无标题文档
Title:

15MHZ Signal Generator Digital Dual Channel DDS Signal Generator Frequency Meter

Features:
  • Adopt 320*240 2.4" TFT color LCD display, simultaneously display parameters of CH1 and CH2.
  • Ability to reproduce patterns of custom waveform.
  • Use soft silicone keys instead of traditional patch keys, high sensitivity and convenient for operation.
  • The model sold on this link is JDS2900-15M,The maximum sine wave frequency is 15MHz, and the maximum square wave is 15MHz, 266MSa/s sampling rate and 14bits vertical resolution.
  • Completely independent dual channels output, synchronizing operation and adjustable phase difference.
  • 60 groups of arbitrary wave storage function, memory depth of each group is 2048*14bits.
  • High frequency accuracy and resolution: frequency accuracy up to 10^(-6) magnitude, total range frequency resolution is 0.01uHz.
  • High amplitude resolution: the minimum amplitude resolution can reach 1mV, amplitude range is 2mVpp~20Vpp.
  • Duty-cycle of each channel can be adjusted independently, the adjusting resolution is 0.1%.
  • Sweep function: linear sweep and logarithmic sweep functions; 0.1s-999.9s sweep time; forward, backward and roundtrip sweep directions.
  • With pulse trains burst output function: allow the unit output 1~1048575 arbitrary pulse trains.
  • Measurement functions: can measure signal frequency, cycle, positive/negative pulse width and duty cycle; 1Hz~100MHz frequency range.
  • -9.99V~9.99V DC offset range, offset resolution: 0.01V.
  • With digital signal output function, CMOS output range 0~10V.
  • Storage feature: can store 100 groups of parameters set by the user and extract at any time.
  • Counter function: with DC and AC coupling modes.
  • Arbitrary wave editing function: user can edit arbitrary wave on PC and then download to output from the instrument.
  • Communication function: the PC can be used to control the instrument.
  • With output short-circuit protection: all signal output can work 60s under load short-circuit condition.
Frequency specifications:
  • Sine frequency range: 0~15MHz
  • Square frequency range: 0~15 MHz
  • Triangle frequency range: 0~15 MHz
  • Pulse frequency range: 0~6 MHz
  • TTL digital frequency range: 0~6 MHz
  • Arbitrary wave frequency range: 0~6 MHz
  • Square rise time: ≤25nS
  • Pulse width adjustment range: 100nS - 4000S
  • Frequency accuracy: ±20 ppm
  • Frequency stability: ±1 ppm/3h
Waveform specifications:
  • Waveform:   Sine, square, triangle, pulse (duty-cycle correction, pulse width and cycle time adjustable), arbitrary wave, CMOS, DC level, half-wave, full-wave, pos-ladder, neg-Ladder, noise, exponential rise, exponential fall, tone, cink pulse, lorentz pulse, and 60 kinds user-defined waveforms.
  • Waveform vertical resolution:   14 bits
  • Waveform sampling rate:   266 MSa/s
  • Waveform length:   2048 points
  • Sine - Harmonic suppression:   ≥45dBc(<1 MHz); ≥40dBc(1 MHz~20 MHz)
  • Sine - Total harmonic distortion:   <0.8%(20 Hz~20 kHz,0dBm)
  • Square and Pulse - Overshoot (Square):   ≤5%
  • Square and Pulse - Duty-cycle range(Pulse):   0.1 - 99.9%
  • Ramp wave – Linearity:   ≥98%(0.01 Hz~10 kHz)
Output specifications:
  • Amplitude range:  Frequency<10MHz,0-20VPP; Frequency>10 MHz, 0 - 10Vpp.
  • Amplitude resolution:   1 mV
  • Amplitude stability:   ±0.5%/5 h
  • Amplitude flatness:  ±5%(<10 MHz); ±10%(>10 MHz)
Waveform specifications:
  • Output impedance:   50Ω±10%(typical)
  • Protection:   Short circuit 60S will not be damaged
DC Offset:
  • Offset adjusting range:   Output Amplitude>2V,-9.99V~9.99V;0.2V<Output Amplitude≤2V,-2.5V~2.5V;0<Output amplitude≤0.2V, -0.25V~0.25V;
  • Offset resolution:   0.01 V
Phase specifications:
  • Phase adjusting range:   0~359.9o
  • Phase resolution:   0.1o
TTL/COMS Output:
  • Low level:   <0.3 V
  • High level:   1 - 10 V
  • Level rise/fall time:   ≤20ns
External measurement functions:
  • Frequency meter function - Frequency measurement range:   1 Hz~100 MHz
  • Frequency meter function - Measurement accuracy:   Gate time continuously adjusted between 0.01S~10s
  • Counter function - Counting region:   0-4294967295
  • Counter function - Coupled mode:   2 Coupling modes, DC and AC
  • Counter function - Counting mode:   Manual operation.
  • Input signal voltage range:    2 – 20 Vpp
  • Pulse width measurement:    0.01us (resolution), 20s (MAX measuring time)
  • Period measurement:   0.01us (resolution), 20s (MAX measuring time)

 

Sweep Functions:
  • Sweep channel:   CH1 or CH2
  • Sweep type:   Linear sweep, log sweep
  • Sweep time:   0.1s~999.9s
  • Setting range:   Arbitrarily set between start point and stop points
  • Sweep direction:   Forward, backward and round trip
General technical parameters:
  • Display type:   2.4 inch TFT color LCD
  • Storage and loading - Quantity:   100 groups
  • Storage and loading – Location:   00 to 99(extract 00 place data at default boost state)
  • Arbitrary wave – quantity:   1 to 60, totally 60 groups (default boost 15 groups)
  • Interface mode:   USB to serial interface
  • Extension interface:   There is serial interface of TTL level mode to be convenient for secondary development.
  • Communication speed - Adopt standard:   115200 bps
  • Communication protocol - Adopt command:   line mode, open protocol
  • Power supply:   DC 5 V±0.5 V
  • Manufacturing process:   Surface-mount technology, large scale integrated circuit, high reliability, long service life
  • The user can set ON or OFF by procedure
  • Operating characteristics: Full button operation, knob continuous adjustment
  • Environmental conditions: 860 g
  • Size: 23 x 15 x 9.5 cm
Package:
  • 1 * DDS Signal Generato
  • 1 * CD
  • 1 * Power Adapter(In:100~240V~50/60Hz,Out:5.0V-2.0A)
  • 1 * USB Data Cable
  • 1 * BNC-BNC Cable
  • 2 * BNC-Clip Cable
  • 1 * Instruction manual

 