CONTEC Patient Monitor co2 Capnograph Vital Signs Monitor 6 parameter ETCO2 IBP TS15

               
1.Introduction 

The monitor is applicable for clinical monitoring in operating room, postoperative observation room, ICU/CCU ward, emergency room, etc. of adult, pediatric and neonate. The patient's vital parameters (ECG (including ST-segment measurement and arrhythmia analysis), RESP, SpO2, PR, NIBP, TEMP, IBP and CO2, etc.) can be monitored. Monitored information can be displayed, reviewed, printed and stored..

Function

1)15.6" high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance.

2)Independent physiological and technical alarm function, convenient for medical staff to quickly know patient’s condition.

3)Luminous “ON / OFF” button design, convenient to operate at night.

4)Modular design: the modules can be configured and combined flexibly and conveniently, expanded and upgraded at any time, meets the monitoring requirements of different departments on different parameters.

5)Support dynamic hot-plugging parameter module: no need to restart the device, plug-and-play, change the monitoring parameters at any time as clinical requirements.

6)Adopt high-performance processor, stable, reliable and fast to process information.

7)Patient information can be rapidly entered, patient type (adult / neonate / pediatric) can be quickly switched, meets the requirements of different departments.

8)Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.).

9)With the functions of waveform freezing, holographic waveform storage and review.

10)Automatic data storage in case of power failure; optional built-in memory card, achieves large-capacity data storage.

11)With HDMI expansion interface, the display screen can be connected according to clinical requirements.

12)Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring.

13)Fanless design, ensures no noise and low power consumption during working.

14)3-channel built-in recorder used to print real-time waveform is optional.

15)Connect to Central Monitoring System developed by our company by WiFi / Wired, convenient to transmit patient’s real-time data.

16)Standby mode, be applied to ICU, avoids affecting patient’s rest, one-button switching, reduces the workload of medical staff.

Performance

(1)ECG

Lead type:

3-lead: I, II, III 

5-lead: I, II, III, aVR, aVL, aVF, V

12-lead: I, II, III, aVR, aVL, aVF, V1,V2,V3,V4,V5,V6

Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV

Scan speed: 12.5 mm/s, 25 mm/s, 50 mm/s

HR

Measurement and alarm range:

Adult: 15 ~ 300 bpm

Pediatric/neonate: 15 ~ 350 bpm

Resolution: 1 bpm

Accuracy: ± 1 % or ± 1 bpm, whichever is greater

ST-segment detection

Measurement and alarm range: - 2.0 mV ~ + 2.0 mV

Accuracy: - 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater

Other range: unspecified

Arrhythmia analysis: 23 kinds

Pacemaker: yes

(2)RESP 

Measurement mode: R-F (RA-LL) impedance

Respiration rate:

Measurement range: 

Adult: 0 rpm ~ 120 rpm 

Pediatric/neonate: 0 rpm ~ 150 rpm

Resolution: 1 rpm

Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater; 

 0 ~ 6 rpm, unspecified

Apnea alarm: 10 ~ 120 s, not alarm

Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s

(3)NIBP

Measurement mode: Oscillometry

Working mode: Manual/AUTO/Continuous 

Measurement interval in AUTO mode: 1 min, 2 min, 2.5 min, 3 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 1.5 h, 2 h, 3 h, 4 h, 8 h

Measurement period in Continuous mode: 5 minutes

Measurement and alarm range: 10 ~ 270 mmHg

Resolution: 1 mmHg

Cuff pressure accuracy: ± 3 mmHg

Measurement accuracy:

Maximal mean deviation: ± 5 mmHg

Maximal standard deviation: 8 mmHg

Over-pressure protection:

Adult mode: 297 ± 3 mmHg

Pediatric mode: 240 ± 3 mmHg

Neonatal mode: 147 ± 3 mmHg

(4)CONTEC SpO2

Measurement range: 0 % ~ 100 %

Resolution: 1 %

Accuracy: 70 % ~ 100 %, ± 2 %;

 0 % ~ 69 %, unspecified

PR

Measurement and alarm range: 25 ~ 250 bpm

Accuracy: ± 2 bpm or ± 2 %, whichever is greater

(5)Nellcor SpO2

Measurement range: 1 % ~ 100 %

Measurement accuracy: 70 % ~ 100 %: ± 2 % (adult / pediatric)

 70 % ~ 100 %: ± 3 % (neonate)

 0 % ~ 69 %: unspecified

Nellcor PR 

Measurement range: 20 ~ 300 bpm;

Measurement accuracy: 20 ~ 250 bpm, ±3 bpm; 

 251 ~ 300 bpm: unspecified;

Upper limit of alarm: upper limit - 2 ~ 300 bpm;

Lower limit of alarm: 20 bpm ~ lower limit + 2 bpm

(6)Masimo SpO2

Measurement range: 1 % ~ 100 %

Measurement accuracy: 

70 % ~ 100 %: ± 2 % (adult / pediatric, under conditions of no motion), ± 3 % (under conditions of motion)

70 % ~ 100 %: ± 3 % (neonate, under conditions of no motion)

1 % ~ 69 %: unspecified

Masimo PR

Measurement range: 25 ~ 240 bpm

Measurement accuracy: ± 3 bpm (under conditions of no motion), ± 5 bpm (under conditions of motion)

Upper limit of alarm: upper limit - 2 ~ 240 bpm

Lower limit of alarm: 25bpm ~ lower limit + 2 bpm

(7)TEMP

Channel: dual-channel 

Measurement range: 0 ~ 50 ℃

Resolution: 0.1 ℃

Accuracy: ± 0.1 ℃

(8)CO2

Measurement mode: mainstream or sidestream 

CO2 measurement range: 0 ~ 150 mmHg

CO2 resolution: 0.1 mmHg: 0 ~ 69 mmHg

 0.25 mmHg: 70 ~ 150 mmHg

Accuracy: 

0 ~ 40 mmHg: ± 2 mmHg

41 ~ 70 mmHg: ± 5 %

71 ~ 100 mmHg: ± 8 %

101 ~ 150 mmHg: ± 10 %

AwRR measurement range:

Sidestream: 2 ~ 120 rpm

Mainstream: 2 ~ 150 rpm

AwRR accuracy: ± 1 rpm

Apnea alarm: yes

(9)IBP

Channel: 4-channel

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measurement and alarm range: -50 ~ 300 mmHg

Resolution: 1 mmHg

Accuracy: ± 2 % or 1 mmHg, whichever is greater

(10)Power supply: 100 ~ 240 V ~  50/60 Hz

(11)Safety class: class I, defibrillation-proof type CF applied part

(12)Waterproof degree: IPX2



Shipment

1. We will ship the item within 48 hours after receiving your payment,  please kindly leave your detail shipping address and telephone number, both are very important for the shipment,thank you.

2.We will upload the tracking number after shipment,you can search from both ebay and paypal.You can track online.
3. If you haven't received the item after 2 weeks of your payment, please contact me immediately! 


Terms of Sale

1.If you have a defective item, you want to return or discount. Please  contact us within 14 days from you receive the shipment.All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.
2.we will refund the money to you when we get the return items. Or replace  item for you. We will deal with the refund in 2 business days when we  get the info from you.Please read our trade Policy before buy , if you don't agree our trade policy please don't buy it.

International Buyer--Please note:

Import duties,Taxes are not included in the item price.These charges are buyers' responsibility


We are the manufacturer of medical equipment for 17 years, the following are our main products:

ECG /  ECG holter   EEG / EEG Holter      B-ultrasound

Patient Monitor      Fetal doppler             Fetal Monitor 

Spo2 Monitor          Stethoscope              Medical Image....

Agent in the world!

We are look for partners in the world now!

Do you want  to become our agent in you conutry?

Join US!

Skype:xuebox3

contec.med.mary # hotmail dot com

               
           
       
       
   

Only English User Manual,Please contact us if you need other language version.thank youibay365