Hot Sale


Feature:

1. Suitable for scooter M165 complete set system replacement, 1:1 high imitation scooter.
2. Adopts high performance 32‑bit MCU, overvoltage, overcurrent, overheat, undervoltage and other abnormal condition functions.
3. Constant cruising, braking energy recovery, adjustable limit.
4. Suitable for M365 electric scooter.
5. Double close system, quiet operation, second acceleration smoothly cutting easy to install, service life, durable.


Specification:

Condition: Brand New
Item Type: Controller Kit
Material: Metal + Rubber
Color: As Pictures Shown
Product Composition: Controller + Meter + Throttle + Front Light + Tail Light + Connecting Wire
Power Parameter:
Vehicle Upper Limit 27KM/H
Climbing Angle <=15°
Drive Motor Maximum Torques: 35NM x 2
Drive Motor Maximum Power: 350W x 2
Instant Maximum Power 700W
Motor Control Method: Sinusoidal Vector Control, Current + Close Control Algorithm
Controller Parameter:
Voltage:DC36V
Power:350W
Low Voltage:30V
Rated Current:16A
Weight: Approx. 367g


Functional Description:
1. Starting up
2. Shutdown
Press 3s close, at the same, buzzer rings twice
3. Light
Under starting up state, press short once(less than 1 second), turn on front and rear light, headlight all along light, while tail light flashing.
4. Brake
Electronic brakes + disc brakes, tail light on brake
5. Gear
Startup state, default is low file; Press the button twice (twice in one second) to switch gears
Green low gear; Red high grade
6. Battery display
33v-36v firstly light very
36v-37v one or two light bright
37v-38.5v one or two light bright
38.5v or, one, two, three, four light
Low voltage alarm:When battery voltage under 33V, firstly light flash,buzzer rings 6
7. Low voltage alarm mode
8. Constant cruising
Steady for about 6 seconds to automatically start cruising control; After cruising fixed, you can release the throttle; Depress the brake or push the accelerator again to release the constant control and enter manual mode
9.
Low gear 15±2km/h; the high gear 25±2km/h
10. Automatic shutdown
Automatic shutdown 10 minutes after no operation



Error codes and solutions:
1)“ E1” motor fault
Solution:Change the position of the yellow and green lines of the motor
2)“ E2” regulation handle trouble
Solution:Turn the control handle a few times, then check for wire connections
3)“ E3” Locked-rotor fault
Solution:Check wiring
4)“ E4” MOS tube failure
5)“ E5” undervoltage
Solution:Check or replace the battery
6)“ E6” Controller/instrument communication failed
Solution:Check wiring connection
7)“ E7” Overvoltage
Solution:Check or replace the battery.
8)“ E8” Phase-line current/mean current sampling no fault
Solution:Check wiring connection
9)“ E9” Braking trouble
Solution:Check wiring connection


Package List:

1 x Controller
1 x Board
1 x Front Light
1 x Tail Light
1 x Accelerator
1 x Connecting Wire
2 x Displayer Accessory
2 x Displayer Film


New Arrival