Highly Trusted British Brand. Worldwide Famous for its Quality and Reliability. 

Lucas VRLA AGM Batteries quality manufactured batteries are capable of delivering up to 30% more deep cycling, making them a reliable source of power for more trips, longer journeys and longer life. Every battery is completely maintenance free, totally sealed – no spillage and safe to transport.

Features:

  • VRLA AGM Technology
  • Extra deep cycling capability for longer life 
  • Totally sealed - No Spillage
  • Completely Maintenence Free
  • Vibration resistant
  • Non-hazardous
  • Higher peak capacity
  • Increased initial capacity
  • Improved energy density
  • Enhanced recharge ability
  • Fortified plate construction
  • Improved cycle life
  • Safe and Easy to Transport

Lucas LSLA20-12 VRLA AGM Battery  (Valve Regulated Lead Acid Absorb Glass Mat)

Battery: Lucas LSLA20-12

Voltage: 12V       

Capacity: 20AH (Replace 12V 17AH, 12V 18AH, 12V 19AH, 12V 21AH, 12V 20AH, 12V 22AH)

Dimensions : Length 180mm   x  Width 76mm  x   Height 167mm

Fully Sealed Lead Acid Battery - Totally Sealed for Life and Safe with ONE YEAR Warranty

Note:  GEL/AGM means 'Absorbed Glass Mat' - The plates are wrapped and Gel electrolyte is absorbed by the mat. This gives you a battery that is more resilient to cold weather and input voltages from your charger than full Gel, giving you a very robust Cyclic battery.


Fully Sealed (cannot spill)
 - Rechargeable - Deep Cycle battery. Fitted to various types of Mobility Vehicles, Golf Trolleys, Battery Operated Ride-On Toys, Electric Bikes, Electric Scooters, UPS (Un-interupted Power Supply) Systems, Telecommunication Systems, Back-Up Systems, Jump Starts, Emergency Lights etc.

Note: Our stock has GREY, Black and GREEN cases, we supply either, depending on Stock at the time - It is exactly the same battery

 Suitable for cyclic and standby power applications. For standby power this range has a nominal 5 - 8 year life.

NOTE: THIS TYPE OF BATTERY IN STANDARD AGM OR GEL SHOULD BE KEPT ON CHARGE WHEN NOT IN USE (OR AT LEAST FULLY CHARGED AFTER USE) TO GET MAXIMUM LIFE.

  • It also has many other uses, including anywhere a low voltage, low power, back-up supply is required 
  • For Standby applications it has a LOW standby discharge of approx 3% per month
  • Battery can be used in any position
  • Excellent recovery from deep discharge


VRLA AGM Deep Cycle Battery Care & Maintenance:

     VRLA AGM Deep Cycle batteries are manufactured to the very highest of standards, but to get the very best performance and longevity out of your batteries it is well worth following a simple care and maintenance program:

  •          Always recharge your battery as soon as you can after use after discharge and keep it as fully charged as possible during long periods of in-activity.
  •          Please must use Continual Automatic chargers with these batteries such as NUMAX 12V 4A DC Fully Automatic Intelligent Connect & Forget Battery charger can be left attached to the battery for long periods and will look after your battery at correct state of charge until you need it next.
  •          Avoid completely discharging your battery (Below 10.5V) as this will reduce its cyclic lifespan.
  •          When the battery is not in use always store it in a cool, dry and well ventilated place.
  •          From time to time make sure the terminals are free from dust and dirt, and all connections are sound.
  •          Please must not use Trickle charge with these batteries.
  •          An equalizing charge for a 12volt battery required that it be charged with a voltage of at least 14.4 volts for a period of at least one hour once a month, or every 10 discharge cycles. An equalizing charge prevents battery stratification and reduces sulfation, the leading cause of battery failure. Equalizing should be performed when a battery is first purchased (called a freshening charge). Reduced performance can also be an indicator that an equalizing charge is needed.
  •          All batteries, regardless of their chemistry, will self-discharge. The rate of self-discharge for lead acid batteries depends on the storage or operating temperature. At a temperature of 80 degrees F. A lead acid battery will self-discharge at a rate of approximately 4% a week. A battery with a 125-amp hour rating would self-discharge at a rate of approximately five amps per week. Keeping this in mind if a 125 AH battery is stored for four months (16 weeks) winter without being charged, it will lose 80 amps of its 125-amp capacity. It will also have severe sulfation, which causes additional loss of capacity. Keep your batteries charged while not in use.

If you Doubt or want information about the product before buying you can ask questions through eBay Message

We Dispatch by COURIER usually next day but may take two days on occasion

We have no weekend deliveries

You can collect if you prefer

  Our Courier Company always tries to deliver the parcel twice only after that you have contact them to arrange the collection within three days of second attempt and collect your parcel from their nearest depot  to your home otherwise they will send the parcel back to us. We don’t do WEEKENDS DELIVERIES.

Please note the advice given from Starter Batteries customer services regarding suitable products should be treated as a guide only. It is the customer’s responsibility to check physical size, Post layout and rating against their old battery or battery tray before ordering. All goods should be inspected upon delivery before signing to ensure that the item has not been damaged during transit. If goods prove to be damaged, do not sign. Refuse delivery and contact us within 1 working day.

All the products sold by GCD GARAGE LTD (SC 390120) (including Batteries, Battery Chargers, Springs, Pneumatic and Hydraulic Fittings etc.) should be fitted by a qualified person having knowledge about these products; therefore under no circumstances shall GCD GARAGE LTD (SC 390120) be liable for any consequential injury, loss or damage due to misuse or fitting of the products supplied to the buyer.

Note: No warranty for the deep discharged or flat battery or under 10.5V. All Batteries warranted against premature failure due to manufacturing or material defects only. The warranty does not cover Sulphation, Wear and Tear; Deep discharged more than 80%, Overcharging, Physical Damage, Incorrect application.

Warning:-Remove bungs (plugs) immediately after receiving the battery or batteries (All types of flooded lead acid batteries) even in storage condition. Bungs (Plugs) are only for transportation use. If these instructions are not followed(removing bungs immediately) battery may get bulged or explode. Therefore, The Glasgow Car Detailing Garage Ltd is not liable for any damage, loss and injury due to not following the instruction and the warranty is voided.

Don't USE or BUY our products for life saving machine and equipments or where life is on RISK. If you have any question or doubt we are happy to help you please contact us.

EMERGENCY FIRST AID

INHALATION - Remove from exposure, rest and keep warm. Obtain medical attention immediately

EYE CONTACT - Wash out with plenty of water for at least 15 minutes. Obtain Urgent medical attention 

SKIN CONTACT - Remove contaminated clothing immediately and wash affected skin with plenty of water. Obtain medical attention

INGESTION - If the electrolyte has been confined to the mouth give large quantities of water as mouth wash ensuring that it is NOT swallowed. If electrolyte has been swallowed, give water to drink immediately. DO NOT INDUCE VOMITING. OBTAIN URGENT MEDICAL ATTENTION

BURNS - Apply sterile bandage. Obtain medical attention

ALWAYS WEAR PROTECTIVE CLOTHING WHILE WORKING AND HANDLING BATTERIES