ECG Workstation System,Portable 12-lead Resting PC based EKG Machine CONTEC8000G

CONTEC80000G WorkStation 
               

Introductions:


The device acquires functions that including synchronous sampling of conventional 12-lead ECG 

data and 3-lead vector ECG data, various forms of analysis and diagnosis, report output and other 

functions. As an integrated ECG analysis system, the devic can reflect the movement of user's heart 

timely and accurately. The device is applicable for ECG examination in medical and health institutions

 at all levels, providing accurate and reliable basis for diagnosis.

 

Features

 

1. Compact and portable design for Recorder, support Wilson and Frank lead system, with lead-off

 indicator light

2. Adopt real-time sampling, display and store mode, it has many functions, such as QRS wave 

analyzing in real-time, heart rate calculating and real-time printing, and provides multiple filter methods 

to avoid from baseline drift and interference.

3. Adopt advanced ECG analysis arithmetic, more perfect for the computer to seek points, and obtain 

reliable auto-recognizing sort of arrhythmia, which makes the analyzing report and conclusion more 

valuable.

4. ECG waveform is displayed using anti-aliasing technology clearly and intelligently, lead position can 

be adjusted, which solves the problem of overlapping waveform caused by baseline drift or high amplitude 

waveform.

5. High sampling frequency (1000Hz) ensures no distortion of ECG waveform. High resolution in display 

and printout guarantees the details of ECG waveform.

6. Provide dozens of sync and continuous display and print mode, including 6x2, 3x4, 3x4+2, etc. Auxiliary 

tool, such as superposed waveform analysis, electronic scale and editable terminology database, etc., 

brings much more convenient for diagnosis and clinical application.

7. Multiple analysis function, including: conventional 12-lead ECG, Frequency Cardiogram (FCG), High 

Frequency ECG, QT internal dispersion analysis, Heart Rate Variability (HRV) analysis, myocardium ischemia (STLE) analysis, Heart rate turbulence (HRT) analysis, Pacing ECG analysis, Vector Cardiogram (VCG), 

Time Vector Cardiogram (TVCG) and SAECG etc.

8. The "shortcut print" function can preview or print the whole analysis reports, and save them in PC with 

multimedia format (BMP, PNG, PDF or JPG format) according to factual need

9. Support calling external procedures to obtain patient information of unknown origin, export HL7 aECG 

standard format ECG data, print electronic report and send notice to external procedure, convenience for 

systems docking with hospital HIS, PACS and others.

Performance

 

HR display range: 30bpm~300bpm, error: 30bpm~100bpm, ±1bpm; 100bpm~ 300bpm, ±1%.

Sampling frequency: max. 1000Hz

Sampling accuracy: max. 24 bits

Lead: Standard 12 leads

Input loop current:≤ 0.1μA

CMRR: >60dB, >100dB (with filter)

Amplitude frequency characteristic: set 10Hz as benchmark, 0.05Hz~150Hz (-3dB~+0.4dB)

Noise level: ≤15μVp-p

Safety type: Class II Type CF with defibrillation protection


Accessories

Ground wire 1pc

ECG Workstation patch cord 2pcs

ECG Workstation data transmission line 1pc

ECG Workstation lead cable 1pc

Limb electrode clamp 1 set (4pcs)

Chest electrode 1 set (6pcs)

User manual 1pc

lead wire clip 1pc(2pcs)


Physical Characteristic

Operational environment

a) Environment temperature: 5℃~ 40℃

b) Relative humidity: 25%~ 95% (no condensation)

c) Power supply: USB DC 5V

d) Atmospheric pressure: 700hPa~1060hPa

Storage environment

a) Environment temperature: -40℃~+55℃

b) Relative humidity: ≤95%HR

c) Atmospheric pressure: 500hPa~1060hPa and portable design for Recorder, support Wilson and Frank lead system, with lead-off indicator light.



Payment:

*We accept payment from PAYPAL, Bank transfer,

Visa,Credit Card and others. 

*All payments are expected within 7 days after the last 

winning auction is closed.


Shippment


* Clearance: we will ship your item(s) to your PayPal confirmed address.Please leave me your clear  

address,telephone,postal code.

* All items will be dispatched within 2 bussiness day.

* The item will be declared as lower value for shipping only.We'd like to cooperate with you and declare the value of it 

as you want us to, so that it is more easier for you to clear the custom.


Buy safe Products

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for 
REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state 
and local regulatory agencies.If the item is subject to FDA regulation, We will verify your status as an
authorized purchaser of this item before shipping of the item. 
If you have questions about legal obligations regarding sales of medical devices, you should consult with
the FDA's Center for Devices and Radiological Health.

The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with 
the code 197923, and certified by FDA of United States and CE,TUV of Europe.The  Fingertip Pulse Oximeter that is FDA 510K Approved



About US


Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 

1992 as a high-tech company. At present there are more than 1200 employees in our company.Our product line covers 

wide range of 13 categories.Most of the domestic hospitals are our  customers.Contec hopes to cooperate with 

international companies to supply more innovative design and advanced  technology products 

We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful 

business relationship with you.

Powered by SoldEazy


Only English user guide,if you need any other language,please contact us!ibay365