Cartell CT-2BG Outdoor Control Board AC/DC w/ Enclosure & XFMR & CT-6 Prove 100ft

Cartell CT-2BG Outdoor Control Board AC/DC w/ Enclosure & XFMR & CT-6 Prove 100ft

This control unit has a single timed output and simplified features. Field adjustments include relay time and probe sensitivity.

♦ Single timed output
♦ Accommodates four sensor probes
♦ Accommodates twelve annunciators
♦ Adjustable probe sensitivity
♦ Adjustable relay time
♦ Manual trip test button
♦ Retrigger hold-off
♦ Transient suppression
♦ Case and board may be purchased separately
♦ Includes CA-5 plug-in transformer
♦ Use with CT-6 probe
♦ Accommodates sounder: CT-A1, CT-11, CT-9

Technical Specifications:

  • Power Required: 8-31 VAC or 10-41 VDC
  • Standby Current: Under 1 mA
  • Alarm Current: 45 mA maximum with one sounder (30 mA CT-GATE)
  • Relay Contact Rating: Double Pole, Double Throw
    • 1st Pole: 12 VDC, 200 mA for remotes
    • 2nd Pole: SPDT, 5 amps at 30 VDC
  • Relay Time: 1/2 to 15 Seconds
  • Temperature Range: 0F - 140F
  • Dimensions: 5.5 inches by 5.5 inches by 2 inches

*NOTE: The CT-2B and CT-2BG are identical except the CT-2BG circuit board that is conformally coated with acrylic. This coating ensures the board is not affected by a change in temperature, allowing it to be installed in unheated applications such as garages, barns and gate operators.

------------------

The CT-6-100 Sensor Probe from Cartell includes a 100' direct burial cable attached at the factory. The direct burial cable makes conduit unnecessary, allowing for easy installation.

How does the sensor probe work? The CT-6 uses magnetometer technology to detect movement in the earth's magnetic field caused by moving steel. It will not detect animals, people or blowing objects. Wind and weather do not affect it, making it virtually false-alarm proof.

Features:

  • Use with CT-2B, CF-2C and CT-3BG control units
  • Includes 100' attached direct burial cable
  • Covers a 12' wide driveway when buried beside the driveway
  • Sealed, weatherproof construction
  • Coated in a tough polyurethane for maximum protection
  • Sensor probe and wire do not require conduit
  • Maybe spliced in the field with an underground splice kit
  • Fully shielded to avoid false alarms caused by RF noise

 

Technical Specifications:

  • Temperature Range: -40F to 250F
  • Dimensions: 16 1/2" x 1 3/8" diameter
  • 500 to 800 ohms coil resistance depending on wire length