1.Description
2.What's Included?
3.Features&Highlights
1. Palm centrifuge
The instrument is simple to operate, small in size, light in weight and low in noise. Easy to maintain and other features.
2. Intelligent digital display
Working principle: The instrument is controlled by a microcomputer and directly driven by an AC brushless motor.
3. Smooth operation, stable speed, timing adjustment
This instrument is controlled by a microcomputer and directly driven by an AC brushless motor. It adopts a special shock absorption system to achieve various protection functions such as automatic balance, and has advanced centrifugal function. The time setting is accurate, in minutes.
4. High-precision separation
Serum separation, fat separation
4.Weights&Dimensions
5.Specifications
Steps for usage:
1 Place the sample in an equal amount in the test tube, and put it in the rotor symmetrically.
2 After connecting the instrument to the power supply, turn on the power switch on the back of the instrument.
3 After the power switch is turned on, the displayed speed is the maximum speed. If the timing type is selected, you can press the left button "TIME" to set the timing, and use the up and down keys to set the required time.
4 Press the right button "START" to start working, and the whole machine will run. (If you need to stop in the middle, please press the right button "START" to stop working). The instrument runs to the set time and will stop automatically. Only then can you open the lid and take out the sample The tube is centrifuged and used.
5 After the instrument stops, take out the sample, turn off the power switch, and unplug the plug.
Precautions:
1 Make sure that the instrument is placed on a firm, level floor or test bench, and the base should be in contact with the bench to be evenly stressed to avoid vibration.
2 The centrifuge tube must be tightly covered to prevent the liquid in the tube from corroding the centrifuge.
3 If you accidentally spill liquid on the centrifuge, please clean it in time to avoid corrosion.
4 When replacing or disassembling the centrifuge rotor, the centrifuge power supply must be turned off to avoid danger.
5 When the whole machine is running, do not open the cover to avoid danger. Do not move the centrifuge when the rotor is spinning.
6 If you need to stop working due to some special reasons, press the stop button to end the running work.
Statement (FDA, ARTG)
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and
state and local regulatory agencies. If the item is subject to FDA regulation,
I will verify your status as an authorized purchaser of this item before shipping of the item.
If you have questions about legal obligations regarding sales of medical devices,
you should consult with the FDA's Center for Devices and Radiological Health:
https://www.fda.gov/cdrh/devadvice/
https://www.fda.gov/cdrh/industry/support/index.html
Thank you for your cooperation.