This equipment has been tested. Please refer to the tests/remarks section below for details.
SERIAL NO: 0756-03024
MANUFACTURER DESCRIPTION:
The Eaton / Ailtech NM-37/57 EMI / Field Measuring Receiver performs manual or programmable EMI emission measurements from 30 MHz to 1 GHz.
TESTS/REMARKS:
- 30-57, OK
- 55-105, FAULTY – band faults no receive. Meter band LED’s on 55-105 Faulty/Don’t light
- 101-192, OK
- 186-292, OK
- 285-445, OK
- 430-620, OK
- 600-825, OK
- 800-1000, OK
- Frequency Meter sticks on full scale, slight tap needed to release
- Case / body in good condition
HEAVY / BULKY. COLLECTION ONLY FROM BANBURY (OX15)