| | 9000 BTU Ductless Mini Split AC: 19 SEER Inverter w/ 9,000 BTU Heat Pump
| Thermocore T4E19S-H209 Ductless Mini Split Heat Pump - 9000 BTU Cooling Capacity along with a 9,000 BTU Heat Pump, this 3/4 TON Ductless Split can cool or heat an area over 400 ft². 220 VAC OPERATION.Advanced INVERTER DC Technology provides both energy efficient operation and low ambient operation start-ups. Additional features include auto-diagnostic functions and sleep mode / 24 hour timer. Pre-charged with R410A and includes 15ft install Kit. | | | Features | Specifications | Installation Kit | Inverter Technology | Setup - Installation | Warranty | Shipping | Available Accessories | | |
|
|
|
Technical Data: | | System Includes: | - 9,000 BTU INVERTER Cooling Capacity
- 9,000 BTU INVERTER Heat Pump
- 19 SEER - 9.5 HSPF - AHRI Certified*
- Pre-Charged with ECO-Friendly R410A
- 1 Year Parts - 5 Year Compressor WarrantyView Details >
| | - Indoor Unit - Air Handler.
- Outdoor Unit - Compressor.
- Digital Multi-function LCD Remote Control
- Installation Kit with 15' of lineset.>
- Product and Installation Manual. >>>
|
|
|
|
Top Line Features: | - 19 SEER - 9.5 HSPF - 11 EER
- Pre-Charged w/ Eco-friendly R410A Refrigerant
- Operates on Standard 220 VAC Power Input
- Cross Flow Technology reduces noise output
- Freon Leak Detection > Notification system
- Low Ambient Temperature Operation (5° F)
- Two-direction Air vane Evenly Distributes Air
- Restart IC: Settings restored Following Outage
| |
|
| The particle filter or “pre-filter” removes dust and other air-borne pathogens before pushing the air through additional filtration medias and the refrigeration coil array. This filter is washable and comes factory installed with every ductless air conditioner system. |
| | |
| |
|
|
Model Number | Thermocore T4E19S-H209 | Compressor | TOSHIBA (GMCC) | Refrigerant | R410A (Pre-Charged) | Cooling / Heating Capacity | 9000 BTU/ 9000 BTU | Air Flow | 309/285/187 CFM | Power Supply | 220 V / 60 Hz, 1Ph | Input Power | 782W (cooling) / 925W (heating) | Rated Current | 6.8A (Cooling) / 8.1A (heating) | Maximum Fuse | 15A | Connection Wire | 16 AWG/4:standard unshielded | SEER | 19.0 | EER | 11 | HSPF4 | 9.5 | Sound Level | 38/32/35(indoor) / 52dB (outdoor) | Min Operating Temperature | - 15 C / 5 F | Net Weight | 17.2 Lbs (Indoor) / 66.8 Lbs (Outdoor) | Dimensions (WXDxH) | 28.43 x 7.36 x 11.42 in (Indoor Unit) – 30.31 x 11.81 x 21.85 in (Outdoor Unit) | Warranty | 1 Year on Parts / 5 Years on Compressor |
|
|
|
Install Kit Contents: | - 15 Feet Flared Copper Tubing
- 15 Feet Pipe Insulation
- 15 Feet Electrical Wire Harness
- Drain Pipe (Indoor)
- Indoor wall Mounting Bracket
- Remote Control Wall Bracket
- Wall Hole Block Putty & Insulated Tape
|
|
| | |
|
|
|
| | WHAT IS DC INVERTER?
DC Inverter Air Conditioners are the ultimate cooling technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.
Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained.
|
|
|
BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with R410A Freon however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning of a split AC. *Although installation may seem easy to some, certain tools and experience is necessary to complete setup of a mini split* Click for Installation Tip. It is highly advised a certified HVAC technician complete installation to be eligible for warranty. See warranty details below > | | |
|
|
*5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship.Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns.Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and a brand new exchange will be shipped out.
|
|
| | SHIPS TO TO BOTH UNITED STATES AND CANADIAN LOCATIONS! | | |
| | Our Thermocore systems ship via FedexGround or out of Warren, Michigan and will arrive in two seperate boxes. Transit time is usually between 4 to 5 business days from payment receipt depending on where you are geographically located. We do not require signature upon delivery for these shipments. We will ship to Canadian locations but please be advised of additional import brokerage charges that may be entailed when shipment crosses border. please contact our offices. |
| | |
|
|
Condenser Ground Stand |
| |
| - Provides Flat even surface - Avoids debris obstruction Price: $73.00 Click for more Info
|
| Lineset (1/4 x 3/8) |
| |
| - Required for Installation 25ft - 30ft - 40ft - 50ft Lengths Price: $38.00 > $134.00 Click for more Info |
| Condenser Bracket |
| |
| - Mount your condenser at any height on an outdoor sidewall Price: $96.00 Click for more Info
|
| Micro-Pump II |
| |
| - Required when mounting air handler on Interior wall Price: $172.00 Click for more Info
|
|
|
| Electrical Wire Harness |
| |
| - 16/4 Electrical Wire Harness - For Extending Evap. Length Price: $2.15 / ft Click for more Info
|
| Additional Remote Controls |
| |
| - Spare remote controls for the T4 Series Ductless System Price: $42.00 Click for more Info |
| Filter Medias |
| |
| - Inserts into Filter Screen Slot - Choice of 4 Filtration Medias Price: $10.00 - $14.00 Click for more Info
|
| Wired Thermostat |
| |
| - Permanently Hard Mounts - Controls Settings w/ Remote Price: $88.00 Click for more Info
|
|
|
|
|