![](https://ae01.alicdn.com/kf/Hc7c5f729951e4b87815fb2ba70d192e3p.jpg)
1.This
spindle is built-in type spindle motor, built-in three asynchronous
motors,by the inverter control.As the spindle has a compact
structure,high power, big torque, small vibration, low noise
characteristics,so it can achieve high speed,high powe cutting,high
recision and high stability operation.
2.The
bearing of spindle use grease lubricated angular to contact
bearings,can be achieved lifelong lubricating within the life cycle.
3.This
spindle uses air cooling to cool the motor and front and rear bearings.
The wind is provided by the fan at the rear end, from the rear of the
spindle through the inner and outer air slots directly to the front of
the spindle, there by taking away the heat generated by the high-speed
rotation of the spindle, achieving thermal balance, and keeping the
temperature of the electric spindle within a certain value.
4.The
spindle built-in PTC 140 temperature sensor(Technical parameters are
visible in other sections of this specification),you can read it anytime
if you need to protect the motor temperature.
5. The tool clamping methods:this spindle built-in automatic tool change
device,shank form is BT30.
Please
note that when stopping the spindle, you need to wait until the spindle
is stopped before releasing the tool holder, so as to avoid causing the
spindle and the tool mechanism to be connected together and cannot be
separated. When loosening the tool and broaching the tool, you need to
return the air, and pls keep the air intake and return air during the
whole work.
Spindle installation explanation
1.Fan
cooling system description When the spindle rotates, the rear fan
system must be started to ensure the correct supply voltage and the
supply voltage is 12V.
2.Air sealing control (AS)
In
order to prevent water or impurities enters internal of the
spindle,spindle will have gas sealing device,the gas seal machine must
be started start with the machine at the same time. And the need to go
through multi-stage filtration.
3.Compressed gas quality requirements
The quality requirement of gas which is used in gas seals:
Oil content:﹤0.01mg/m³
solid particle:﹤5µ m
Pressure dew point:﹤7.5℃(0.7MPa)
3. Running-in program instructions
Only
all monitoring issued no failures operational signals,at the same
time,all safety devices have been installed and working properly,then
allow start spindle. Note: new or spindle which is not used for a long
time must to be running slowly.First,start run spindle for half an hour
as 25% of the maximum speed,then increase to 50% of the maximum speed,to
run 15 minutes,finally,
increase
to maximum speed.It’s need to check the temperature of the spindle
during the whole process, spindle will get hot, but not hot hand, if the
spindle becomes hot, pls stop the operation and contact our customer
service department.