●WORKS WITH ALEXA: Use voice or app control to control your air conditioner from anywhere.Worls with wifi ,
you can use app on your smart phone control your air conditioner from anywhere

●Ultra efficient cooling and heating 12,000 BTU/h capacity with 19 SEER Certified AHRI Certified & ETL Certified
 (Includes about 16 FT Line Set)

●Ultra capable performance: Heating during -13°F weather and cooling during 122°F weather Pre-Charged R-410A

●DESIGNED FOR HOME & BUSINESS: Powerful performance and dependable durability with high quality design for 
an attractive appearance Ultra silent operation: as quiet as 34 dB on the indoor section and 52 dB on the outdoor unit

●WHAT’S INCLUDED: Includes indoor air handler, outdoor condensers and installation kit with 16ft. line set and
 communication wire. Important note: requires professional installation.

-- Accessories that fit (Extra price)

Brackets (Click Here)

Line set cover  (Click Here)

16FT line set (Click Here)

25FT line set (Click Here)

50FT line set (Click Here)


SPEC

Model

AES19-12H1B

Power supply

115V~/60Hz/1P

Rated Cooling
(95F/35C)

Rated cooling capacity

Btu/h

12000

EER

Btu/W.h

10.5

SEER

Btu/W.h

19.0

Rated Heating
(47F/8.3C)

Rated Heating capacity

Btu/h

12000

HSPF Rating (Region IV)

Btu/W.h

10.0

COP

W/W

3.0

COP (5/-15)

W/W

1.95

Input Consumption

Cooling

W

1140

Heating

W

1170

Rated Current

Cooling

A

10.1

Heating

A

10.4

MXimum Operation Pressure

PSIG

650

MXimum Fuse Size

A

30

Moisture removal

Liters/h

1.6

Indoor noise level at cooling

Turbo/High/Med./Low/Mute

40/37/34

Outdoor noise level

dB(A)

52

Connecting Pipe

Gas

inches

3/8''

Liquid

inches

1/4''

Connecting Wiring

Size x Core number

4×16AWG

Net dimensions  (W x D x H)

Indoor

inch

31.92x11.49x8.07

Outdoor

inch

28.66x12.01x21.65

Net weight

Indoor

Ibs

19.8

Outdoor

Ibs

65

Loading Capacity (IN+OUT)

40’HC (without pipe)

250

Loading Capacity (IN+OUT)

40’HC (with pipe)

234

Loading Capacity (IN)

40’HC/ 40'GP/ 20'GP

718/638/302

Loading Capacity (OUT)

40’HC/ 40'GP/ 20'GP(without pipe)

360/270/126

Loading Capacity (OUT)

40’HC/ 40'GP/ 20'GP(with pipe)

348/258/120

*** Indoor Unit ***

Indoor air circulation/Hi

m3/h

650

CFM

380

*** Outdoor Unit ***

Outdoor air circulation/Hi

m3/h

2290

CFM

1350

Factory Refrigerant charge(7.5m pipe)

g/oz

1002g / 35.34ozs

Factory Precharge Line

(m/ft)

7.5 / 25

MXimum Line Length

(m/ft)

15 / 50

MXimum Height Difference Between Indoor and Outdoor

(m/ft)

10 / 33

Additional refrigerant charge

(g/m, oz/ft)

20 / 0.22

Ambinet  temperature

Indoor(cooling/ heating)

F

62.6~89.6/32~86

Outdoor(cooling/heating)

F

5~122/-13~86