Green Mode |
CEC, DoE Level VI, Energy Star, ErP Stage 2, CoC Tier 2, NRCan & GEMS Level VI |
No Load Power Consumption Less Than 0.15W |
O/P Voltage | O/P Current | Watt |
19.0V | 8.40A | 160W |
Input |
Voltage | 100-240 VAC |
Line Frequency | 50-60Hz |
Current | 2.2A Max. |
Protection | Internal Primary Current Fuse |
Configuration | IEC60320/C14 |
Output |
Load Regulation | ± 5%(Typical) |
Ripple & Noise | 1% Vp-p Max. for Output Voltage @ Full Load |
Transient Response | 0.5mS for 50% Load Change Typical |
Hold-up time | 10mS @ Full Load |
Protection | Short Circuit Protection/ Over Voltage Protection/ Over Current Protection/ Over Temperature Protection |
Ferrite Core | Included |
Safety Approvals |
CB / UL / cUL / FCC / GS / CE / PSE / BSMI / RCM / CCC |
Electrical |
Topology | LLC |
Dielectric Withstand | 3000 VAC Primary - Secondary |
Leakage Current | 3.5mA @ 3Pin |
Efficiency | DoE Level VI, Energy Star, ErP Stage 2, CoC Tier 2, NRCan & GEMS Level VI Certified |
EMC Standards | EN55032 |
EN61000-3-2,3 |
EN55024 |
MTBF | 300,000 Calculated Hours at 25°C, by Telcordia SR-332 |
Outlet | C14 |
DC Jack | 7.5mm (outer) 5.0mm (inner) |
Environmental |
Operating Temperature | 0 to +40°C |
Storage Temperature | -20 to +80°C |
Relative Humidity | Operating: 20 to 80% RH |
Storage: 10 to 90% RH |
Cooling | Natural Convection Cooling |
Mechanical |
Case Dimension | L 159 x W 51 x H 31 (mm) |
Weight | 700g (Ref.) |