Specifications
Mercury thyratron TP1-6 / 15
TP1-6 / 15 mercury thyratron is designed for operation in relay and controlled converter devices of wide application (rectifiers, inverters, frequency converters).
The glow voltage is 5 V.
The glow current is from 16.5 A to 23 A.
Grid voltage unlocking - (-17.5) V.
The grid voltage locking - (-85) V.
The voltage at the anode is not more than 15 kV.
The resistance of the TP1-6 / 15 lamp grid circuit is 5 kOhm.
The run-up voltage is 25 V.
The warm-up time of the device is 15 s.
The capacitance in the grid-cathode circuit is 3000 pF.
The voltage drop between the anode and cathode is not more than 18 V.
Filling TP1-6 / 15 - mercury vapor.
Design - glass with a base RSh-15.
The cathode is an oxide of indirect heat.
Performance Limits:
- glow voltage - from 4.75 V to 5.25 V;
- anode voltage direct and reverse - 15 kV;
- grid voltage - from -500 V to 500 V;
- anode current TP1-6 / 15 (amplitude value) - 20 A;
- anode current (average value) - 6.5 A;
- resistance in the grid circuit - from 1 kOhm to 5 kOhm;
- operating frequency - 50 Hz.
Durability - at least 500 hours.
Dimensions:
- length - no more than 350 mm;
- diameter - no more than 90 mm.
Terms of Use:
Ambient temperature - from + 15 ° С to + 35 ° С.
Relative humidity at + 20 ° С - up to 98%.