The CEM DT-613 Digital Thermometers are portable hand held and compact meters designed to use an external K type thermocouple as a temperature sensor. Temperature indication follows N.I.S.T and I.E.C. 584 temperature/voltage tables for K type thermocouples. They have user selectable °C/°F/K scales and resolution of 0.1/1 °C/°F/K.
The CEM DT-613 Digital Thermometers are portable hand held and compact meters designed to use an external K type thermocouple as a temperature sensor. Temperature indication follows N.I.S.T and I.E.C. 584 temperature/voltage tables for K type thermocouples. They have user selectable °C/°F/K scales and resolution of 0.1/1 °C/°F/K.
3-1/2 Digits Backlit LCD Display
9V Battery Operated
User Selectable °C/°F/K scales
Type K input thermometers
dual input
Differential Temperature T1-T2 can be measured
Electronic Offset function allows compensation of thermocouple errors to maximise overall accuracy.
Auto Power Off Mode
Max Hold and Data Hold
Specifications |
|
|
|
|
Function | Range | 610B | 612 | 613 |
Temperature | -50~1300ºC | Single Input | Dual Inputs | Dual Inputs |
-58~2000ºF | ||||
Resolution | 0.1o or 1o | * | * | * |
Specifications(613) | ||||
Range: -200ºC to 1372ºC (-328ºF to 2501ºF) | Basic Accuracy | |||
T1, T2 Above -100ºC (-148ºF) | ±[0.15%rdg+1ºC(1.8ºF)] | |||
T1, T2 Below -100ºC (-148ºF) | ±[0.5%rdg+2ºC(3.6ºF)] | |||
T1-T2 | ±[0.5%rdg+1ºC(1.8ºF)] | |||
Type K Temperature Resolution | 0.1ºC/ºF/K<1000º ;1ºC/ºF/K>1000º |