VENTS TwinFresh Comfo RA1-50 V.3

Power from 4.5 W
Air flow up to 50 m3/h
Sound pressure level from 13 dBA
 
- Many units can be connected to one network.
- The ventilator can operate in a passive supply mode: the air shutters are open providing a natural air flow.
The design of the unit allows easy maintenance of the ventilator.
The humidity threshold in the room can be controlled by choosing one of three modes on the remote control.
Night mode. The ventilator switches to the first speed in the dark time of the day.
Easy mounting of the mounting plate by means of magnets.

 

Operation modes:

 - Night mode 

The integrated light sensor sends a signal to switch the ventilator to low speed mode.

 - Speed switching   

 - Passive air supply 

In this mode the shutters are open, but the fan does not operate.

 - Air supply 

In this mode all ventilators will operate in supply mode irrespective of the maximum air supply setting.

 - Ventilation 

All the ventilators in the network operate in permanent air extract or air supply mode. To ensure balanced ventilation at the stage of installation it is advisable to set one half of the ventilators to air supply mode and the other part of the ventilators to air extract mode.

 - Ventilation with heat recovery 

 - Humidity control mode selection   

The ventilators can be connected into one network for centralized control. The signals from the control panel and the remote control, as well as from the humidity sensor, are received only by the master (main) ventilator. 

  • Any number of ventilators may be connected into one network.
  • Control is carried out through the first ventilator.

Maximum ease of installation – mount into the wall, plug in and use. High efficiency – up to 90 %.
Normal operation of the unit at temperatures down to -20 °C (-30 °C with a hood for a cold climate). Built-in humidity sensor for automation of unit operation.
Connecting a large number of units to the network using control cables. Control via remote control or buttons on the unit casing.
Automatic blocking off draughts by means of louver shutters when the unit is switched off. Noise from 13 to 34 dBA.
Ventilation of premises with the area of about 40 m2 (the area is approximate and depends on the ventilation standards in your country). Higher degree of supply air purification can be achieved with an F7 filter.
    Electrical fuse on the board for increased electrical safety.

 

Contact us


We can be contacted at any time through eBay messages if you have any questions, comments or product requests. We will respond to you within 24 hours and do our best to help you out! We encourage our customers to contact us with any questions or concerns! We'd like to be sure you are completely satisfied with your purchase