Electronic Load Resistor USB Interface Discharge Battery Test 25W Tester UK

Instructions for USB Intelligent electronic load

-Model: LD25

NOTE:

This product has no reverse connection protection, the input polarity cannot be reversed, otherwise the product is permanently damaged and cannot be repaired  

Technical Parameters:

Rated operational voltage:DC4-25.0V

Max discharging power:25W

Rated operational current: 0.25-4.00A (when fan don’t work, the minimum constant current is 0.05A )

Fan Speed: Large size intelligent temperature control fan, speed 5800±10%RPM

Constant current resolution:±(1%+3 digits)

Heat dispatch method.:intelligent temperature

control fan + All aluminum fan

Working temperature:-10℃-40℃

Adjustable potentiometer :Precision multiloop adjustable potentiometer

Display mode :4 bit LED tube

Expansion port:Micro USB port、Type-C port

Product weight:56.51g

Product size:83.8x41.1x27.9mm

Information : 

1, LD25 user manual download page :http://www.mediafire.com/folder/q2o63jc8df6qc/LD25

2, Youtube video 

​3, Customer Feedback 

LD25--_01LD25--_02LD25--_03LD25--_04LD25--_05LD25--_06LD25--_07

Product Structure

QQ20180524171616

A. Micro USB port:MAX current 2A

B.USB male port (widened power wire,MAX current 4A)

C. Type-C port:MAX current 4A

D. All aluminum fan

E. Intelligent temperature control fan

F. 4 Bit LED tube

G. Precision multiloop adjustable potentiometer

H. “SET” button:press “SET” to switch display status, Press and hold the button to set the load output recovery mode after protection removed. 

I. “ON/OFF” button: press the button to open or close output. Press and hold the button to set the boot default status of open or close

Function Introduction:

SADFASFAFG

a. Protection function:

OVP (over-voltage protection): there is OVP at 25-30V; it will be damaged permanently over 30V.at OVP, LED show OVP, as picture 1 show)

OTP(over-temperature protection): load temperature is over  80℃, the LED show OTP, as picture 2 show.

OPP(over-power protection): the power is over  80℃, the LED show OPP, as picture 3 show.

b. Set output recovery mode after load entering protection status, manual or automatic

c. View the voltage value, current value and power value of the load. 

d. Intelligent temperature control fan. When the current is over 2A or the temperature is over 40℃, the fan will start.

e. Precision multiloop adjustable potentiometer: you can adjust the current precisely, upto 0.01A. so you don’t need to adjust a big current mistakenly to damage the power supply. So the power supply will not be damaged due to mistakenly adjustment

f. you can set default boot status freely, open or close.

Operation Instruction

The load is powered at the range of 4-25.0V (the input polarity cannot be reversed, otherwise the product is permanently damaged and cannot be repaired), the LED will be flashing to remind current setting value, waiting for output. Press ON/OFF button, open output to start work.

1. Adjust output current value.

  Turning the rotary control clockwise increases the value and anticlockwise decreases the value. According to the needs of the situation, the potentiometer can realize coarse adjustment or fine adjustment. The fine adjustment can be accurate to 0.01A.

2, Adjust LED display status

Press “SET” to adjust the LED display status, default display output current value. Press “SET” button to display *.**A、**.*P、**.*V followed by recycling.

3. Open or close load output

  Press “ON/OFF” button, you can open or close load output

4, Set load default boot status (open or close status, Factory default close status)

HGFDGD  

Press and hold “ON/OFF” button to set load default boot status freely. Press and hold “ON/OFF” button, if the LED will display “--ON”, as picture 4, the load will open output when power on next time; If the LED display”-OFF”, as picture 5 show, the LED will display current value flashing at last shutdown when power on next time, then press “ON/OFF” button to open output.

5, Set the load output recovery mode after protection removed.

Press and hold “SET” button, to set output recovery mode after protection removed. Press and hold “SET” button, if the LED will display “--ON”, as picture 4, and the protection was removed, the load will recover to work; If the LED display”-OFF”, as picture 5 show, and the protection was removed, the LED still show protection status, then press “ON/OFF ‘button, the display will display present setting current flashing, then press “ON/OFF‘ button again, the load recover to work. 

NOTE:  Please check the output current of power bank carefully. The current of the general power bank is generally small, so adjust smaller current when the load was used.

Application

Assist to measure Micro USB cable good or not

Assist to measure Type-C cable good or not

Assist to measure output current capacity of charger good or not

The usage of large batch ageing test at the charger factory

1. PayPal payment accepted only.

2. Items will be shipped to your eBay address. Please make sure it is correct.

3. Payment must be received 4 days after auction ended.

1. Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.

2. If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 14 days of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer. 

3. Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.

4. We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication with us. Please allow max 2 business days for us to response. 

When you satisfied with our product and services please leave us positive feedback.

If a problem occurs, contact us immediately with any email request. Just contact us using the " Ask the seller a question" link on eBay. 


On 12-Jun-18 at 05:04:29 BST, seller added the following information:

DataCaciques


On 12-Jun-20 at 04:46:48 BST, seller added the following information: