A cautery machine with a digital touchscreen, 400-watt power, vessel sealing system, and normal saline bipolar TURP (Transurethral Resection of the Prostate) capabilities is a sophisticated medical device used in various surgical procedures. Here's a breakdown of its features and uses:
Digital Touchscreen:
400 Watt Power Output:
Vessel Sealing System:
Normal Saline Bipolar TURP:
General Surgery:
Gynecological Surgery:
Urological Surgery:
Orthopedic Surgery:
ENT Surgery:
Standard Accessories:-
1. Double Switch Foot Paddle 2Pc
2. Bipolar Forceps 1Pc
3. Bipolar Cable Cord 1Pc
4. Chuck Handle 1Pc
5. Disposable Cautery Pencil 1Pc
6. Needle Set 1Set
7. Tip Cleaner 1Pc
8. Patient Plate 1Pc
9. Patient Plate Cable Cord 1Pc
Product
Features: -
CUT
MODE
PURE CUT - A high-frequency alternating current
yields smooth, rapid cuts that evoke little to no hemostasis.
BLEND 1 - Preset blended cut modes give the surgeon
varying degrees of hemostasis in cut mode.
BLEND 2 - The mode is used for the vaporization of
prostatic tissue or any fat tissue. The higher output wattage gives fast
cutting eect of the tissue.
ENDOCUT - The mode is used to automatically control
cut system to reduce the complication rate of endoscopic sphincterotomy (EST)
and serum hyperamylasemia after EST compared to the conventional blended cut
mode.
COAG MODE
SPRAY - Spray output is made for direct coagulation
at the tissue with spark. Above spark does not give any cutting effect as its
crest factor is high.
FORCE - This mode is a greater degree of homeostasis
and covers all demands of standard coagulation. This produces the fine tune
waveform that creates superficial resistance in the tissue resulting in
superior coagulation where the tissue destroyed by hyper evaporation. Electro
Surgical Generator
FULGURATE - Sparking the tissue to lead to
coagulation. There is no tissue-electrode contact; rather, voltage is raised in
order to incite a spark between electrodes in order to coagulate the tissue in
between
DESICCATE - Coagulation in which the active electrode
is in direct contact with the tissue is referred to as desiccation and is the
type of coagulation used in most surgeries It ensures pinpoint desiccation with
less destruction of peripheral tissue.
BIPOLAR
& SEAL
BI-COAG - For highly precise control over coagulation
process and privations of carbonization.
BI-CUT - Bipolar CUT technology lets you nearly
eliminate excessive current, even during precision cutting in minute tissue
structure.
SEAL - Mode provides unique combination of pressure
& energy to create vessel fussion, leaving no foreign material behind.
Easemed designed special feature that seal as well as cut simultaneously used
with help of sealer instrument using programme 5 & 6 for surgery.
BITUR - The advantage of bipolar TURP is that saline
can be used during the procedure which is much safe option, vertually
eliminating the risk of TURP syndrome as a result, larger and more complicated
prostate gland can be treated with Bipolar TURP mode.
Salient
Features: -
• 99 User settable program mode
• Frequency: 480khz (Monopolar/TURP)
• Frequency: 1 Mhz (Seal Mode)
• Display: 7 in LCD touchscreen display
• Input Supply Voltage - 100 V / 230 VAC (+/-15%) 50 Khz