Fluke 17B+
Fluke has always been to provide you with superior quality
At work, you need a durable, reliable and accurate digital multimeter. Fluke 17B + digital multimeter can meet or exceed your needs. Common basic measurement of temperature, frequency and duty cycle measurements. Fluke 17B + easy to use, you only need one hand to operate, even when wearing gloves can also be flexible operation, can meet all your needs.
Feature:
600 V Cat III safety design specifications
50% of the display range, bright white backlight
Overvoltage indicator
Frequency and temperature measurement
Voltage, resistance, current, capacitance
Input terminal of the AC and DC current measurement value of 10 A
Diode test, data retention
Function
|
Range
|
Resolution
|
Accuracy
|
AC Voltage
(40 Hz ~ 500Hz)1
|
4.000 V
40.00 V
400.0 V
1000 V
|
0.001 V
0.01 V
0.1 V
1 V
|
1.0 % + 3
|
DC voltage
|
4.000 V
40.00 V
400.0 V
1000 V
|
0.001 V
0.01 V
0.1 V
1 V
|
0.5 % + 3
|
AC Voltage
|
400.0 mV
|
0.1 mV
|
3.0 % + 3
|
DC voltage
|
400.0 mV
|
0.1 mV
|
1.0 % + 10
|
Diode test 2
|
2.000 V
|
0.001 V
|
10%
|
Resistance
|
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
|
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
|
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
|
Capacitor 3
|
40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
|
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
|
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
|
Frequency 1
Hz
(10 Hz – 100 kHz)
|
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
|
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
|
0.1 % + 3
|
Duty Cycle 1
|
1 % 至 99 %
|
0.10%
|
1 %,典型情况4
|
AC current μA
(40 Hz ~ 400 Hz)
|
400.0 μA
4000 μA
|
0.1 μA
1 μA
|
1.5 % + 3
|
AC current mA
(40 Hz ~ 400 Hz)
|
40.00 mA
400.0 mA
|
0.01 mA
0.1 mA
|
1.5 % + 3
|
AC current A
(40 Hz ~ 400 Hz)
|
4.000 A
10.00 A
|
0.001 A
0.01 A
|
1.5 % + 3
|
DC Current μA
|
400.0 μA
4000 μA
|
0.1 μA
1 μA
|
1.5 % + 3
|
DC Current mA
|
40.00 mA
400.0 mA
|
0.01 mA
0.1 mA
|
1.5 % + 3
|
DC Current A
|
4.000 A
10.00 A
|
0.001 A
0.01 A
|
1.5 % + 3
|
Temperature
|
50 °C- 400 °C
0 °C- 50 °C
-55 °C- 0 °C
|
0.1C
|
2 % ± 1 °C
± 2 °C
9 % ± 2 °C
|
Backlight
|
-
|
-
|
有
|
1 All current, frequency and duty cycle range is range of 1% to 100%. Unspecified scale input value is less than 1%.
2 Typically, the open circuit test voltage of 2.0 V, a short circuit current of <0.6 mA.
3 Specifications do not include error test lead capacitance and capacitor plates caused (when the range of 40 nF, errors of up to 1.5 nF).
4 Usually means a frequency of 50 Hz or 60 Hz, duty cycle between 10% and 90%.
|
Case H7
The new holster is designed for Fluke 15B/17B/18B115C/116C/117C/175/177/179, F51-2/52-2/53-2/54-2.
Feature:
- There is a pocket in the case
- It is made of leather
- Shock protection
- The length:22cm, the width:15cm, the height: 8cm
Introduction:
Robust yet light and easy to carry, this refined tool leather bag brings you not only a soft and tender texture, but also an omni protection against work related dirt and liquid which can be effortlessly wiped away. With extra sponge layers support inside your bag against any possible shocks and drops, enjoy your work with no worries but joys.
Closer Look: