has been slightly wiped with alcohol to draw blood or test blood sugar directly.
2. If there is no input action within 2 minutes after inserting the test strip or 60 seconds without inserting the test strip, the blood glucose meter will automatically turn off.
3. Repeated measurements may cause congestion in the wrist and affect the accuracy of the measurement. Improvement methods: you can raise your left hand and make a fist several times, or remove the wristband and rest for at least 2‑3 minutes before measuring. This device is not suitable for use with newborns.
  

1. Our listing price includes the value of goods,packaging cost,and export taxes,not including international duties.
2. duties,taxes,and charges are not included in the item price or shipping fee.
3. The duties are buyers' responsibility.Please check with your country's customs office determine what these additional costs will be prior to your purchase.
4. All disputes arising from the duties will be submitted to ebay for solution.

1. Any questions, pls. contact us via ebay message or email us.We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.

2. If you are satisfied with our service, pls. kindly leave us a positive feedback and give us the Detailed Seller Rating with all "5 " in very area
3. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better. We strive to keep all our customers satisfy. 

https://image-us.chengykj.com/upload/third_resource/image/feedback.jpg


We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders. 

https://image-us.chengykj.com/upload/third_resource/image/shipc73.jpg

DataCaciques