Automatic controller. 30A high power (up to 4500W)
- Measuring range: -50 ... + 150 ° C
- Mounting: Wall
We are pleased to introduce Polish production unit for controlling the temperature in heating or cooling systems.
Application:
- electric smokehouses
- drying fruits and mushrooms
- and:
- incubators, terrariums, aquariums, stills
- boilers, heaters, etc.
- pump and hot water
- Cooling:
- refrigerators, freezers, refrigerated counters
- fans, coolers
- electric heaters, stoves
- heating cables, icing systems
The controller has a digital temperature readout and display calibration function. It uses a method to adjust the ON / OFF (ON-OFF) with adjustable hysteresis.
The mobile device - with power cables.
Thanks to the wiring device after use can take, hide, or simply use for the next job.
- length of the power cable 1.4 m
- the length of the cable socket of 0.5 m (thus the cable socket could hang and not be in pool)
The load unit is equipped with a cable 3 x 2.5 mm thick load 16A of protection IP44
If you wish to connect the device to the receiver with higher power consumption, replace the wiring.
Electrical appliance caution.
Features:
- Measuring range - 50.0 ... + 150.0 ° C
- 2 relay outputs (control, alarm)
- 30A relay
- hermetic
- Measurement and setting with an accuracy of 0.1 ° C
- Two additional ALARMS MIN and MAX temperature
- Memory temperature MAX, MIN and time of departure
- Temperature sensor made of stainless steel complete
- ECO function
- Color display <30% larger
- Weekly timer (optional)
- Memory settings and settings after power failure
- NTC temperature sensor included
Power: Standard is a 230V ~ +/- 15%
Technical data:
Entrance:
- NTC temperature sensor 5kOhm at 25 ° C
- digital input, alarm
- Measuring range: -50 ... + 150 ° C
- Accuracy: +/- 0.5 ° C
- Sampling period: 330 ms
- Display resolution: 0.1 ° C over the range of
- Setting resolution: 0.1 ° C over the range of
- Display: LED 4 digits with a height of 14mm with graphical icons
- Method of control: ON-OFF with hysteresis
- Accuracy of adjustment: adjusted in the range 0.1 ... 20.0 ° C
- Exit
- regulatory
- 30A relay, durability of 100 thousand. cycles
- for resistive load 4500W
- inductive load: 1500W
alarm:
- 8A relay, durability 100k. cycles
- for resistive load 1800W
- inductive load: 400W
Additional functions:
- temperature alarm MIN and MAX
- sound signaling the temperature alarm and sensor failure
- ECO function
User manual in Polish, on request English, German.