Eltek Smartpack RS-232 front Controller Monitoring and Control Unit (242100.111)



 
The Smartpack controller is a monitoring and control unit used as the vital nerve center of the DC power plant. You operate the system from the elegant front panel, using three front keys and the LCD-display. They represent the main interface between you and the system.
 

Specifications

Input Voltage 24/48/60 VDC nominal system voltages
Dimensions (WxHxD) 109 x 44 (1U) x 140 mm / 4.3 x 1.7 x 5.5” 
 
Applications
CAN bus communication Smartpack utilizes a digital interface architecture (CAN bus communication). It allows the unit to support dedicated communication channel with each rectifier, providing for increased number of functions and greater flexibility.
 
Modular design
The Smartpack is extremely flexible in its expandability. Additional units connected to the CAN bus can be added to provide extended functionality and increased number of measuring points. Accordingly, system components can be set up and upgraded to meet the demand of any tailor-made power solution.
 
Product Description
The Smartpack controller is a powerful and cost-effective module, developed for monitoring and controlling a wide range of Eltek Valere’s DC power supply systems, such as Powerpack, Flatpack2 and Minipack DC power systems. You can also operate the system locally via a PC using the PowerSuite PC application, or remotely via modem, Ethernet and the Web. The module then utilizes the USB- or RS-232 ports to interface with a local PC, SNMP or Web adapters.

Key Features:

  • Front panel LCD and buttons for on-site service without PC. (Not on Basic Slave model)
  • USB- or RS-232 interface for PC connection locally or remote monitoring and control via modem, Ethernet, web or SNMP.
  • 6/2 user programmable relay outputs for traditional remote monitoring
  • 6/2 user programmable inputs for monitoring of other equipment on site
  • Battery monitoring and testing without site attendance
  • Temperature compensated charging for increased battery lifetime
  • Battery lifetime indication
  • Password protected operator access levels
  • Alarm/event log with time and date
  • Windows-based PC communication software

Remote Monitoring and Control

  • From a PC running PowerSuite a Windows-based communication program installed on a remote computer, the system can be monitored and controlled via modem or Ethernet network
  • From a PC running a WEB Browser the system can be monitored and controlled via Ethernet network
  • From an NMS via Ethernet (SNMP) With an SNMP agent connected to the Smartpack, the system can be monitored and controlled from a Network Management System (NMS) through Ethernet on Simple Network Management Protocol (SNMP)
  • Using alarm relays (voltage free contacts) 6/2 internal failsafe alarm relays provide voltage free contacts that can be connected to equipment used for traditional alarm monitoring

Features

System

  • Output Voltage Measurement
  • Total Load Current Measurement
  • Load/Battery Disconnect
  • Alarm Level Settings (major / minor)
  • Alarm Log (up to 1000 events, 10k on HW v2)
  • Real Time Clock with Battery Backup o Site Text/ID
  • Test of Relay Outputs
  • Voltage Level setup
  • Data logging (up to 7000 data points)

Battery

  • Battery Current Measurement
  • Battery Temperature Measurement (optional)
  • Battery Testing (acc. to discharge table or set time limit)
  • Battery Test Information (10 latest tests)
  • Setup of Battery Data
  • Battery shunt setup
  • Battery quality indication
  • Battery Boost Charging
  • Battery Cable Voltage Drop Compensation
  • Temperature Compensated Charging
  • Protection against Temperature Probe Failure

Rectifier

  • Available information about each rectifier, e.g. serial
  • number, version, internal temperature
  • Individual Rectifier Current Measurement
  • Individual Rectifier Input Voltage
  • Efficiency Management

Local Monitoring and Control

  • From a PC running PowerSuite a Windows-based communication software, can also communicate with the Smartpack through an USB serial or RS-232 cable
  • LCD and three keypads for local operations If any alarm (major or minor) is activated, a (red or yellow) LED is lit in the front panel, the alarm text appears in the LCD and the corresponding alarm relay is activated In normal operation, the front LCD will display the output voltage, battery current, load current and charge mode. (Not on Basic Slave version)

 

Available Alarms

All alarms can be set up with monitoring of minor, major, average and peak levels.

System

  • Mains Failure (individual phases)
  • Digital Inputs (programmable names)
  • Load Disconnect (voltage or timer)
  • Load Fuse
  • Load Current

Battery

  • High Battery voltage
  • Low Battery voltage
  • High Battery temperature
  • Low Battery temperature
  • Battery Capacity
  • Battery Disconnect
  • Battery Fuse
  • Symmetry Failure
  • Battery quality indication
  • Battery discharge current

Rectifier

  • Rectifier Failure
  • Critical Rectifier Failure (> 1, programmable)
  • Rectifier Capacity w. programmable level
  • Rectifier Current Limit
  • Rectifier Overvoltage Protection
  • Rectifier Current
Eltek Smartpack RS-232 front Controller Monitoring and Control Unit (242100.111)



Payment & Shipping

The payment method we can accept: Paypal

Delivery is carried out all over the world. Most countries can use UPS expedited shipping.
The goods are dispatched within 2 working days.

We will not be responsible for any loss because of wrong or undeliverable shipping address.

If you didn't receive the item until the estimated delivery date, please feel free to contact us.

Contact Us

If the current Quantity cannot meet your requirement, please contact us for more stock.

Please contact us if you are not satisfied with the item after receive it. Just contact us using the "Ask the seller a question" link on eBay.

All replies will be sent to your email, if you don't get response within 1-2 business days, pls check your My messages' in case your email provider has an overly-aggressive spam filterblocking eBay's emails. Please email us AGAIN.

Feedback

Please contact us before leaving a neutral or negative feedback. We would try our best to help you solve the problem. Please allow us to reply your email within 24 hours.

We will provide the service as best as we can, cause the feedback and ★ ★ ★ ★ ★ is what we are striving for. Please email me through "My Messages" or "Contact seller" if you have any question about our listings or your purchasing.