CMS6000C
               
Introduction 
The monitor has abundant monitoring functions and is used for monitoring of adult, pediatric and neonate. User may select different parameter configurations according to different requirements. It displays real-time data and waveform by 8'' TFT color LCD, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously. 48mm thermal printer is optional. In addition, it can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system. 
This device can monitor such parameters as ECG, SpO2, PR, NIBP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving.

Functions
Standard parameters: ECG, RESP, SpO2, PR,
1)ECG   Heart rate(HR)
      ECG waveform 
      Arrhythmia and ST-segment analysis
2)RESP   Respiration rate(RR)
      Respiration waveform
3)SpO2   Oxygen saturation(SpO2)
      Plethysmogram(PLETH) waveform
      Pulse rate(PR)
      Bar graph
4)NIBP   Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP   T1, T2, TD
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.

Features
1)8'' TFT color LCD, multi-language interface.
2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
3)All-round monitor for adult, pediatric and neonate.
4)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
5)Waveform, parameter color and location can be set optionally.
6)Operation mode: keys and buttons.
7)Display up to 8-channel waveform on one screen.
8)Display 7-lead ECG waveform on one screen, and with ECG step function.
9)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
10)HRV analysis function.
11)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
12)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
13)Drug concentration calculation and titration table functions. 
14)Print trend table data with one-key.
15)Connect to Central Monitoring System by 3G, WiFi or wired mode.
16)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
17)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).

Performance
▲ECG
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, 2-channel
3-lead, 1-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR: 
Measurement and alarm range: 15~350bpm
Accuracy: ±1% or ±1bpm, whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement and alarm range: -2.0mV~+2.0mV
Accuracy: -0.8mV~+0.8mV  ±0.04mv or ±10%, whichever is greater 
Other range: unspecified 
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Pacemaker: yes
RESPIRATION
Method: R-F(RA-LL) Impedance 
Respiration rate: 
Measurement and alarm range: 0~150rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm: 10~40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
▲NIBP
Method: Oscillometry
Mode: Manual/AUTO/STAT 
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal standard deviation: 8mmHg
Over-pressure protection:
Adult mode: 297±3 mmHg
 Pediatric mode: 240±3 mmHg
 Neonatal mode: 147±3 mmHg
▲SpO2
Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%; 
0%~69%: unspecified 
PR
Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater

Accessories
Adult fingertip SpO2 probe (5-pin)
Adult NIBP cuff 
NIBP extension tube
ECG lead cable
ECG electrode
Power adapter
Power cord 
User Manual 

Physical characteristic
Dimension: 235 mm(L) × 141 mm(W) × 222 mm(H)
Weight: 2.5 Kg

Buy Safe Product

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.

Shipment

1. We will ship the item within 48 hours after receiving your payment, please kindly leave your detail shipping address and telephone number on ebay, both are very important for the shipment,thank you.

2.To USA buyers,we will ship the machine directly from Illinois,united states. 2-5 days arrival.To other counteries' buyers,we will ship it from our factory,China Warehouse. 1-3 weeks delivery. 

3.We will upload the tracking number after shipment,you can track it online.If you can't track it,please kindly contact me for help.
4. If you haven't received the item after 3 weeks of your payment, please contact me immediately! 
Email/MSN:contecmandyathotmail.com

Terms Of Sale

1.If you have a defective item, you want to return or discount. Please contact us within 14 days from you receive the shipment.All return items must be returned with its original packaging and accessories. Customer is responsible for shipping charges on returned items.

2.We will refund the money to you when we get the return items. Or replace item for you. We will deal with the refund in 2 business days when we get the infomation from you.Please read our trade Policy before buy , if you don't agree our trade policy please don't buy it.

3.Sometimes there's some delay for the delivery of your package,Please kindly contact us for more information.Please don't open any cases nor return requests on both ebay and paypal,and please don't leave me any negative nor neutral feedback on ebay.I will try my best to give you a satisfied solution.  

Thanks for your purchase!
ibay365