The Fingertip
Pulse Oximeter is registered on the Australian Register of Therapeutic
Goods (ARTG) with the code 197923, and certified by FDA of United States
and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K
Approved.
Model:CMS50F with Software
Instructions
Principle
of the CMS50F Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin
Inspection Technology is adopted in accordance with Capacity Pulse
Scanning & Recording Technology,the Pulse Oximeter can be used in
measuring the pulse oxygen saturation and pulse rate through finger.The
product is suitable for being used in family, hospital, oxygen bar,
community healthcare, physical care in sports (It can be used before or
after doing sports, and it is not recommended to use the device during
the process of having sport) and etc.
Major Features
- Small in volume、light in weight and convenient in carrying
- Operation of the product is simple ,low power consumption
- SpO2 value display
- Pulse rate value display, bar graph display
- Pulse waveform display
- The display mode can be changed
- Screen brightness can be changed
- A pulse rate sound indication
- With measured data overruns limits and low-voltage alarm function,the upper/down alarm range can be adjustable
- With clock function
- Battery capacity indication
- Low-voltage
indication: low-voltage indicator appears before working abnormally
which is due to low-voltage, and with alarm function
- With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
- Real-time data can be transmitted to computers
- Connected with an external oximeter probe
- Wireless communication function(CMS50FW)
Main performance
- Display Mode: 65K Color OLED display
- Screen Resolution: 128*96
- SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
- Accuracy: 70%~100%: ±2% ,Below 70% unspecified.
- PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
- Accuracy: ±2bpm or ±2% (select larger)
- Measurement Performance in Weak Filling Condition:
- SpO2
and pulse rate can be shown correctly when pulse-filling ratio is 0.4%.
SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
- Resistance
to surrounding light: The deviation between the value measured in the
condition of man-made light or indoor natural light and that of darkroom
is less than ±1%.
- Power Consumption: less than 100mA
- Voltage: DC 3.6V~4.2V
- Power Supply: Voltage 3.7 rechargeable lithium battery × 1
- Battery working hour: 20 hours
- Battery working life: Charge and discharge no less than 500 times.
- Safety Type: Interior Battery,BF Type
Accessories
- A user manual
- A USB line
- A wristband
- An adult-oximeter probe