【Accurate】 - NO.3000 is a precise mechanical watch testing instrument, it is used for multiple tests by watch manufacturers and watchmaking technicians.
【LCD】 - The frequency diagram of the watch can be displayed on the LCD screen. According to different watches, the instrument automatically adjusts the optimal signal level during the test.
【Professional tools】 - Automatically calculate the rate, amplitude, beat error and display them by data in real time.
【Versatile】 - The instrument can automatically adjust the signal strength according to the different watch.
【Professionals】 - Versatile Timegrapher, popular with professional watchmakers as well as the watch collection.
Feature:
【Accurate】 - NO.3000 is a precise mechanical watch testing instrument, it is used for multiple tests by watch manufacturers and watchmaking technicians.
【LCD】 - The frequency diagram of the watch can be displayed on the LCD screen. According to different watches, the instrument automatically adjusts the optimal signal level during the test.
【Professional tools】 - Automatically calculate the rate, amplitude, beat error and display them by data in real time.
【Versatile】 - The instrument can automatically adjust the signal strength according to the different watch.
【Professionals】 - Versatile Timegrapher, popular with professional watchmakers as well as the watch collection.
Specification:
Item Type: watch calibrator
Material: plastic, alloy
Voltage: 100-240 V
Measurement: flow difference, amplitude, flapping error
Flow difference measurement: the difference range is ± 999 s / day, accuracy 1.0 s / day
Amplitude measurement (digital display in degrees): the resolution is 1 °, the measurement range: 100 ° to 360 °
Measurement of the beat error (frequency error), digital display in milliseconds, the measurement range is 0 to 9.9 ms
Test items: daily difference, swing amplitude, polarization;
Measuring possibilities: Rate deviation, amplitude, beat error;
Daily difference measurement: error measurement range is ±999 seconds/day, accuracy is 1.0 second/day;
Rate deviation measurement: the range of deviation is ± 999 sec / day, precision 1.0 sec/day;
Swing measurement: digital display, resolution is 1°, measurement range is 100°—360°;
Amplitude measurement: Numerical display in degrees, resolution is1°, measuring range:100° to 360°;
Polarization (frequency error) measurement: the value is displayed in milliseconds. The resolution is 0.1 milliseconds, and the measurement range is 0-9.9 milliseconds;
Measuring for the beat error (frequency error): Numerical display in milliseconds;
Resolution is 0.1 milliseconds; the measuring range is 0-9.9 ms;
Measurement orientation: 1 to 6 orientations;
Measuring position: 1 to 6 positions;
Line Length: 320 points ;
Power supply voltage: single-phase AC 100V~240V±10%.
Package list:
1 x Testing Equipment Host
1 x Sensor
1 x Power Adapter(US/UK/EU/AU)
1 x Instruction