220V 15KW swimming pool heater SPA constant temperature hot tub electric water heater

The ST series pool heaters are special used for small pool less than 5CBM, massage pool and hot spring to heat and keep warm; Meanwhile, can be a assistant for heat pump in heating. This product adopts latest constant temperature controller, temperature sensor replaces traditional magnetic flow switch, it improves greatly of trouble free in working time, adaptability of water environment and stability.

 

Important:

1. Read through the manual carefully to know better about the heater’s installation and operation, and check the parameters before installation.
2. Check the circulation system first before turn on the heater.
3. Never disassemble the heater when connecting to power supply.
4. Never turn on the heater without water
5. No power switch is designed for the heater. The front panel switch can only turn off the controller, thus you should cut off the main power supply before performing maintenance or repair.
6. Proper grounding is important.
7. Start the circulation pump for at least 2 minutes before turn on the heater, and turn off the circulation pump at least 2 minutes after turn off the heater.
8. Once unexpected high temperature 60℃(140℉)occurs, the temperature switch cuts off the system. You need to cut off the main power supply, resolve the fault and wait the temperature to fall below normal temperature, then press the ‘Reset’ button to restart the heater.

 

 

Control system automatically heat-up procedure

 

1. Preparation stage

Once reconnected to power or if the water temperature is 1℃ below the user setting temperature at least 10 minutes after entering the waiting stage, the heater enters the preparation stage.‘PUMP WORKING’indicator lights. If hint message ‘’ does not appear on the panel within 2 minutes, and the water temperature is 1℃ below the user setting temperature after 2 minutes, the heater enters next stage pre-heat stage.

 

2. Pre-heat stage
In this stage, heater heats up for 10 seconds and waits for 90 seconds. ‘Heating’ indicator lights for 10 seconds. If hint message ‘’ does not appear on the panel and the water temperature is 1℃ below the user setting temperature, heater enters next stage heat-up stage.

3. Heat-up stage
In this stage, all heating elements turn on, and heating indicator turns on as well. If hint message ‘’ does not appear, heater will heat up to 1℃ above the user setting temperature, then heating indicator blinks for 2 minutes. After that, circulation pump turns off for models with circulation pump control. Heater enters next stage waiting stage.

4. Waiting stage
Waiting stage lasts for at least 10 minutes. 10 minutes later, if the water temperature is 1℃ below the user setting temperature, the heater jumps to preparation stage, otherwise, it remains in the waiting stage.
The automatically heat-up process is non-stopping and will continue to circulating through all stages until the control system or heater is power off. You could ask for models with separated circulation pump control function.

 

 

Control panel functions

▲ Increase the user setting temperature by 1℃ or 2℉.
▼ Decrease the user setting temperature by 1℃ or 2℉.


 

Switching button

1. Switch between temperature unit:Press # button for more than 3 seconds,panel displays ℃ and ℉ in turns. Release the button once the unit you wish to choose appears, 5 seconds later, panel restore to display the current water temperature.
2. Switch between temperature sensors:Press# button, the panel will blink and display temperature measured by temperature sensor 2. After 5 seconds or press the#button again, panel will restore to display current water temperature which is measured by temperature sensor 1.


 

Temperature display and setting

1. Temperature display range 6℃~53℃ or 43℉~127℉。
2. Temperature setting range 22℃~50℃ or 72℉~122℉,factory default temperature is 42℃。
3. Set the temperature
Press▲ or ▼ button to increase or decrease the setting temperature by 1℃(2℉),and the panel blinks and display the setting temperature. 5 seconds later, the panel stops blinking, confirm the setting change and restore the current temperature display.
4. If reconnected to power, the user setting temperature is set to default temperature 42℃.

 

 

Unique control system

1. The flow-temperature sensor is always under the control of software, accurately monitoring the temperature status of the whole system, and then adjust the settings to maintain the water temperature and protect the heater from unexpected situations.
2. No mechanical sensors, avoid any mechanical failure to affect the function of the heater.
3. Avoid affection of ion accumulation to mechanical sensors.
4. Greatly reduce unnecessary circulation cycles, prolong the life of circulation pumps and save more energy.



Intelligent self-diagnose function

The control system keeps on monitoring the running status of every parts of the heater, and quickly reacts and displays corresponding hint message for any incident, so as to avoid any damage or malfunction happens.

If any fault happens, the heater is stopped immediately, and corresponding hint message will display on the panel for user or technician to decide where the fault is. The safety of customer is the top priority.

 
Feature
 
 
    • Manual reset temperature control switch: Once unexpected high temperature 60℃ occurs, the temperature switch cuts off the system
    • Unique control system: ST series are the newest generation with our unique control system
    • Sensor technique are: A. The flow-temperature sensor is always under the control of software, accurately monitoring the temperature status of the whole system, and then adjust the settings to maintain the water temperature and protect the heater from unexpected situations; B. No mechanical sensors, avoid any mechanical failure to affect the function of the heater; C. Avoid affection of ion accumulation to mechanical sensors; D. Greatly reduce unnecessary circulation cycles, prolong the life of circulation pumps and save more energy
    • Intelligent self-diagnose function: The control system keeps on monitoring the running status of every parts of the heater, and quickly reacts and displays corresponding hint message for any incident, so as to avoid any damage or malfunction happens
 
Specifications
 
 
    • Condition: New
    • Housing material: Aluminum-coated plate
    • Power: 15 KW
    • Current: 50A
    • Volt: AC 220
    • Wire: 3*10 mm²
    • Net Weight: 7.5 kg/16.5lbs
    • Package Size: 120*560*380 mm/4.7*22*14.9"
 
Package Content
 
 
    • 1 x Pool Heater(Does not include power plug)
    • 2 x Interface
We accept PayPal only.
  • Payment must be received within 7 business days of auction closing.
  •      
  • We ship to PayPal's address only. Please make sure your address in EBAY can match with your shipping address on PayPal.
  •      
  • All major credit cards are accepted through secure payment processor PayPal.
  •      
  • TOTAL AMOUNT DUE includes the final auction price plus S&H (Shipping and Handling).
  •      
  • S&H will be determined based upon the ship to address.
  •      
  • PLEASE NOTE: S&H DOES NOT INCLUDE DUTIES, LOCATL TAXES OR ANY OTHER IMPORTATION FEES.

1. Item processing time. We will ship the products within 1-5 working days upon the confirmation of your cleared payment, when buyers have some special request (e.g.Voltage, color...etc.), we may delay to ship the orders and will inform buyers about it. Do please check your message box in 1-2 days after payment is cleared. Otherwise order may be cancelled due to insufficient of your information.
 

2.Shipping methods. Items are shipped out via SpeedPAK or E-packet or any other shipping method that can fit your country, we will choose the reasonable way for you.
 
3. Delivery time may vary with countries and international shipping for some countries may be much slower than expected. Also your local custom may delay the shipping a lot due to the custom duty they want to charged from you for importing this item from other countries. 
 

Note: Any Import or export duties and the cost of dispatching for remote areas, will be borne by the buyer, because it is difficult to know all country's custom duty or remote area before shipping the item.
 
4. Please Note buyers from some of the countries may need to contact us before making payment.You may be requested to pay extra shipping cost charged by shipping company otherwise order may be cancelled automatically due to insufficient payment for shipping. We need to revise your invoice before your payment please...

 

(1) Taking photos and sending it via eBay Message Box. Missing item or get wrong item or damaged items, or the item seams can not work well, please keep all the items in original condition, make all the items together with packing, then take some photos of them and send us the photos by message box.
 
(2) How we will react? We will investigate the case and may send you the missing item or replacement or refund upon the situation of the case. (sometimes you may be requested to return the incorrect item).Or if it is not seller's error, buyer may need to cover the returning cost.
 
(3) Valid time for returning. Please contact us within 7 days upon receiving the package.All items must be returned within 30 days of purchasing the item.
Warranty: 3-24 months warranty is provided to our products. The length of the warranty depends on the nature of the products. Please contact us if you are wondering about how the warranty works for your item.
 
Contact: Do please contact us before leaving any negative feedback or Opening any kind of case. We promise to achieve your 100% satisfaction. But negative feedback actually can not solve any problem. Thank you so much for your kindness and understanding.
 
Beijing time :AM 8:00 -PM 8: 00 
PushAuction