Product features:
    Wide voltage power supply (6~30V) support micro USB 5.0V power supply or TYPE-C interface power supply 2 kinds of interfaces to choose from;
    clear and simple interface, powerful functions;
    has a key emergency stop function (STOP key) with reverse connection protection, reverse connection does not burn;
    can set different OP, CL, LOP parameters, which are independent of each other and saved separately
    All set parameters are automatically saved by power-down.
     
    Style I:
    Micro USB interface:
    Product parameters:
    1: Operating voltage: 6 - 30V, support microUSB data 5.0V power supply
    2: trigger source: high level (3.0V-24V), with optocoupler isolation, can improve the anti-interference ability of the system (customers can also do empty common point).
    3: Output function: can control DC 30VDC 5A or 5A 220VAC devices.
    4: quiescent current: 20 mA; operating current: 50 mA
    5: life: more than 100,000 times; operating temperature: -40-85 ℃; size
    6: Optocoupler isolation, enhanced anti-interference ability, industrial grade motherboard.
    Special Note: Relay output is a passive contact, just a switch.
     
    Style II:
    USB Type-C interface:
    Operating voltage: 6 - 30V
    Support: TYPE-C 5.0V power supply
    trigger signal source: high level trigger (3.0V-24V) signal ground and system ground is not common ground to improve the system's anti-interference ability (can also be shorted to common ground by themselves)
    Output capacity: can control equipment within 30V5A DC or 220V5A AC
    Static current: 20mA Working current: 50mA
    Service life: greater than 100,000 times;
    Operating temperature: -40-85℃;;
    with optocoupler isolation, enhanced anti-interference capability, industrial-grade circuit board, set parameters after power failure forever
    memory.
    Working mode:
    P1: signal triggered, the relay conducts OP time, and then disconnects; in OP time, the following operation
    P1.1: signal re-triggered invalid
    P1.2: Signal triggers again to re-timer
    P1.3: the signal triggers again to reset, the relay disconnects and stops timing
    P-2: give trigger signal, relay disconnect CL time after which the relay conducts OP time, and disconnect the relay after timing is completed
    P3.1: give the trigger signal, after the relay conducts OP time, the relay disconnects CL time, then cycle the above action, give the signal again within the cycle, the relay disconnects and stops timing; the number of cycles (LOP) can be set;
    P3.2: after power on without trigger signal, relay on OP time, relay off CL time, cycle the above action; the number of cycles (LOP) can be set;
    P-4: Signal hold function If there is a trigger signal, the timing is cleared and the relay is kept on; when the signal disappears, the relay is disconnected after the timing OP; during the timing period, there is a signal again, the timing is cleared;
    Caution:
    1, pay attention to the wiring according to the diagram, do not connect the wrong.
    2、This document only represents the product parameters at the time of editing, and any later changes without notice.
    3, the relay output is a passive contact, not charged output, control the role of a line on and off.
    Timing range:
    0.1 seconds (minimum) ~ 999 minutes (maximum) continuously adjustable
    How to choose the timing range:
    Select the timing range by short pressing STOP after setting the parameter value in the mode selection interface;
    XXX. decimal point in the single digit, timing range: 1 second ~ 999 seconds
    XX.X The decimal point is in the tenth place, timing range: 0.1sec~99.9sec
    X.X.X. The decimal point is fully lit, timing range: 1 minute ~ 999 minutes
    For example, if you want to set OP is 3.2 seconds, then move the decimal point to the tenth position, and the digital tube will display 03.2
    Parameter description: OP on time, CL off time, LOP cycle times (1-999 times, "---" represents infinite cycles)
    these parameters are independent of each other, but each mode shares these parameters, for example, in P1.1 set the on-time OP is 5 seconds, the user wants to switch to P1.2 mode, then when entering P1.2 to set the corresponding parameters, OP will also be 5 seconds;
    A short press on SET in the main interface (display 000) will display OP (CL, LOP) and the corresponding time XXX;
    If there is only OP (e.g. mode P1.1, P1.2, P1.3) time in the mode, then short press SET key will display only OP and the corresponding time.
    If the mode has OP, CL, LOP (e.g. mode P3.1, P3.2) then a short press of the SET key will display OP and the corresponding time, CL and the corresponding time, LOP and the corresponding times;
    After setting the mode, you can easily view the parameters set in the current mode by short pressing SET in the main interface.
    How to set the parameters:
    1. first determine the operating mode of the relay;
    2. according to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), then enter the main interface, "press and release SET key for 2 seconds" to enter the mode selection interface, select the mode to be set by short pressing UP, DOWN button (P1.1 ~ P-4) ~P-4). 3;
    3. After selecting the mode to be set (e.g. P3.2), short press the SET button to set the corresponding parameters.
    At this time, the parameter to be set will flash (OP on time, CL off time, LOP cycle times ("---" represents infinite cycles)), adjust the parameter value by UP, DOWN, support long press (fast increase or decrease) and short press (increase or decrease by 1 unit); after setting the parameter value, select the decimal point by short press STOP key to select the decimal point position, select the timing range (corresponding time 0.1 seconds ~ 999 minutes); short press SET key to set the next parameter of the current mode, the process as above;
    4. after setting the parameters of the selected mode, long press SET key for 2 seconds and then release, the current set mode will flash down, then return to the main interface, set the parameters successfully;
    Main interface: the relay does not work in the state of "000" (no decimal point), the relay works with a decimal point;
    Mode selection interface: press and hold SET to enter, after setting, press and hold SET to exit and return to the main interface;
    Relay enable modes:
    1. ON : Relay is allowed to be on during OP on time;
    2. OFF : Relay is forbidden to be on, always off;
    Short press STOP button in the main interface to switch between ON and OFF, the current state will flash and then return to the main interface. (This function is the emergency stop function, a key to disconnect the closed relay)
     
    Package includes:
    1* Relay switch module

Package includes:

5V Delay Relay Module Power Off Trigger Delay Cycle Timer Switch Micro Type C

 

Payment

Payment

Payable To

Note

PayPal

All payments are due within 7 days of the close of auction. Failing to do so, non-paying bidders will be reported to eBay.

Shipping Policy

Delivery Time

We ship to worldwide, it usually takes 10-30 Business Days to delivery.

Shipping address

We ship to your PayPal address. Please, make sure to provide us with correct, precise, and detailed shipping Address.

Send Time

Items will be shipped within 1 to 3 business days upon payment received or cleared.

Note

If you don't receive items over 30 business days, please notify us via eBay message.

Return Policy
We appreciate your business and offer an instant 7 days return policy.(7 days after receive the item). The returned item has to be in its original condition. We are able to refund your money without shipping cost.  
Contact us
For anything about product, price, shipping or order status, please contact us via eBay message.
We love positive feedback and 5 scores DSR. We will leave it for everyone that leaves it for us.  

DataCaciques