HIOKI digital multimeter DT4256 Most Function General purpose 10A terminals F/S

This product data sheet is originally written in English.


HIOKI digital multimeter DT4256 Most Function General purpose 10A terminals F/S

Description:

Brand: HIOKI
Style: Single item
size: 21.6 x 12.8 x 6.4 cm; 622 g Manufacturer: Hiki Electric
Part number: DT4256
Product Weight: 622 g
Packing size: 21.6 x 12.8 x 6.4 cm; 622 g
Battery: 4 AAA Batteries (Included)
Is Discontinued By Manufacturer: No
Style: Single item
Battery included: Yes
Battery use: No
Battery type: Alkaline
Professional necessities of electricity! Equipped with a wide variety of measurement functions in the standard series with high safety and high-speed response, the multi-active DT4256 can also measure 4-20mA signals.
* DCV basic accuracy +/- 0.3%, standard type of ACV f special 40 to 1 kHz * Low-pass filter 100Hz / 500Hz with harmonic cut * Equipped with automatic automatic discrimination function * Equipped with multifunctional function such as C measurement, frequency measurement * USB communication function for PC measurement (optional) Use) * -10 degree C to 50 degree C and wide operating temperature range DT4256 (general-purpose type with most functions / 10A terminals) * Basic specifications (accuracy guarantee period 1 year) * DMM describes only representative values as basic accuracy because there are many measurement functions and ranges.
[DC voltage] 600.0mV to 1000V, 5 range, basic certainness: +/- 0.3% rdg. +/- 3dgt. [ALTERNATING voltage 40-500Hz] 6.000V to 1000V, 4-range, frequency characteristics: 40Hz to 1kHz, basic certainty: +/- 0.9% rdg. +/- 3dgt. (Effective value retesting, Crest factor 3 or less) [Automatic automatic discrimination] function [resistance] 600.0ohm to 60.00Mohm, 6 range, basic accuracy: +/- 0.7% rdg. +/- 3dgt. [DIRECT CURRENT]6.000A/10.00A, 4-range, Basic certainty: +/- 0.9% rdg. +/- 3dgt. [4-20mA conversion function] yes [ALTERNATING current 40-500Hz] 600.0mA to 10.00A, 3 range, basic certainty: +/- 1.4% rdg. +/- 3dgt. (Effective value retesting, Crest factor 3 or less, frequency response: 40Hz to 1kHz) [AC clamp measurement 40 to 1 kHz] 10.00A to 1000A, 7 range, basic accuracy: +/- 0.9% rdg. +/- 3dgt. add the measurement accuracy of ac clamp (effective value recveal, Crest factor 3 or less) [inspection (500) Hi: AC40V to 600V, Lo: AC80V to 600V [Capacitance] 1.000 microF to 10.00mF, 5 range, basic accuracy: +/- 1.9% rdg. +/- 5dgt. [Frequency] At ACV/ACA: 3 ranges from 99.99Hz (5Hz or more) to 9.999kHz, ACV only: 99.99kHz, basic certainness: +/- 0.1% rdg. +/- 1dgt. Conductive ON threshold: 25ohm or less (buzzer sound, red LED on), conductive OFF threshold: 245ohm or more, response time: 0.5ms or more [diode test] Open voltage: 5.0V or less, measurement current: 0.5mA, forward threshold: 0.15V to 1.5V [Other functions] filter, display value hold, auto hold, maximum/minimum/average value display, narrative display, auto power save, USB communication (optional) Use) [Display] 4-digit LCD display, max.6000dgt., bar graph [display update rate] 5 times / s (capacitance: 0.05 to 5 times / s depending on the measured value, frequency: 1 to 2 times / s , Temperature: 1 time / s) [Power supply] AAA alkaline batteries (LR03) x 4, continuous use time: 130h (when backlight is off) [Dimensions and mass] 84W x 174H x 52Dmm, 390g (including battery, horsta) [Accessories] Test lead L9207-10 x 1, Horsta x 1, Instruction Manual x 1, AAA alkaline batteries (LR03) x 4
From manufacturers
Digital multimeter


equipped with the most functions to expand the playing field Meter


Cut harmonic components, accurately measure the output voltage on the inverter secondary side


Transfer measurement data to a personal computer, check and store


True effective value measurement that can accurately measure distorted waveforms


Domestic design and manufacturing, 3-year warranty of peace of mind


A measuring instrument that is equipped with the most function is required for safe measurement
High-performance tester equipped with the most functions


the first stage of the company's first stage, which has been in business for about 40 years since its founding in 1935, and has supported the business through mass production of meters and testers.


, with the development of "internal magnetic movable coil type tote band meter", our business was developed in three directions: automation, in-home production, and standardization, and the current four product groups were built.
, we now have characteristic technologies such as metal non-contact voltage measurement technology and high sensitivity current measurement technology.


DT4256 (with most functions/10A terminals)

The "Standard Model DT4250 Series" DT4255, designed for each model for use, is one that first considers safety at electric construction sites equipped with fuses at voltage terminals.


/ DIRECT current 60.00mA / 600.0mA / 6.000A / 10.00A

/ AC clamp sensor can be connected

with power inspection function

Low pass filter function can be used to cut harmonic components and accurately measure only the fundamental wave.


connection with a PC using the dt4900-01 communication package of the same communication package, the measurement result can be displayed on the PC in real time.
can also be saved (text format) as it is.


* PC and the measuring instrument body are electrically isolated by optical communication, so they can be measured safely.


can be displayed in a graph at a specified interval time with the software attached to the communication package DT4900-01.


measurement method of digital multimeters is two, the average value method and the true effective value method.
current waveforms that are often distorted by the measurement method, the measurement results differ greatly depending on the measurement method.
be used for accurate measurement of the measurement method with a true effective value method.


's digital multimeters are developed, designed, manufactured, and all processes are carried out at the company's domestic headquarters in Nagano Prefecture.
high-quality products with the industry's top-level technical capabilities.


safe use of measuring instruments, IEC61010 classifies safety level criteria by CATII to CATIV depending on the place of use as a measurement category.
measuring with a measuring instrument that does not meet the safety level of the electric power company will lead to an electrical accident.

Shipping:
USA: 2-5 days, DHL express with Tracking number
ASIA: 2-4 weeks, Registered Air Mail with Tracking number(DHL/Fedex in some areas)
EU, UK: 2-4 weeks, Registered Air Mail with Tracking number(DHL/Fedex in some areas)
AU, CA : 1-4 weeks, DHL or Fedex(Air Mail No tracking number in some areas)

*)Depending on the destination address and type of product, the planned shipping method may be changed. If you want to know the shipping method, please contact us before purchase.
*)If you need faster shipping, please contact us before purchase.

You cannot change the destination address after making a purchase. Please make sure the shipping address is correct before making a purchase.

International Buyers - Please Note:
Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. 
Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.
These charges are normally collected by the delivering freight (shipping) company or when you pick the item up - do not confuse them for additional shipping charges. 
[DC voltage] 600.0mV to 1000V, 5 range, basic certainness: +/- 0.3% rdg. +/- 3dgt. [ALTERNATING voltage 40-500Hz] 6.000V to 1000V, 4-range, frequency characteristics: 40Hz to 1kHz, basic certainty: +/- 0.9% rdg. +/- 3dgt. (Effective value retesting, Crest factor 3 or less) [Automatic automatic discrimination] function [resistance] 600.0ohm to 60.00Mohm, 6 range, basic accuracy: +/- 0.7% rdg. +/- 3dgt. [DIRECT CURRENT]6.000A/10.00A, 4-range, Basic certainty: +/- 0.9% rdg. +/- 3dgt. [4-20mA conversion function] yes [ALTERNATING current 40-500Hz] 600.0mA to 10.00A, 3 range, basic certainty: +/- 1.4% rdg. +/- 3dgt. (Effective value retesting, Crest factor 3 or less, frequency response: 40Hz to 1kHz) [AC clamp measurement 40 to 1 kHz] 10.00A to 1000A, 7 range, basic accuracy: +/- 0.9% rdg. +/-
ISBN 4536036003068
Dimensions 84 W 174 H 52 D mm
Weight 390 g
MPN DT4256
Brand HIOKI
Power supply AAA alkaline dry battery (LR 03) 4
UPC 4536036003068
continuous use time 130 h (when backlight is turned off)
manual language Japanese
Type Digital Multimeters
Display Digital