Introduction
The monitor is used to monitor, display, check, store, alarm and transmit many physiological parameters, including ECG (3/5/12 lead, arrhythmia analysis, ST segment analysis and HR ), RESP, SpO2, PR, NIBP, TEMP and IBP, etc. It is applicable for use by adult, children and neonate.
The monitor can be used in medical institutions or during transport monitoring inside/outside the hospital environment, it is used by clinical professionals or under their guidance or professionals via training, it is not suitable for use in family.
Function
1) 5" touch screen, easy and convenient to operate, automatic lock screen function prevents misoperation.
2) Portable design (weight < 1.0 kg), flexible to transport.
3) Multi - interface selection, convenient to observe patient’s data trend.
4) Degree of protection provided by enclosure complies with IEC/EN 60529, waterproof degree: IP44
5) Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
6) Built-in large-capacity battery, meets the requirements of long-term operation.
Performance
(1) ECG
Lead type:
3-lead: I, II, III
5-lead: I, II, III, aVR, aVL, aVF, V
12-lead: I, II, III, aVR, aVL, aVF, V1,V2,V3,V4,V5,V6
Waveform
3-lead: 1 channel
5-lead: 2-channel
10-lead: 12-channel
Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV
Scan speed: 12.5 mm/s, 25 mm/s, 50 mm/s
HR
Measurement and alarm range:
Adult: 15 ~ 300 bpm
Pediatric/neonate: 15 ~ 350 bpm
Resolution: 1 bpm
Accuracy: ± 1 % or ± 1 bpm, whichever is greater
Alarm error: ± 2 bpm
ST-segment detection
Measurement and alarm range: - 2.0 mV ~ + 2.0 mV
Accuracy: - 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater
Other range: unspecified
Arrhythmia analysis: 13 kinds
Pacemaker: yes
(2) RESP
Measurement mode: R-F (RA-LL) impedance
Respiration rate:
Measurement range: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater;
0 ~ 6 rpm, unspecified
Apnea alarm: 10 ~ 40 s
Scan speed: 12.5 mm/s, 25 mm/s
(3) NIBP
Measurement mode: Oscillometry
Working mode: Manual/AUTO/Continuous
Measurement interval in AUTO mode: 1 / 2 / 3/ 4 / 5 / 10 / 15 / 30 / 60 / 90 / 120 / 240 /480 /960 minutes
Measurement period in Continuous mode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ± 3 mmHg
Measurement accuracy:
Maximal mean deviation: ± 5 mmHg
Maximal standard deviation: 8 mmHg
Over-pressure protection:
Adult mode: 297 ± 3 mmHg
Pediatric mode: 240 ± 3 mmHg
Neonatal mode: 147 ± 3 mmHg
(4) SpO2
Measurement and alarm range: 0 ~ 100%
Resolution: 1 %
Measurement accuracy: 70 % ~ 100 %: ± 2 %;
0 % ~ 69 %: unspecified
(5) PR
Measurement and alarm range: 25 ~ 250 bpm
Accuracy: ± 2 bpm or ± 2 %, whichever is greater
(6) TEMP
Channel: dual-channel
Measurement and alarm range: 0 ~ 50 ℃
Resolution: 0.1 ℃
Accuracy: ± 0.1 ℃
(7) IBP
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measurement and alarm range: - 10 ~ 300 mmHg
Resolution: 1 mmHg
Accuracy: ± 2 % or 1 mmHg, whichever is greater
(8) Power supply: 100 ~ 240 V ~ 50 / 60 Hz (adapter output: DC 12 V)
(9) Safety class: class I, defibrillation-proof type CF applied part
(10) Waterproof degree: IP44
3.4 Accessories
Category
Accessory name
Main unit
TS1 main unit
ECG cable
5-lead, American standard, TPU
SpO2 probe (integrated)
Digital fingertip SpO2 probe for adult (CMS-N-SPO2 6P, 3M, yellow)
TEMP probe
R25=2.252K TEMP probe, skin surface type, CMS-N-TEMP 2P, PVC, L=3M
NIBP cuff
BP extension tube, L=3M
Adult cuff (25 ~ 35 cm)
3.5 Physical characteristic
Dimension: 142 mm × 67 mm × 102 mm
Weight: < 1 kg
PAYMENTBy paypal or by bank
SHIPPINGBy China : Generally, about 2-3 weeks
By Express: Generally, about 5-15 working days to UK, USA, AU and so on.
We can also ship the item through express service like DHL, UPS, if you are ready to pay the extra charge.
Terms of SaleBuy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923,and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved
Taxes, Customs & Duties
There are not extra taxes, VAT or other unmentioned payment. You pay us with goods subtotal + shipping cost (not include duties). But you need to pay for the import duties in case that occurred for certain goods.
Return - After service
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 years warranty.
2.We will refund the money to you when we get the return items or replace item for you.
ABOUT USContec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.We have us stock in IL,United States
We are looking forward to establishing a successful business relationship with you.
Welcome to be our agent.
Only english user guide,if you need any other language,please contact me.