Up for sale is a brand new in the box Fluke 376 FC Fluke connect meter with all accessories & manuals. This awesome meter is able to sync with your apple or android Bluetooth device (when you download the app) and log data and let you remotely monitor any changes in voltage, amperage, etc. The meter pictured is the actual meter you will receive. Below is all the data from the Fluke website:-
The Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes.
Additionally, the Fluke 376 includes the new iFlex™ flexible current probe, which expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter.
Safety Conformance
EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV
Features and benefits |
|
Safety conformance |
What’s the difference between the clamp meter models?
Fluke-365 | Fluke-373 | Fluke-374 | Fluke-375 | Fluke-376 | Fluke-381 | |
Measure ac current | 200.0 A | 600.0 A | 600.0 A | 600.0 A | 999.9 A | 999.9 A |
Measure ac current via iFlex | 2500 A | 2500 A | 2500 A | 2500 A | ||
Measure ac voltage | 600.0 V | 600.0 V | 600.0 V | 600.0 V | 1000.0 V | 1000.0 V |
Measure continuity | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω |
Measure dc current | 200.0 A | 600.0 A | 600.0 A | 999.9 A | 999.9 A | |
Measure dc voltage | 600.0 V | 600.0 V | 600.0 V | 1000.0 V | 1000.0 V | |
Measure resistance | 6,000 Ω | 6,000 Ω | 6,000 Ω | 60k Ω | 60k Ω | 60k Ω |
Measure frequency | 500 Hz | 500 Hz | 500 Hz | |||
Measure inrush | 100 mS | 100 mS | 100 mS | 100 mS | ||
Work in poorly lit areas | Backlight | Backlight | Backlight | Backlight | Backlight | Backlight |
Measure non-linear loads | True-rms | True-rms | True-rms | True-rms | True-rms | True-rms |
Electrical Specifications | ||||
AC Current via Jaw | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) | |||
Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 | |||
AC Current via Flexible Current Probe | ||||
Range | 2500 A | |||
Resolution | 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) | |||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |||
Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | |||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% | |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
DC Current | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits | |||
AC Voltage | ||||
Range | 1000 V | |||
Resolution | 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) | |||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
DC Voltage | ||||
Range | 1000 V | |||
Resolution | 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) | |||
Accuracy | 1% ± 5 digits | |||
mV dc | ||||
Range | 500.0 mV | |||
Resolution | 0.1 mV | |||
Accuracy | 1% ± 5 digits | |||
Frequency via Jaw | ||||
Range | 5.0 - 500.0 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 10 Hz, ≥10 A | |||
10 – 100 Hz, ≥5 A | ||||
100 – 500 Hz, ≥10 A | ||||
Frequency via Flexible Current Probe | ||||
Range | 5.0 - 500.0 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 20 Hz, ≥ 25 A | |||
20 – 100 Hz, ≥ 20 A | ||||
100 – 500 Hz, ≥ 25 A | ||||
Resistance | ||||
Range | 60 kΩ | |||
Resolution | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) | |||
Accuracy | 1% ± 5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) | |||
Accuracy | 1% ± 4 digits | |||
Mechanical Specifications | ||||
Size (L x W x H) | 246 mm x 83 m x 43 mm | |||
Weight | 388 g | |||
Jaw Opening | 34 mm | |||
Flexible Current Probe Diameter | 7.5 mm | |||
Flexible Current Probe Cable Length (head to electronics connector) | 1.8 m | |||
Environmental Specifications | ||||
Operating Temperature | 10°C – +50°C | |||
Storage Temp | -40°C – +60°C | |||
Operating Humidity | Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) | |||
Operating Altitude | 3000 meters | |||
Storage Altitude | 12,000 meters | |||
EMC | EN 61326-1:2006 | |||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | |||
Safety Specifications | ||||
Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 | |||
Agency Approvals | ||||
Batteries | 2 AA, NEDA 15A, IEC LR6 |