Instructions
Principle of
the CMS50F Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection
Technology is adopted in accordance with Capacity Pulse Scanning & Recording
Technology,the Pulse Oximeter can be used in measuring the pulse oxygen
saturation and pulse rate through finger.The product is suitable for being used
in family, hospital, oxygen bar, community healthcare, physical care in sports
(It can be used before or after doing sports, and it is not recommended to use
the device during the process of having sport) and etc.
Major Features
- Small in
volume、light in weight and convenient in carrying
- Operation of the
product is simple, low power consumption
- SpO2
value display
- Pulse rate value
display, bar graph display
- Pulse waveform
display
- The display mode
can be changed
- Screen
brightness can be changed
- A pulse rate
sound indication
- With measured
data overruns limits and low-voltage alarm function, the upper/down alarm range
can be adjustable
- With clock
function
- Battery capacity
indication
- Low-voltage
indication: low-voltage indicator appears before working abnormally which is due
to low-voltage, and with alarm function
- With
SpO2 value and pulse rate value of storage, the storage data can be
uploaded to computers
- Real-time data
can be transmitted to computers(Only for the Lei Mo probe)
- Connected with
an external oximeter probe
Main performance
- Display Mode:
1.3" 65K Color OLED display
- Screen
Resolution: 128*96
- SpO2 Measuring
Range: 0%~100%(the resolution is 1%)
- Accuracy:
70%~100%: ±2%, Below 70% unspecified.
- PR Measuring
Range: 30bpm~250bpm(the resolution is 1bpm)
- Accuracy: ±2bpm
or ±2% (select larger)
- Measurement
Performance in Weak Filling Condition:SpO2 and pulse rate can be
shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%,
pulse rate error is ±2 bpm or ±2% (select larger).
- Resistance to
surrounding light: The deviation between the value measured in the condition of
man-made light or indoor natural light and that of darkroom is less than
±1%.
- Power
Consumption: less than 100mA
- Voltage: DC
3.6V~4.2V
- Power Supply:
Voltage 3.7 rechargeable lithium battery × 1
- Battery working
hour: The theoretical number is 20 hours
- Battery working
life: Charge and discharge no less than 500 times.
- Safety
Type:Interior Battery, BF Type
Accessories
- Sell in
standard
A user manual
A USB line
PC software
An adult-oximeter probe
A power adapter
Physical Identity
Dimension: 61(L) × 56(W) ×
24 (H) mm
Weight: About 60g (with
the lithium battery*1)
Certification
CE, FDA