CONTEC NEW BRAND MS400 MULTI-PARAMETER PATIENT SIMULATOR,ECG SIMULATOR

              
Introduction

MS400 Multiparameter Simulator is a portable device, features in  small volume and light weight. It can simulate accurately 12-lead ECG,  Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested  in where the monitor is used.

Features 

Simulate 35 kinds of arrhythmia (including Atrial, Ventricular,  Premature Beat and Conduction Defects) and pacemaker waveforms (including  Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture,  Non Function).
Simulate four-channel IBP data.
Simulate respiration signal with adjustable respiration rate, impedance and  baseline impedance, and three kinds of apnea data.
Simulate four kinds of temperature data.
Simulate square wave, triangle wave, pulse wave and sine wave with  adjustable frequency.
Simulate standard ECG calibration, adult and pediatric ECG signal.
ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG  database, other ECG database and user-defined waveform data stored in TF card  can be displayed by the simulator and exported to the equipments to be  tested.
Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy  to operate.
Power supply: rechargeable lithium battery or linear adapter, which reduces  interference.
Optional operation modes: keys and touch screen. 
Parameters: 

ECG
Conventional: All leads have the same voltage with  the II-lead as the reference
Amplitude: 0.5,1.0,1.5 and 2.0mV
ECG Rate:  15,20,25,30,40,60,80,100,120,140,160,180
200,220,240,260,280,300,320,340 and 350  BPM
ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV
Arrhythmia
Atrial: Atrial Fib(coarse), Atrial fib(fine),  Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm,  Supraventricular Tachycardia
Ventricular: Vent Fib (coarse), Vent Fib (fine),  PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy,  Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
Premature  Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus,  PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC
Conduction  Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart  Block, Right Bundle Branch Block, Left Bundle Branch Block
Four IBP Channels
The default: 00/00mmHg
Dynamic  IBP(unit: mmHg)
Channel 1:
Artery: 120/80
Radial: 120/80
Left Ventricle: 120/00
Right  Ventricle: 25/00
Channel 2:

Artery: 120/80
Radial: 120/80
Left Ventricle: 120/00
Right  Atrium(CVP): 15/10
Right Ventricle: 25/00
Pulmonary Artery:  25/10
Pulmonary Wedge: 10/2
Left Atrium: 14/4
Channel 3:

Artery: 120/80
Radial: 120/80
Left Ventricle: 120/00
Right  Atrium(CVP): 15/10
Right Ventricle: 25/00
Pulmonary Artery:  25/10
Pulmonary Wedge: 10/2
Left Atrium: 14/4
Channel 4:
Auto  Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
Man  Swan-Ganz: press ENTER key to change every time
Static-Pressure  Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100,  150, 200 and 250mmHg
Channel 3: 0, 20, 40, 60, 80 and 100mmHg
Channel 4:  P4 tracks the static pressure levels of P3

Respiration
Respiration Rate: 0 (Apnea), 15, 20, 30, 40,  60, 80, 100, 120 and 150 R/MIN
Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
Baseline  impedance: 500, 1000, 1500, 2000Ω
Apnea: 12 s, 22 s, 32 s
Temperature 
Four temperature: 0℃(32°F), 24℃( 75°F),  37℃(98.6°F), 40℃(104°F)
Accessories

Standard accessories 9V/1A(CE) power adapter, an User manual, a  packaging box, a plastic packaging.
Optional accessories a power  adapter(15V/1A)(UL), a power adapter(15V/1A), a temperature cable, an IBP cable,  a CD disk(including a case conversion software) 

Physical  characteristic

Dimension 18.86 cm(L)×12.50 cm(W)×4.32 cm(H)
Net  weight about 1.4kg

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.